Plan Review Details - Permit 22041417
Plan Review Stops For Permit 22041417
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-04-27 Cont ID  
Sent By cpuell Date 2022-04-27 Time 14:29 Rev Time 0.00
Received By cpuell Date 2022-04-27 Time 14:29 Sent To  
Notes
2022-04-27 13:08:47OWNER UPDATE

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-09-29 Cont ID  
Sent By pvalenti Date 2022-09-29 Time 16:33 Rev Time 0.00
Received By pvalenti Date 2022-09-29 Time 16:28 Sent To  
Notes
2022-09-29 16:43:01PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 ADDITIONAL PERMITS ARE REQUIRED FOR DEMOLITION AND FOR
 SITE-WALL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-09-14 Cont ID  
Sent By pvalenti Date 2022-09-14 Time 07:49 Rev Time 0.00
Received By pvalenti Date 2022-09-14 Time 07:49 Sent To  
Notes
2022-09-14 07:51:22PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 ADDITIONAL PERMITS ARE REQUIRED FOR DEMOLITION AND
 SITE-WALL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-08-05 Cont ID  
Sent By pvalenti Date 2022-08-05 Time 10:31 Rev Time 0.00
Received By pvalenti Date 2022-08-04 Time 16:41 Sent To  
Notes
2022-08-05 10:34:31PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW APPROVED WITH PROVISO:
  
 ADDITIONAL PERMITS ARE REQUIRED FOR SITEWALL AND FOR
 DEMOLITION.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-06-11 Cont ID  
Sent By pvalenti Date 2022-06-11 Time 11:02 Rev Time 0.00
Received By pvalenti Date 2022-06-09 Time 10:10 Sent To  
Notes
2022-06-11 11:51:02PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1.) FBC R 806.5, PLEASE PROVIDE SPECIFIC DETAILS FOR
 THE UNVENTED AIR SPACES, AS IT APPEARS THAT ICENYNE IS
 TO BE USED FOR THE UNDERSIDE OF ROOF SHEATHING
 INSULATION. PER CODE SECTION FBC R 806.5 THERE ARE
 SEVERAL OPTIONS TO BE USED DEPENDING ON ALL OF THE
 PROPOSED AND EXISTING VARIABLES INCLUDING THE AIR
 PERMIABILITY OF THE INSULATION.
 2.) FBC B 107.2.1, PLEASE PROVIDE A DRAINAGE PLAN FOR
 THE SITE.
 3.) FBC B 107.2.1, PROVIDE CONFIRMATION OF A SITE WALL
 PERMIT.
 4.) FBC B 107.2.1, PROVIDE DETAILS FOR A STORM WATER
 PREVENTION PLAN DURING CONSTRUCTION.
 5.) FBC B 107.2.1, PROVIDE CONFIRMATION IF ONE OF THE
 APPROVED ROLL OFF/FRANCHISE HAULERS WILL BE USED FOR
 REMOVAL OF DEBRIS.
 6.) FBC B 107.2.1, IT APPEARS THAT THERE IS AN EXISTING
 ONE STORY BUILDING AND EXTERIOR SECTIONS OF OTHER
 STRUCTURES THAT ARE TO BE DEMILISHED. IF THIS IS
 ACCURATE, PROVIDE CONFIRMATION OF A DEMO PERMIT.
 7.) FBC R 311 & R 312, PROVIDE LOCATION AND DETAILS FOR
 HANDRAILS AND GUARDS ON PLAN SHEETS.
 8.) FBC B 107.3.4.1, PLEASE LIST ALL OF THE PROPOSED
 DEFERRED SUBMITTALS(PRODUCT APPROVALS & SHOP DRAWINGS)
 ON PLAN SHEETS. PLEASE INCLUDE: HANDRAILS, & PERGOLA.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-17 Cont ID  
Sent By mpeterso Date 2022-05-17 Time 10:33 Rev Time 0.00
Received By mpeterso Date 2022-05-17 Time 10:32 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 5 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 10:46 Rev Time 0.00
Received By ccole Date 2022-10-04 Time 09:47 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 4 Status F Date 2022-09-26 Cont ID  
Sent By rwbrown Date 2022-09-26 Time 08:19 Rev Time 0.00
Received By rwbrown Date 2022-09-26 Time 08:19 Sent To  
Notes
2022-09-26 08:22:024TH GAS REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC G2415.8.1 - THE CONDUIT FOR THE GAS SLEEVE
 TO THE FIREPLACE MUST TERMINATE IN AN "OCCUPIABLE
 PORTION" OF THE BUILDING. BEHIND AN ACCESS PANEL IS NOT
 "OCCUPIABLE". CONSIDER USING ANOTHER PORTION OF THE
 BUILDING FOR THE SLEEVE TO ENTER THE STRUCTURE AND THEN
 CONTINUING OVERHEAD FOR THE REMAINDER OF THE RUN.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2022-09-01 Cont ID  
Sent By ccole Date 2022-09-01 Time 13:02 Rev Time 0.00
Received By ccole Date 2022-09-01 Time 07:50 Sent To  
Notes
2022-09-01 13:02:343RD REVIEW FBC-2020 RES. GAS
 PERMIT- 22041417
 9/1/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P-1 & P-4: THE TRACPIPE CSST PS-II
 PRE-SLEEVED GAS PIPING IS APPROVED FOR
 UNDERGOUND/UNDERSLAB INSTALLATION, HOWEVER THE SLEEVED
 PIPE AND VENT PORT SHALL TERMINATE IN OCCUPIABLE
 PORTIONS OF THE BUILDING PER SEC. G2415.8.1 FBC RES
 (404.14.1 FBC FG). THE SLEEVE SHALL EXTEND A MINIMUM OF
 2-INCHES INTO THE SPACE. THE RESUBMITTED PLAN APPEARS
 TO SHOW THE TERMINATIONS INSIDE THE WALLS ADJACENT TO
 THE FIREPLACE AND THE RANGE.
  
 A) PLEASE NOTE THAT THE AC CLOSET ADJACENT TO THE
 FIREPLACE CANNOT BE THE OCCUPIABLE SPACE FOR
 TERMINATION BECAUSE IT IS A PLENUM CLOSET- SEC. G2415.3
 FBC RES (404.3 FBC FG).
  
 B) CONCERNING THE RANGE, THE SLEEVED TRACPIPE SHALL
 TERMINATE MINIMUM 2-INCHES ABOVE THE FLOOR BEHIND THE
 RANGE OR IN AN ADJACENT CABINET. PLEASE NOTE A FLEXIBLE
 CONNECTOR IS REQUIRED FOR THE RANGE.
  
 2) M-1: IN RESPONSE TO COMMENT #8 FROM THE 1ST GAS
 REVIEW, THE ENGINEER IS SPECIFYING A TYPE B FLUE VENT
 SYSTEM WHICH IS NOT APPROVED FOR USE BY THE
 MANUFACTURER- SEC. G2427.2.1 FBC RES. PLEASE SEE PAGE
 21 OF THE CRAVE 4836 HEATILATOR INSTALLATION MANUAL FOR
 APPROVED FLUE VENT- HEARTH & HOME TECHNOLOGIES DVP
 VENTING SYSTEMS. PLEASE NOTE B VENTS ARE TYPICALLY USED
 FOR NATURAL DRAFT APPLIANCES- SEE TABLE G2427.4 FBC
 RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-07-14 Cont ID  
Sent By ccole Date 2022-07-14 Time 11:17 Rev Time 0.00
Received By ccole Date 2022-07-14 Time 10:44 Sent To  
Notes
2022-07-14 11:28:10 
 2ND REVIEW FBC-2020 RES. GAS
 PERMIT- 22041417
 7/14/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. THERE WERE NO CORRECTIONS
 TO THE PLANS OR RESPONSES PROVIDED TO ADDRESS THE 1ST
 REVIEW COMMENTS PRINTED BELOW. PLEASE COMPLY WITH THE
 COMMENTS. PLEASE NOTE THAT GAS CAN BE UNDER A SEPARATE
 PERMIT IF REQUESTED.
  
 1) SHEETS P1 & P4: NOTE 9 ON P1 INDICATES A 2 PSI
 REGULATOR, THE RISER ON P4 SHOWS A 0.5 PSI REGULATOR-
 WHICH IS IT?
  
 2) P1 & P4: PIPING TO THE GAS DRYER NOT SHOWN- SEC.
 G413.1 FBC RES.
  
 3) P1, P2, P4: REFER TO SECS. G2411.1 & G2411.2-
 G2411.3 AND PROVIDE ELECTRICAL BONDING DETAILS AND
 NOTES FOR THE METALLIC AND CSST PIPING.
  
 4) P1 & P3: PER NOTE #18 PLEASE REFER TO SEC. G2415.14
 AND INDICATE THE TYPE AND SIZE OF FACTORY SLEEVE AND
 SUBMIT SPECIFICATIONS FOR THE SLEEVE TO VERIFY LISTING
 COMPLIANCE. PLEASE NOTE THAT COMPLETE INSTALLATION
 GUIDELINES FOR THE CSST PIPING SHALL BE SUBMITTED FOR
 REVIEW, OR CAN BE A DEFERRED SUBMITTAL- SEC. G2425.5.4
 FBC RES AND 107.3.4.1 WPB.
  
 5) P1 & P3: PER NOTE #18 PROVIDE A VENT PORT DETAIL FOR
 THE CSST SLEEVES AND INDICATE HOW THE SLEEVES WILL BE
 SEALED AT THE TERMINATION LOCATIONS INSIDE THE
 BUILDING- SEC. G2415.8.1 FBC RES.
  
 6) P1 & P3: PROVIDE TANKLESS WATER HEATER CONDENSATE
 DISPOSAL PLANS INCLUDING INSTALLATION OF THE
 MANUFACTURER'S RECOMMENDED NEUTRALIZING DEVICE PER SEC.
 G2408.1 FBC RES. INCLUDE THE SPECS FOR THE DEVICES IN
 THE EQUIPMENT SCHEDULE AND MODIFY THE DRAWINGS TO SHOW
 TYPE AND SIZE OF PIPING, PIPING RUN AND DISCHARGE
 LOCATIONS- SECS. 307.2-307.3 FBC FG.
  
 7) P1 & P3: SHOW THE REQUIRED INSTALLATION CLEARANCES
 FOR THE GAS WATER HEATERS- SECS. G2427.1 & G2448.1 FBC
 RES.
  
 7) P1 & P4 GAS RANGE: SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE NEW RANGE THAT SHOW THE BTU GAS
 LOAD, INPUT PRESSURE, AND LISTING OF THE APPLIANCE-
 SEC. G2447.1 FBC RES. A) PROVIDE COMBUSTION AIR
 CALCULATIONS FOR THE RANGE- SEC. G2407.1 FBC RES.
  
 8) P1 & P4 GAS FIREPLACE: PROVIDE A DIRECT VENTING
 DIAGRAM SHOWING THE TYPES AND SIZES OF AIR INLET AND
 EXHAUST VENT DUCTS, DUCT RUNS AND TERMINATION
 LOCATIONS- SEC. SUBMIT SPECS FOR THE VENT DUCTS-
 G2427.2.1 & G2427.8 ITEM #3 FBC RES.
  
 9) P1 & P4 BBQ: SUBMIT COMPLETE SPECIFICATIONS AND
 INSTALLATION MANUAL FOR THE BBQ GRILL- G2448.1 FBC RES.
 THE SPECS SHALL SHOW THE BTU LOAD, GAS INPUT PRESSURE,
 CLEARANCES TO COMBUSTIBLE AND OVERHEAD CONSTRUCTION,
 COMBUSTION AIR AND VENTILATION, AND EXHAUST VENTING
 GUIDELINES. PLEASE NOTE THAT AN EXHAUST HOOD AND DUCT
 SYSTEM MAY BE REQUIRED- SEC. G2448.1 FBC RES. PROVIDE
 PLAN DETAILS THAT REFLECT THE INSTALL MANUAL
 RECOMMENDATIONS AND RESTRICTIONS. A) SHOW THE CLEARANCE
 DISTANCES FROM THE GRILL EXHAUST TO GRAVITY AND
 MECHANICAL AIR INTAKES INTO THE BUILDING- SEC. R303.5.1
 FBC RES. MINIMUM 10 FT. CLEARANCES REQUIRED.
  
 10) P1 &P4 GAS DRYER: THE GAS DRYER SUBMITTAL IS
 INCOMPLETE. PROVIDE COMPLETE SPECIFICATIONS AND
 INSTALLATION GUIDELINES- G2438.1 FBC RES. THE SPECS
 SHALL SHOW THE BTU LOAD, INPUT PRESSURE AND SHOW
 GUIDELINES FOR COMBUSTION AIR, MAKEUP, AND EXHAUST
 VENTING. PROVIDE DETAILS ON THE PLAN IN ACCORDANCE WITH
 THE SPECS AND SEC. G2439.1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-05-06 Cont ID  
Sent By ccole Date 2022-05-06 Time 11:05 Rev Time 0.00
Received By ccole Date 2022-05-06 Time 06:52 Sent To  
Notes
2022-05-06 11:07:18 
 1ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22041417
 5/6/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1 & P4: NOTE 9 ON P1 INDICATES A 2 PSI
 REGULATOR, THE RISER ON P4 SHOWS A 0.5 PSI REGULATOR-
 WHICH IS IT?
  
 2) P1 & P4: PIPING TO THE GAS DRYER NOT SHOWN- SEC.
 G413.1 FBC RES.
  
 3) P1, P2, P4: REFER TO SECS. G2411.1 & G2411.2-
 G2411.3 AND PROVIDE ELECTRICAL BONDING DETAILS AND
 NOTES FOR THE METALLIC AND CSST PIPING.
  
 4) P1 & P3: PER NOTE #18 PLEASE REFER TO SEC. G2415.14
 AND INDICATE THE TYPE AND SIZE OF FACTORY SLEEVE AND
 SUBMIT SPECIFICATIONS FOR THE SLEEVE TO VERIFY LISTING
 COMPLIANCE. PLEASE NOTE THAT COMPLETE INSTALLATION
 GUIDELINES FOR THE CSST PIPING SHALL BE SUBMITTED FOR
 REVIEW, OR CAN BE A DEFERRED SUBMITTAL- SEC. G2425.5.4
 FBC RES AND 107.3.4.1 WPB.
  
 5) P1 & P3: PER NOTE #18 PROVIDE A VENT PORT DETAIL FOR
 THE CSST SLEEVES AND INDICATE HOW THE SLEEVES WILL BE
 SEALED AT THE TERMINATION LOCATIONS INSIDE THE
 BUILDING- SEC. G2415.8.1 FBC RES.
  
 6) P1 & P3: PROVIDE TANKLESS WATER HEATER CONDENSATE
 DISPOSAL PLANS INCLUDING INSTALLATION OF THE
 MANUFACTURER'S RECOMMENDED NEUTRALIZING DEVICE PER SEC.
 G2408.1 FBC RES. INCLUDE THE SPECS FOR THE DEVICES IN
 THE EQUIPMENT SCHEDULE AND MODIFY THE DRAWINGS TO SHOW
 TYPE AND SIZE OF PIPING, PIPING RUN AND DISCHARGE
 LOCATIONS- SECS. 307.2-307.3 FBC FG.
  
 7) P1 & P3: SHOW THE REQUIRED INSTALLATION CLEARANCES
 FOR THE GAS WATER HEATERS- SECS. G2427.1 & G2448.1 FBC
 RES.
  
 7) P1 & P4 GAS RANGE: SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE NEW RANGE THAT SHOW THE BTU GAS
 LOAD, INPUT PRESSURE, AND LISTING OF THE APPLIANCE-
 SEC. G2447.1 FBC RES. A) PROVIDE COMBUSTION AIR
 CALCULATIONS FOR THE RANGE- SEC. G2407.1 FBC RES.
  
 8) P1 & P4 GAS FIREPLACE: PROVIDE A DIRECT VENTING
 DIAGRAM SHOWING THE TYPES AND SIZES OF AIR INLET AND
 EXHAUST VENT DUCTS, DUCT RUNS AND TERMINATION
 LOCATIONS- SEC. SUBMIT SPECS FOR THE VENT DUCTS-
 G2427.2.1 & G2427.8 ITEM #3 FBC RES.
  
 9) P1 & P4 BBQ: SUBMIT COMPLETE SPECIFICATIONS AND
 INSTALLATION MANUAL FOR THE BBQ GRILL- G2448.1 FBC RES.
 THE SPECS SHALL SHOW THE BTU LOAD, GAS INPUT PRESSURE,
 CLEARANCES TO COMBUSTIBLE AND OVERHEAD CONSTRUCTION,
 COMBUSTION AIR AND VENTILATION, AND EXHAUST VENTING
 GUIDELINES. PLEASE NOTE THAT AN EXHAUST HOOD AND DUCT
 SYSTEM MAY BE REQUIRED- SEC. G2448.1 FBC RES. PROVIDE
 PLAN DETAILS THAT REFLECT THE INSTALL MANUAL
 RECOMMENDATIONS AND RESTRICTIONS. A) SHOW THE CLEARANCE
 DISTANCES FROM THE GRILL EXHAUST TO GRAVITY AND
 MECHANICAL AIR INTAKES INTO THE BUILDING- SEC. R303.5.1
 FBC RES. MINIMUM 10 FT. CLEARANCES REQUIRED.
  
 10) P1 &P4 GAS DRYER: THE GAS DRYER SUBMITTAL IS
 INCOMPLETE. PROVIDE COMPLETE SPECIFICATIONS AND
 INSTALLATION GUIDELINES- G2438.1 FBC RES. THE SPECS
 SHALL SHOW THE BTU LOAD, INPUT PRESSURE AND SHOW
 GUIDELINES FOR COMBUSTION AIR, MAKEUP, AND EXHAUST
 VENTING. PROVIDE DETAILS ON THE PLAN IN ACCORDANCE WITH
 THE SPECS AND SEC. G2439.1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-06-01 Cont ID  
Sent By fmittner Date 2022-06-01 Time 12:50 Rev Time 0.00
Received By fmittner Date 2022-06-01 Time 12:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2022-10-04 Time   Rev Time 0.00
Received By lmarchan Date 2022-10-03 Time 16:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-09-29 Cont ID  
Sent By pvalenti Date 2022-09-29 Time 16:33 Rev Time 0.00
Received By pvalenti Date 2022-09-23 Time 09:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-09-14 Cont ID  
Sent By shill Date 2022-09-14 Time 15:21 Rev Time 0.00
Received By shill Date 2022-08-31 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-16 Cont ID  
Sent By aoliver Date 2022-08-16 Time 08:48 Rev Time 0.00
Received By aoliver Date 2022-07-13 Time 06:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-11 Cont ID  
Sent By pvalenti Date 2022-06-11 Time 12:50 Rev Time 0.00
Received By pvalenti Date 2022-05-05 Time 07:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-10-04 Cont ID  
Sent By lmarchan Date 2022-10-04 Time 08:29 Rev Time 0.00
Received By lmarchan Date 2022-10-03 Time 16:07 Sent To  
Notes
2022-10-04 08:29:54RECEIPT MU-2022-042088 - $546.52 PAID
2022-10-03 16:08:0910/3/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-06-11 Cont ID  
Sent By pvalenti Date 2022-06-11 Time 12:18 Rev Time 0.00
Received By pvalenti Date 2022-06-11 Time 12:18 Sent To  
Notes
2022-06-11 12:20:42PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-09-01 Cont ID  
Sent By medwards Date 2022-09-01 Time 08:30 Rev Time 0.00
Received By medwards Date 2022-09-01 Time 08:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-07-14 Cont ID  
Sent By medwards Date 2022-07-14 Time 08:05 Rev Time 0.00
Received By medwards Date 2022-07-14 Time 08:05 Sent To  
Notes
2022-07-14 08:05:462ND REVIEW FMC
 PERMIT: 22041417
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ENERGY CALCULATIONS SUBMITTED THIS CYCLE SHOWS
 ON PAGE 2 THAT THERE ARE 3 AHU?S FOR THE HOUSE AND THE
 COTTAGE. AHU-1 IS FOR 1166 SQUARE FEET AND CONDITIONS
 THE LIVING-DINING. AHU-2 IS FOR 1102 SQUARE FEET AND
 CONDITIONS THE MASTER-KITCHEN. AHU-3 IS FOR 300 SQUARE
 FEET AND CONDITIONS THE COTTAGE. NOTHING ON PAGE 2 OF
 THE ENERGY CALCULATIONS INDICATES THE GARAGE AS BEING
 CONDITIONED. THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS SPECIFIES 5 UNITS FOR THE PROJECT WHICH
 INCLUDES THE HOUSE, GARAGE AND CABANA. THE AHU?S LISTED
 ON THE EQUIPMENT SIZING CALCULATIONS ARE- AHU-1, AHU-2,
 AHU-3, AHU-4 AND AHU-5. SHEET M-1 AND M-2 LISTS AHU-1A,
 AHU-B, AHU-2A, AHU-2B AND AHU-3
 PLEASE PROVIDE DOCUMENTS THAT ARE CONSISTENT WITH EACH
 OTHER. PLEASE ALSO PROVIDE AN ENERGY CALCULATIONS THAT
 SHOWS THE MECHANICAL SYSTEMS CONSISTENT WITH THE
 MECHANICAL SIZING CALCULATIONS AND THE MECHANICAL
 DRAWINGS.
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By medwards Date 2022-05-09 Time 16:58 Rev Time 0.00
Received By medwards Date 2022-05-09 Time 16:58 Sent To  
Notes
2022-05-09 16:58:531ST REVIEW FMC
 PERMIT: 22041417
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THERE ARE 2 ENERGY CALCULATIONS SUBMITTED PLEASE
 REMOVE ONE SO THAT WE ONLY HAVE ONE. YOU CAN EMAIL THE
 PERMIT LIBRARIAN AND ASK THEM TO LOCK THE ONE THAT
 WOULD NOT APPLY. FBC 107
  
 2) PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FEC R403.7.1
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 5 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 10:47 Rev Time 0.00
Received By ccole Date 2022-10-04 Time 09:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-09-26 Cont ID  
Sent By rwbrown Date 2022-09-26 Time 08:15 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-09-01 Cont ID  
Sent By rwbrown Date 2022-09-01 Time 07:36 Rev Time 0.00
Received By rwbrown Date 2022-09-01 Time 07:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-07-14 Cont ID  
Sent By ccole Date 2022-07-14 Time 11:29 Rev Time 0.00
Received By ccole Date 2022-07-14 Time 10:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-06 Cont ID  
Sent By ccole Date 2022-05-06 Time 09:09 Rev Time 0.00
Received By ccole Date 2022-05-06 Time 06:52 Sent To  
Notes
2022-05-06 09:10:391ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 22041417
 5/6/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1- P4: A SEPARATE PERMIT IS REQUIRED FOR THE
 PROPOSED BATH/CABANA SEC. 107.2.1 WPB.
  
 2) P1- P4: TWO DWELLING UNITS ON THE SAME LOT
 (MULTI-FAMILY) REQUIRES INSTALLATION OF AN RPZ BACKFLOW
 PREVENTER IN ACCORDANCE WITH SECTION E. TABLE 1.1 WPB
 UTILITIES CROSS-CONNECTION MANUAL. THE PROPOSED POOL
 AND IRRIGATION SYSTEM EACH UNDER SEPARATE PERMIT WILL
 ALSO TRIGGER THE NEED FOR THE BACKFLOW UNDER SEC. D. E.
 AND TABLE 1.1. THE BACKFLOW INSTALLATION SHALL BE DONE
 UNDER A SEPARATE PERMIT. PLEASE PROVIDE A NOTE ON THE
 PLAN SHOWING COMPLIANCE WILL BE MET- SECS. 105.1 &
 107.2.1 WPB.
  
 A FL. LICENSED PLUMBING CONTRACTOR SHALL OBTAIN A
 SEPARATE PERMIT FOR INSTALLATION OF THE BACKFLOW
 PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB AND SEC.
 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL BE
 TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION'
  
 3) P1 & P2: PROVIDE A CLEANOUT AT THE JUNCTION OF THE
 CABANA BUILDING DRAIN/SEWER- SEC. P3005.2.3 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2022-09-29 Cont ID  
Sent By pvalenti Date 2022-09-29 Time 16:30 Rev Time 0.00
Received By pvalenti Date 2022-09-29 Time 16:28 Sent To  
Notes
2022-09-29 16:30:43PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ROOFING REVIEW APPROVED:
  
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF
 WORK.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-08-05 Cont ID  
Sent By pvalenti Date 2022-08-05 Time 10:28 Rev Time 0.00
Received By pvalenti Date 2022-08-04 Time 16:41 Sent To  
Notes
2022-08-05 10:30:20PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ROOFING REVIEW APPROVED:
  
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF
 WORK.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-06-11 Cont ID  
Sent By pvalenti Date 2022-06-11 Time 12:08 Rev Time 0.00
Received By pvalenti Date 2022-06-11 Time 12:08 Sent To  
Notes
2022-06-11 12:17:07PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 ROOFING REVIEW DENIED:
  
 1.) FBC B 107.2.1, PROVIDE ON PLANS THE ROOFING
 MATERIAL (PRODUCT APPROVALS) THAT WILL BE USED.
 2.) FBC TABLE R 905.1.1, IT APPEARS THAT DUE TO THE
 ROOF SLOPE TWO LAYERS OF ROOFING UNDERLAYMENT WILL BE
 REQUIRED. PLEASE INDICATE THAT INFORMATION ON ROOFING
 PLAN SHEETS.
 NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ROOF
 WORK.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 11:02 Rev Time 0.00
Received By ccole Date 2022-10-04 Time 09:47 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-09-29 Cont ID  
Sent By pvalenti Date 2022-09-29 Time 16:31 Rev Time 0.00
Received By pvalenti Date 2022-09-29 Time 16:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-09-29 Cont ID  
Sent By pvalenti Date 2022-09-14 Time 07:58 Rev Time 0.00
Received By pvalenti Date 2022-09-14 Time 07:51 Sent To  
Notes
2022-09-14 08:01:45SIGNATURE REVIEW DENIED:
  
 THE STRUCTURAL PLAN SHEETS NEED TO HAVE A THIRD PARTY
 VERIFIABLE SIGNATURE BY ENGINEER.
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-08-03 Cont ID  
Sent By rwbrown Date 2022-08-03 Time 06:07 Rev Time 0.00
Received By rwbrown Date 2022-08-03 Time 06:07 Sent To  
Notes
2022-08-03 06:07:50ALL PAGES ARE NOT ELECTRONICALLY SIGNED/SEALED
  
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-06-10 Cont ID  
Sent By pvalenti Date 2022-06-10 Time 13:54 Rev Time 0.00
Received By pvalenti Date 2022-06-09 Time 10:10 Sent To  
Notes
2022-06-10 13:54:03SIGNATURE REVIEW DENIED:
  
 THE MAJORITY OF PLAN SHEETS ARE SCANS OF DIGITAL
 SIGNATURES. THESE PLAN SHEETS DO NOT HAVE 3RD PARTY
 VERIFIED DIGITAL SIGNATURES. PLEASE REVIEW AND SUBMIT
 WITH 3RD PARTY VERIFIABLE DIGITAL SIGNATURES.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  
2022-05-09 16:59:34DIGITAL SIGNATURES FOR THE MECHANICAL DOCUMENTS
 APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-09-01 Cont ID  
Sent By fmittner Date 2022-09-01 Time 15:41 Rev Time 0.00
Received By fmittner Date 2022-09-01 Time 15:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-08-15 Cont ID  
Sent By fmittner Date 2022-08-15 Time 11:32 Rev Time 0.00
Received By fmittner Date 2022-08-15 Time 11:32 Sent To  
Notes
2022-08-15 11:35:18COMMENTS FROM FIRST REVEIW NOT ADDRESSED.

Review Stop Z ZONING
Rev No 1 Status F Date 2022-06-01 Cont ID  
Sent By ahamilto Date 2022-06-01 Time 12:51 Rev Time 0.00
Received By fmittner Date 2022-06-01 Time 12:51 Sent To  
Notes
2022-06-01 12:51:33REQUIRES A SEPERATE LANDSCPE PERMIT, DRIVEWAY PERMIT,
 MECHANICAL PERMIT