Plan Review Details - Permit 22041384
| Plan Review Stops For Permit 22041384 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-16 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-16 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-05-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-10 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-10 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-05-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-05-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-05-02 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-05-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-05-18 |
Time |
06:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-16 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-28 |
Time |
13:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-16 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-16 |
Time |
17:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2022-05-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-19 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-19 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-16 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-16 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2022-05-16 13:05:12 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22041384 | | | 5/16/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P-002 & P-412: EWH-2 SHOWN IN RESTROOM DETAIL | | | 1 HAS BEEN REMOVED FROM THE EQUIPMENT SCHEDULE- SEC. | | | 107.2.1 WPB. | | | | | | 2) P-602: SANITARY FIXTURE AND BRANCH DRAIN PIPINGS FOR | | | THE NEW HD AND FD-2 NOT SHOWN IN THE ISOMETRIC DRAWING- | | | SEC. 107.2.1 WPB. | | | | | | 3) P-602: PLEASE CLARIFY WHY THE FLOOR DRAINS WERE | | | CHANGED TO HUB DRAINS.- SEC. 107.2.1 WPB. WERE THE TRAP | | | PRIMERS REQUIRED FOR EMERGENCY FLOOR DRAINS STILL TO BE | | | USED OR REMOVED?- THEY ARE REQUIRED- SEC. 1002.4.1 FBC | | | P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-05-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-20 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-20 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2022-05-20 09:19:56 | UPLOADED NEW DIG/SIG SHEETS P-412 & P-602 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-05-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-19 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-19 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2022-05-19 08:14:06 | SIGNATURE REVIEW | | | 5/19/2022 | | | | | | 1) SHEETS P-412 & P-602 APPEAR TO HAVE SCANNED AND | | | COPIED DIGITAL SEALS AND SIGNATURES. PLEASE NOTE THAT | | | ELECTRONICALLY TRANSMITTED PLANS SHALL BEAR DIGITAL | | | SIGNATURES AND SEALS THAT ARE CAPABLE OF BEING | | | VERIFIED- FL. STATUTE 471.025, AND SECTION 61G15-23.005 | | | FAC. | | | | | | FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR | | | ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND | | | DOCUMENTS. | | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | | USE A THIRD PARTY. | | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | | AND DOCUMENT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-05-16 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-16 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-16 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |