| Plan Review Stops For Permit 22041407 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-24 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-24 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-30 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-30 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2022-06-30 15:03:31 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1 & FBC B 107.2.6, PROVIDE A SURVEY & | | | SITE-PLAN SHOWING THE LOCATION WITH SET-BACK | | | MEASUREMENTS. | | | | | | FBC B 107.2.1, PLEASE PROVIDE THE ANCHORING TO | | | FOUNDATION SPECIFICATIONS SIGNED & SEALED BY A DESIGN | | | PROFESSIONAL TO MEET THE WINDLOAD RESISTANCE. | | | NOTE: THE STRUCTURE ITSELF HAS BEEN APPROVED BY | | | MANUFACTURER'S INSPECTION. (STILL NEED FOUNDATION/TIE | | | DOWN APPROVAL). |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-08-24 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-08-03 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-30 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-04-28 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-09-02 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-09-02 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-09-02 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2022-09-02 10:31:04 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW APPROVED AS THIS IS A STATE APPROVED | | | STRUCTURE AND TIE DOWN/FOOTING PLANS HAVE BEEN | | | SIGNED/SEALED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-03 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-03 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2022-08-03 17:04:21 | ALL SIGNATURES AND SEALS ARE PHOTOCOPIES. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-30 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-30 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2022-06-30 15:06:09 | SIGNATURE REVIEW DENIED: | | | | | | PROVIDE ANCHORING/TIE-DOWN TO FOUNDATION SPECIFICATIONS | | | SIGNED/SEALED BY A DESIGN PROFESSIONAL. | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-09 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-09 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-05-09 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-05-09 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2022-05-09 09:43:57 | 05/09/22 FAILED- NEED TO SHOW WHERE THE SHED WILL BE | | | PLACED ON THE PROPERTY. PLEASE PROVIDE A SURVEY AND | | | INCLUDE SETBACK AND BUILDING SEPERATION MEASUREMENTS. | | | IVE COPIED THE REQUIREMENTS BELOW | | | | | | SETBACKS. | | | FRONT: 25 FEET. | | | | | | SIDE: FIVE FEET FROM THE LOT LINES. | | | | | | CORNER: SAME AS REQUIRED FOR PRINCIPAL STRUCTURE. | | | | | | REAR: FIVE FEET MINIMUM OR 15 FEET FROM THE CENTERLINE | | | OF THE ALLEY TO A GARAGE DOOR FACING THE ALLEY, | | | WHICHEVER IS GREATER. | | | | | | BUILDING SEPARATION. ACCESSORY STRUCTURES COVERED WITH | | | A SOLID ROOF SHALL BE LOCATED NO CLOSER THAN SIX FEET | | | TO THE PRINCIPAL STRUCTURE. ACCESSORY STRUCTURES LESS | | | THAN SIX FEET FROM THE PRIMARY STRUCTURE MUST MEET THE | | | PRIMARY STRUCTURE SETBACKS. ACCESSORY STRUCTURES MAY BE | | | CONNECTED TO THE PRINCIPAL STRUCTURE WITH A CANVAS | | | COVERED OPEN BREEZEWAY. | | | | | | | | | ALEXANDER FOWLKES | | | [email protected] | | | 5618221431 |
|
|