Plan Review Details - Permit 22041219
Plan Review Stops For Permit 22041219
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2022-07-20 Cont ID  
Sent By shill Date 2022-07-20 Time 09:33 Rev Time 0.00
Received By shill Date 2022-07-20 Time 09:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-06-24 Cont ID  
Sent By ppetty Date 2022-06-24 Time 09:47 Rev Time 0.00
Received By ppetty Date 2022-06-24 Time 09:47 Sent To  
Notes
2022-06-24 09:48:15NO ELECTRICAL ON PLAN

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-27 Cont ID  
Sent By vbroglia Date 2022-07-27 Time 12:39 Rev Time 0.00
Received By vbroglia Date 2022-07-21 Time 07:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-20 Cont ID  
Sent By shill Date 2022-07-20 Time 09:33 Rev Time 0.00
Received By shill Date 2022-06-06 Time 09:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-07-26 Cont ID  
Sent By ccole Date 2022-07-26 Time 10:18 Rev Time 0.00
Received By ccole Date 2022-07-26 Time 09:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-14 Cont ID  
Sent By ccole Date 2022-06-14 Time 14:35 Rev Time 0.00
Received By ccole Date 2022-06-14 Time 11:31 Sent To  
Notes
2022-06-14 14:39:111ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22041219
 6/14/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GENERAL CONTRACTOR KOLOSVARY MANAGEMENT CONSULT
 FOR THE R3 HEATH & MED HOUSE (PERMIT- 21110622) WAS
 INFORMED DURING THE BUILD-OUT REVIEW THAT THE FLOAT SPA
 REQUIRES AN OPERATING PERMIT ISSUED BY THE DEPARTMENT
 OF HEALTH. IT WAS ACKNOWLEDGED THAT UNDER THE SEPARATE
 PERMIT FOR THE SPA, A COPY OF THE DOH RECEIPT WOULD BE
 PROVIDED ALONG WITH THE COPY OF THE DOH VARIANCE FOR
 THE SPA AND THE SPA ROOM. THE VARIANCE PROVIDES A LIST
 OF CODE FBC COMPLIANCES NOT REQUIRED AND A LIST OF
 THOSE THAT ARE REQUIRED. THE PLANS SHALL REFLECT ALL
 COMPLIANCES LISTED IN THE VARIANCE APPROVAL- FAC 64E-9,
 SEC. 454.1 FBC B, AND SEC. 107.2.1 WPB.
  
 2) THE PLUMBING PLANS ARE NOT ACCEPTABLE FOR REVIEW
 BECAUSE THEY ARE MARKED-UP COPIES OF THE PLUMBING
 ENGINEER?S PLANS FOR THE TENANT BUILD-OUT- SEC. 107.2.1
 WPB. PLEASE RESUBMIT DIGITALLY SIGNED AND SEALED PLANS
 BY THE ENGINEER OF RECORD, OR THE CONTRACTOR CAN SUBMIT
 PLANS BEARING HIS/HER PRINTED NAME AND SIGNATURE- FL.
 STATURES 471.003(2)(H) & 471.025, SEC. 61G15-23.005
 FAC.
  
 3) SUBMIT MANUFACTURER?S SPECIFICATIONS AND
 INSTALLATION MANUAL FOR THE FLOAT SPA- SEC. 107.2.1
 WPB.
  
 4) PLEASE PROVIDE ENLARGED PLUMBING DIAGRAMS INDICATING
 HOW WATER WILL BE SUPPLIED TO THE SPA, AND HOW WASTE
 WATER WILL BE DRAINED TO AN APPROVED PLACE OF DISPOSAL-
 SECS- 454.1.8.1, 454.1.6.5.11, & 454.1.6.5.15 FBC B.
 PLEASE NOTE THAT WASTE WATER FROM THE SPA SHALL NOT
 DRAIN INTO THE CITY SANITARY SYSTEM IN ACCORDANCE WITH
 SEC. 90-126(5) WPB CODE OF ORDINANCES. PLEASE REVIEW
 THE FOLLOWING GUIDELINES-
  
 SWIMMING POOL WATER SHALL NOT BE DISCHARGED TO SANITARY
 SEWER WITHOUT PRIOR APPROVAL FROM THE PUBLIC UTILITIES
 DEPARTMENT.
 SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY
 STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED
 ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM
 BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER?S
 SPECIFICATION FOR THE DICHLORINATION SYSTEM FOR REVIEW
 AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL
 WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED:
 THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH TO
 KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE
 INLET).
 NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE
 INLET TO DISCHARGE EFFLUENT.
 WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE ALLOWED
 TO FILTER THROUGH GRASS AREA ON THE POOL OWNERS
 PROPERTY BEFORE DISCHARGING ON CITY PROPERTY.
 DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING
 PROPERTY.
 FOR TECHNICAL QUESTIONS, DON'T HESITATE TO CONTACT O&M
 SUPERINTENDENT STEPHON HARRIS AT [email protected] OR
 561-822-2168.
 FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE
 CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE
 SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561)
 822-2062 OR [email protected].
  
 5) PLEASE NOTE A BACKFLOW PREVENTER WILL BE REQUIRED IF
 A WATER SUPPLY LINE IS DIRECTLY CONNECTED TO THE SPA-
 SEC. 608.17.4.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2022-07-26 Cont ID  
Sent By ccole Date 2022-07-26 Time 10:18 Rev Time 0.00
Received By ccole Date 2022-07-26 Time 09:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-07-08 Cont ID  
Sent By ccole Date 2022-07-08 Time 10:29 Rev Time 0.00
Received By ccole Date 2022-07-08 Time 10:29 Sent To  
Notes
2022-07-08 10:33:571ST REVIEW FBC-2020 SIGNATURE
 PERMIT- 22041219
 6/14/2022
  
 CODES IN EFFECT:
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE PLUMBING PLANS ARE NOT ACCEPTABLE FOR REVIEW
 BECAUSE THEY ARE MARKED-UP COPIES OF THE PLUMBING
 ENGINEERS' PLANS FOR THE TENANT BUILD-OUT- SEC. 107.2.1
 WPB. PLEASE RESUBMIT ORIGINAL, DIGITALLY SIGNED AND
 SEALED PLANS BY THE ENGINEER OF RECORD, OR THE
 CONTRACTOR CAN SUBMIT PLANS BEARING HIS/HER PRINTED
 NAME AND SIGNATURE- FL. STATURES 471.003(2)(H) &
 471.025, SEC. 61G15-23.005 FAC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-07-27 Cont ID  
Sent By vbroglia Date 2022-07-27 Time 12:39 Rev Time 0.00
Received By vbroglia Date 2022-07-27 Time 12:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-06-14 Cont ID  
Sent By vbroglia Date 2022-06-14 Time 15:39 Rev Time 0.00
Received By vbroglia Date 2022-06-14 Time 15:39 Sent To  
Notes
***NONE***