Plan Review Details - Permit 22041468
Plan Review Stops For Permit 22041468
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By rmcphers Date 2022-06-23 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2022-06-23 Time 13:44 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 13:19 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 13:19 Sent To  
Notes
2022-05-12 13:20:06PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By rmcphers Date 2022-06-23 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2022-06-23 Time 13:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 13:20 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 11:25 Sent To  
Notes
2022-05-12 13:16:31OFFICE RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A NOTE ON THE DRAWINGS REFERRING TO
 THE FIRE CLASSIFICATION FOR THE FLOOR, WALL AND CEILING
 FINISHES - FBC CHAPTER 8
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By mpeterso Date 2022-06-24 Time 12:16 Rev Time 0.00
Received By mpeterso Date 2022-06-24 Time 12:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-05-25 Cont ID  
Sent By mpeterso Date 2022-05-25 Time 14:56 Rev Time 0.00
Received By mpeterso Date 2022-05-25 Time 14:56 Sent To  
Notes
2022-05-26 09:42:16LECTRIC REVIEW FAILED
 1) RISER DIAGRAM DETAILS #6 CU CONDUCTORS FEEDING
 PRIMARY SIDE OF 45 KVA TRANSFORMER. THE PRIMARY CURRENT
 FOR A 45KVA TRANSFORMER IS 54 AMPS. THIS LOAD IS
 CONSIDERED CONTINUOUS. CONDUCTORS FOR CONTINUOUS LOADS
 SHOULD BE SIZED AT 125% OR MINIMUM AMPACITY OF 67.5
 AMPS. NEC TABLE STATES A #4 CU CONDUCTOR TO BE USED.
 NEC 110.14(C)(1)(A)(2) AND 215.2(A)(1)(A)] PER TABLE
 310.15(B)(16).
 2) NOMENCLATURE FOR PANEL HV-10 IS DETAILED AS HP-10 ON
 PANEL SCHEDULE AND OTHER LOCATIONS. PLEASE CORRECT AS
 NEEDED. FBC 107.2
 3) PLEASE PROVIDE A COMPLETE MECHANICAL EQUIPMENT
 SCHEDULE. FBC 107.2
 4) PLEASE PROVIDE SPECIFICATIONS FOR LIGHTING INVERTER
 AND INPUT AND OUTPUT WIRING. FBC 107.2
 5) PLEASE PROVIDE A LUMINAIR SCHEDULE. FBC 107.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 2 Status P Date 2022-08-10 Cont ID  
Sent By mpeterso Date 2022-08-10 Time 11:02 Rev Time 0.00
Received By mpeterso Date 2022-08-10 Time 11:02 Sent To  
Notes
2022-08-10 11:03:15VOICE DATA AND TV

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-08-10 Cont ID  
Sent By mpeterso Date 2022-08-10 Time 10:59 Rev Time 0.00
Received By mpeterso Date 2022-08-10 Time 10:59 Sent To  
Notes
2022-08-10 11:01:55VIDEO CONFERENCING AS PER PLAN

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By pleduc Date 2022-06-13 Time   Rev Time 0.00
Received By pleduc Date 2022-06-13 Time 09:34 Sent To  
Notes
2022-06-13 09:58:35FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 ALL ACCESS CONTROL/EGRESS CONTROL/CARD READER WORK
 SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS AND COMPLY WITH NFPA 101 CH 7 MEANS OF EGRESS
 WHERE APPLICABLE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-03 Cont ID  
Sent By pleduc Date 2022-05-03 Time   Rev Time 0.00
Received By pleduc Date 2022-05-03 Time 11:22 Sent To  
Notes
2022-05-03 11:28:18FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 ALL ACCESS CONTROL/EGRESS CONTROL/CARD READER WORK
 SHALL BE SUBMITTED UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS AND COMPLY WITH NFPA 101 CH 7 MEANS OF EGRESS
 WHERE APPLICABLE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-24 Cont ID  
Sent By mpeterso Date 2022-06-24 Time 12:16 Rev Time 0.00
Received By mpeterso Date 2022-06-10 Time 10:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-25 Cont ID  
Sent By mpeterso Date 2022-05-25 Time 14:56 Rev Time 0.00
Received By mpeterso Date 2022-05-02 Time 07:02 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 13:21 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 13:21 Sent To  
Notes
2022-05-12 13:21:59NO CHANGE IN OCCUPANCY CLASSIFICATION - NO ADDED SQUARE
 FOOTAGE

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-11 Cont ID  
Sent By medwards Date 2022-06-11 Time 12:49 Rev Time 0.00
Received By medwards Date 2022-06-11 Time 12:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-05-16 Cont ID  
Sent By medwards Date 2022-05-16 Time 11:52 Rev Time 0.00
Received By medwards Date 2022-05-16 Time 11:52 Sent To  
Notes
2022-05-16 12:02:491ST REVIEW FMC
 PERMIT: 22041468
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REVISE THE PLANS TO PROVIDE THE EQUIPMENT SCHEDULE
 FOR THE EXISTING UNITS. FBC 107.2.1
  
 2) REVISE THE PLANS TO PROVIDE THE OUTDOOR AIR
 CALCULATIONS FOR EACH USE OF SPACE FOR THIS TENANT
 SPACE. FMC 403.3.1.1 AND TABLE 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
2022-05-16 11:53:25 
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By ccole Date 2022-06-13 Time 16:37 Rev Time 0.00
Received By ccole Date 2022-06-13 Time 15:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By ccole Date 2022-05-12 Time 15:27 Rev Time 0.00
Received By ccole Date 2022-05-12 Time 13:41 Sent To  
Notes
2022-05-12 15:28:291ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22041468
 5/12/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-602: SHOW THE CLEAR FLOOR SPACE DIAGRAMS
 WITH DIMENSIONS FOR THE PANTRY SINK, DISHWASHER, ICE
 MAKER AND REFRIGERATOR- SECS. 606.2, 804.6.1, 804.6.3,
 & 804.6.6 FBC ACC.
  
 2) P-001 & P-101: A MEANS OF LIMITING THE HOT WATER
 DELIVERY TEMPERATURE AT FIXTURES IS REQUIRED AND IT
 CANNOT BE A THERMOSTAT ON A WATER HEATER. A MASTER
 THERMOSTATIC OR POINT OF USE MIXING VALVE SHALL BE
 INSTALLED- SEC. 607.1.1 FBC P. PLEASE DO NOT CONFUSE
 THE CODE REQUIREMENT WITH THE TEMPERED WATER DELIVERY
 REQUIREMENT FOR PUBLIC LAVATORIES. HOT WATER AT A
 MINIMUM OF 110 DEGREES F IS REQUIRED AT THE SINK AND
 DISHWASHER- SEC. 607.1.
  
 3) P-001: THE FIRESTOPPING DETAIL DOES NOT APPEAR TO BE
 A UL TESTED AND APPROVED ASSEMBLY REQUIRED FOR PIPES
 PENETRATING THROUGH THE FLOOR SLABS- SECS. 315.1 FBC P
 AND 714.4.1.2 FBC B.
  
 4) G-900 & P-101: PLEASE SHOW THE WATER SUPPLY PIPING
 TO THE DISHWASHER & ICE MAKER- SEC. 602.1 FBC P.
 INDICATE HOW DRAINAGE FROM THE UNITS WILL BE DISCHARGED
 INDIRECTLY AND CONVEYED TO APPROVED PLACES OF DISPOSAL-
 SEC. 802.1 FBC P.
  
 5) P-101: PROVIDE BACKFLOW PREVENTERS AT THE INDIVIDUAL
 WATER SUPPLY LINES TO THE COFFEE MAKER AND REFRIGERATOR
 ICE MAKER- SEC. 608.3 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By rmcphers Date 2022-06-23 Time 13:46 Rev Time 0.00
Received By rmcphers Date 2022-06-23 Time 13:46 Sent To  
Notes
2022-06-11 12:52:15MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 13:30 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 13:30 Sent To  
Notes
2022-05-12 13:35:17SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) ARCHITECTURAL DRAWINGS NEED TO BE SIGNED AND SEALED
 BY THE DESIGNER FBC WPB 107.1
  
 2) ARCHITECTURAL DRAWINGS DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE A VERIFIABLE ELECTRONIC OR DIGITAL SIGNATURE -
 YOU CAN DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  