Plan Review Details - Permit 22041189
| Plan Review Stops For Permit 22041189 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-07-24 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-07-24 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-07-03 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-07-03 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2023-07-03 13:32:44 | COMMERCIAL ASBESTOS | | | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING | | | THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS | | | PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM | | | BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION | | | WILL BE GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-02-28 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-28 16:41:14 | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTORS LETTERHEAD, STATING THAT | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-12-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-12-14 |
Time |
14:57 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2022-12-14 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-14 14:57:50 | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING | | | THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS | | | PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM | | | BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION | | | WILL BE GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-07-03 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-07-03 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2023-07-03 13:23:03 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22041189 | | | ADD: 2032 N DIXIE HWY. | | | CONT: SOLID ROCK RENOVATION | | | TEL: 561-577-3057 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: TUES. 7-03-23 | | | ACTION: DENIED | | | 1-4) COMPLIED, WINDOW & DOOR PERMIT 23030707. 2020 | | | FBC-B 1603.1.4 WIND DESIGN CRITERIA. | | | | | | 5) SHEET COVERSHEET. SCOPE OF WORK, COMMENTS: | | | | | | 5A) 3RD REQUEST. SEMI-COMPLIED, NOTE # 2 INDICATES NEW | | | VINYL FLOORING, PLEASE DESIGNATE THE LOCATIONS OF | | | FLOORING REQUIRING UNDERLAYMENT IN THE 2ND STORY | | | RESIDENTIAL UNITS AND MAIN CORRIDOR AND OVER THE 1ST | | | FLOOR RESIDENTIAL OCCUPANCIES. 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1. | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES. A WRITTEN ANALYSIS | | | NEEDS TO ACCOMPANY THE PLANS AS TO HOW YOU ARE GOING TO | | | ACHIEVE BOTH AN IIC & STC RATING OF 50 OR MORE. THE | | | SHEET A-3 SHOWS A FLOOR CEILING ASSEMBLY GA FILE FC5250 | | | THAT SHOW A STC RATING OF 45 TO 49 DB RATING. THE SAME | | | HOLDS TRUE FOR THE WALL RATING BETWEEN THE R2 TENANT | | | SPACES FOR BOTH THE 1ST FLOOR UNITS AND WALL RATING FOR | | | THE 2ND FLOOR R2 OCCUPANCIES BOTH FLOOR SYSTEM AND WALL | | | SYSTEMS NEED TO ACHIEVE A MINIMUM OF 50 DB FOR IIC & | | | STC RATINGS. SEE COMMENTS 5A & 5B. | | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND | | | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND | | | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING | | | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH | | | OF THE STANDARDS FOR A WOOD FLOOR JOIST SYSTEM 6-INCH | | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR BUILDINGS | | | SHOWING COMPLIANCE WITH: | | | | | | 5A)(1) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | | | 5B)(2) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | | 90. | | | | | | 5C)(3) COMPLIED 1 HOUR FIRE RATING ASSEMBLY FOR | | | FLOORING AND WALL ASSEMBLIES. | | | 5B) COMPLIED, GA ASSOCIATION 1 HOUR FIRE RATING | | | ASSEMBLIES FOR WALLS AND FLOORS. | | | | | | 5B)(1) COMPLIED, GA ASSOCIATION 1 HOUR FIRE RATING | | | ASSEMBLIES FOR WALLS AND FLOORS. | | | | | | 5B)(2) 3RD REQUEST. SEE COMMENT 5A. BETWEEN DWELLING | | | UNITS. FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | | 90. | | | | | | 6) COMPLIED. | | | | | | 7) SEMI-COMPLIED, THE CONTRACTOR HAS SUBMITTED WHERE | | | THEY WILL MEET THEIR DISPROPORTIONATE COST IN THE 1ST | | | FLOOR RESTROOM. 2ND REQUEST PROVIDE LETTER ON EITHER | | | THE DESIGN PROFESSIONAL OR CONTRACTOR LETTER HEAD WHERE | | | THESE FUNDS ARE TO BE SPENT. FIRST FLOOR. FLORIDA | | | ACCESSIBILITY CODE SECTION: DISPROPORTIONATE COST | | | 202.4.1. PLEASE REVIEW HOW YOU ARE TO MEET | | | DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR THE | | | DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW HOW | | | THEY ARE GOING TO SPEND UP TO THE 20% DISPROPORTIONATE | | | FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING | | | SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 | | | DISPROPORTIONATE COST OF THE 2020 ACCESSIBILITY CODE. | | | SHEET A-2 STILL MISSING ACCESSIBLE ELEMENTS IN THE | | | ELEVATION VIEWS: | | | A) CLEAR FLOOR SPACE DIAGRAM & DIMENSIONS FOR THE WATER | | | CLOSET. SECTION 604.3 | | | B) CLEAR FLOOR SPACE DIAGRAM & DIMENSIONS FOR THE | | | LAVATORIES. SECTION 606.2. | | | C) TURNING SPACE DIAMETERS. SECTION 304.3 | | | D) TOILET FLUSH CONTROL SECTION 604.6 FLUSH CONTROLS TO | | | BE LOCATED OPEN SIDE OF WATER CLOSET. | | | E) CENTERLINES OF THE TOILET DISPENSER MEASURED FROM | | | THE FRONTS OF THE WATER CLOSET. SECTION & FIGURE 604.7 | | | F) HEIGHT OF THE MIRRORS FROM THE FINISHED FLOORS TO | | | THE BOTTOM EDGE OF THE REFLECTIVE SURFACE, MIRRORS | | | ABOVE SINKS. SECTION 606.3. | | | 202.4.1. DISPROPORTIONATE COST. ALTERATIONS MADE TO | | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | | ALTERATION TO THE PRIMARY FUNCTION AREA. COST THAT MAY | | | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN | | | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COST | | | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN | | | ACCESSIBLE ROUT TO THE ALTERED AREA; (II) COST | | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | | ENLARGING DOOR OPENINGS, INSTALLING GRAB BARS, | | | ENLARGING TOILET STALLS, INSULATING PIPES, OR | | | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COST | | | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH | | | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, | | | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT | | | TELEPHONE (TTY); (IV) COST ASSOCIATED WITH RELOCATING | | | AN ACCESSIBLE DRINKING FOUNTAIN. | | | | | | 8) COMPLIED. | | | | | | 9) A NEW ARCHITECTURAL CANOPY HAS BEEN SUBMITTED, THERE | | | IS NO LOCATION WHERE THIS IS TO BE INSTALLED, NO | | | ENGINEERING SHEET NOR WIND LOAD OR FASTENING | | | SCHEDULENOR HEIGHT OF THE BOTTOM OF CANOPY ABOVE | | | GROUND, PROVIDE A SURVEY WITH LOCATION SHOWN ON THE | | | SURVEY A SEPARATE PERMIT IS REQUIRED, PROVIDE VALUE FOR | | | CANOPY. . 2020 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.2.1. CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. | | | | | | 10) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-02-28 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-02-28 16:39:16 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22041189 | | | ADD: 2032 N DIXIE HWY. | | | CONT: SOLID ROCK RENOVATION | | | TEL: 561-577-3057 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. 2/28/2023 | | | ACTION: DENIED | | | 1) 2ND REQUEST. STOP WOK ORDERS WERE GIVEN ON 4/19/22 | | | FOR ALL TRADES, 8/23/22 STOP WORK ORDER WAS GIVEN FOR | | | GAS WORK WITHOUT THE BENEFIT OF A PERMIT. WORK NOT | | | INCLUDED IN THE SCOPE OF WORK NEW WINDOWS SHOWN ON | | | GOGGLE MAPS. 2 PERMITS WERE REVOKED 12030175 REPLACE 3 | | | EXT. DOORS, 15070290 REVOKED VALUE $350.00 DOLLARS | | | REPLACE BROKEN WINDOWS, 15010327 REISSUE 1212703 FOR | | | REPLACE 3 EXTERIOR DOORS. NONE OF THESE PERMITS | | | INDICATE NEW WINDOWS FOR THE 2ND STORY PLEASE INCLUDE | | | IN THE SCOPE OF WORK. PLEASE PROVIDE THE FOLLOWING | | | INFORMATION: | | | 2) 2ND REQUEST. 2020 FBC-B 1603.1.4 WIND DESIGN | | | CRITERIA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS | | | DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. | | | | | | 2. RISK CATEGORY. | | | | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1. | | | | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED | | | BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR | | | THE DESIGN OF THE STRUCTURE, PSF. | | | | | | 6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED | | | CONVERSION VULT TO VASD. | | | | | | 3) 2ND REQUESST. COMPONENTS & CLADDING. PLEASE SUBMIT | | | THE COMPONENTS AND CLADDING PRODUCT APPROVALS. 2020 | | | FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 | | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(B) WINDOWS & MULLIONS | | | | | | 4) 2ND REQUEST. W. P. B. 107.3.4. PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY FLORIDA | | | ADMINISTRATIVE CODE RULE 61G20 SHALL BE REVIEWED AND | | | APPROVED IN WRITING (SHOP DRAWING STAMP OF APPROVAL) BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC. | | | | | | 5) SHEET COVERSHEET. SCOPE OF WORK, COMMENTS: | | | 5A) 2ND REQUEST. NOTE # 2 INDICATES NEW VINYL FLOORING, | | | PLEASE DESIGNATE THE LOCATIONS OF FLOORING IN | | | RESIDENTIAL UNITS, 2ND STORY CORRIDOR AND STAIRS AND OR | | | 1ST FLOOR BUSINESS OCCUPANCIES. 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1. | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES. | | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND | | | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND | | | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING | | | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH | | | OF THE STANDARDS FOR A 6-INCH CONCRETE FLOOR ASSEMBLY/ | | | NO DROPPED CEILING: | | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | | | 5A)(1) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | | | 5B)(2) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | | 90. | | | | | | 5C)(3) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. | | | (TILE & MARBLE) INSULATION INSTALLED BETWEEN A FINISHED | | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | OR | | | 5C)(3) FBC-B 804.4.4.1 SOFT FLOOR FINISHES (LVT/ LPT OR | | | LAMINATED OR ENGINEERED WOOD FLOORING) WITHIN TENANT | | | SPACE. INTERIOR FLOOR COVERING MATERIALS SHALL COMPLY | | | WITH THE REQUIREMENTS OF THE COC FF-1 ???PILL TEST??? | | | (CPSC 16 CFR PART 1630) OR WITH ASTM D2859. | | | LVT & LPT LUXURY VINYL TILE. FLOOR FINISH | | | CLASSIFICATION AS REQUIRED IN SECTION 804.2 | | | CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF | | | THE 2020 FBC-B. 804.2 & 804.3/ ASTM E648 OR NFPA 253 | | | | | | 5B) SEMI-COMPLIED SHOW AREAS WHERE TO BE REPLACED. | | | NOTES 3 & 4 DEAL WITH REPLACEMENT OF DRYWALL BOTH 1/2 | | | INCH AND 5/8-INCH TYPE X EXACT LOCATIONS ARE NOT GIVEN | | | NOR THE AMOUNT OF DRYWALL THAT IS TO BE INSTALLED. 2020 | | | WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1. DRAWINGS & | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO | | | THE TECHNICAL CODES. | | | | | | 5B)(1)THE PLANS ARE SILENT AS TO MAINTAINING 1-HOUR | | | FIRE RATING SEE 2020 FBC-BUILDING CODE 420.2 SEPARATION | | | WALLS AND 420.3 HORIZONTAL SEPARATION. FIRE RATED | | | CORRIDORS AND STAIRWAY SECTION 1023.2, SECTION 707 AND | | | OR SECTION 711. 1-HOUR FIRE RATING FOR BENEATH THE | | | STAIRWAY 1011.7.3. 1ST FLOOR STOCKROOM. | | | | | | 5B)(2) BETWEEN DWELLING UNITS. FBC-B 2020 1207.2 | | | AIR-BORNE SOUND. WALLS, PARTITIONS AND FLOOR/CEILING | | | ASSEMBLIES SEPARATING DWELLING UNITS FROM EACH OTHER OR | | | FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND | | | TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 IF | | | FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 90. | | | | | | 5C) 2ND REQUEST. PROVIDE LOCATIONS WHERE WOOD IS | | | DAMAGED OR ROTTEN, IT IS UP TO THE DESIGN PROFESSIONAL | | | TO GIVE THE CONTRACTORS DIRECTION, IF BEYOND YOUR SCOPE | | | THEN AN ENGINEER SHOULD GET INVOLVED. NOTE 5 INDICATES | | | REPLACE EXISTING DAMAGED FRAMING OR ROTTEN FRAMING | | | ENCOUNTERED PER THE PRESCRIPTIVE METHOD OF THE EXISTING | | | BUILDING CODE. PLEASE READ THE SECTIONS 401.2.2 AND | | | 401.2.2. IN BOTH CASES SUCH MATERIALS SHALL BE | | | DETERMINED BY THE BUILDING OFFICIAL TO BE UNSAFE. AGAIN | | | PLEASE PROVIDE THE AREAS WHERE DAMAGED OR ROTTEN | | | FRAMING MEMBERS ARE LOCATED SIZE OF FRAMING MEMBERS, | | | SPACING, SPANS, TYPE OF EXISTING FRAMING AND TYPE OF | | | PROPOSED FRAMING, IF TO BE REMOVED, OR IF TO BE | | | SISTERED AND THE LENGTH OF THE SISTERED FRAMING MEMBER | | | VERSE THE OLD FRAMING MEMBER. PLEASE ALSO REVIEW IN THE | | | 2020 EXISTING BUILDING CODE 401.3 DANGEROUS CONDITIONS. | | | THE BUILDING OFFICIAL SHALL HAVE THE AUTHORITY TO | | | REQUIRE THE ELIMINATION OF CONDITIONS DEEMED DANGEROUS. | | | | | | 6) 2ND REQUEST, THE DESIGN PROFESSIONAL GIVES DIRECTION | | | TO AMOUNT OF DOORS SO THE CONTRACTOR KNOWS HOW TO BID | | | THE PROJECT. NOTE 6 STATES THE GC SHALL REPLACE | | | EXISTING INTERIOR DAMAGED INTERIOR DOORS. PLEASE | | | PROVIDE LOCATIONS OF THESE DOORS, IF ENTRY DOORS INTO | | | THE R2 RESIDENTIAL UNITS THEN THEY SHALL COMPLY WITH | | | FBC-BUILDING TABLE 1020.1. | | | | | | 7) 2ND REQUEST PROVIDE LETTER ON EITHER THE DESIGN | | | PROFESSIONAL OR CONTRACTOR LETTER HEAD WHERE THESE | | | FUNDS ARE TO BE SPENT. FIRST FLOOR. FLORIDA | | | ACCESSIBILITY CODE SECTION: DISPROPORTIONATE COST | | | 202.4.1. PLEASE REVIEW HOW YOU ARE TO MEET | | | DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR THE | | | DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW HOW | | | THEY ARE GOING TO SPEND UP TO THE 20% DISPROPORTIONATE | | | FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING | | | SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 | | | DISPROPORTIONATE COST OF THE 2020 ACCESSIBILITY CODE. | | | | | | 202.4.1. DISPROPORTIONATE COST. ALTERATIONS MADE TO | | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | | ALTERATION TO THE PRIMARY FUNCTION AREA. COST THAT MAY | | | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN | | | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COST | | | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN | | | ACCESSIBLE ROUT TO THE ALTERED AREA; (II) COST | | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | | ENLARGING DOOR OPENINGS, INSTALLING GRAB BARS, | | | ENLARGING TOILET STALLS, INSULATING PIPES, OR | | | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COST | | | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH | | | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, | | | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT | | | TELEPHONE (TTY); (IV) COST ASSOCIATED WITH RELOCATING | | | AN ACCESSIBLE DRINKING FOUNTAIN. | | | | | | 8) 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION ON 06/2020. IN BATHROOMS, RESTROOMS & | | | SERVICE SINK AREAS EPOXY PAINT IS NO LONGER CONSIDERED | | | A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | | | 8A) 2ND REQUEST. PLEASE STATE WHAT TYPE OF TILE BACKING | | | BOARD IS TO BE INSTALLED IN RESTROOMS & BATHROOMS | | | THROUGHOUT THE PROJECT. | | | 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF SERVICE | | | SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS | | | THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A | | | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | | | | 10) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-12-21 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-12-14 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2022-12-21 08:19:34 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22041189 | | | ADD: 2032 N DIXIE HWY. | | | CONT: SOLID ROCK RENOVATION | | | TEL: 561-577-3057 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. 12/21/2022 | | | ACTION: DENIED | | | 1) STOP WOK ORDERS WERE GIVEN ON 4/19/22 FOR ALL | | | TRADES, 8/23/22 STOP WORK ORDER WAS GIVEN FOR GAS WORK | | | WITHOUT THE BENEFIT OF A PERMIT. WORK NOT INCLUDED IN | | | THE SCOPE OF WORK NEW WINDOWS SHOWN ON GOGGLE MAPS. 2 | | | PERMITS WERE REVOKED 12030175 REPLACE 3 EXT. DOORS, | | | 15070290 REVOKED VALUE $350.00 DOLLARS REPLACE BROKEN | | | WINDOWS, 15010327 REISSUE 1212703 FOR REPLACE 3 | | | EXTERIOR DOORS. NONE OF THESE PERMITS INDICATE NEW | | | WINDOWS FOR THE 2ND STORY PLEASE INCLUDE IN THE SCOPE | | | OF WORK. PLEASE PROVIDE THE FOLLOWING INFORMATION: | | | 2) 2020 FBC-B 1603.1.4 WIND DESIGN CRITERIA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS | | | DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. | | | | | | 2. RISK CATEGORY. | | | | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1. | | | | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED | | | BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR | | | THE DESIGN OF THE STRUCTURE, PSF. | | | | | | 6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED | | | CONVERSION VULT TO VASD. | | | 3) COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS | | | AND CLADDING PRODUCT APPROVALS. 2020 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & | | | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, | | | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ | | | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(B) WINDOWS & MULLIONS | | | | | | 4) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP | | | DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD | | | PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC. | | | | | | 5) SHEET COVERSHEET. SCOPE OF WORK, COMMENTS: | | | 5A) NOTE # 2 INDICATES NEW VINYL FLOORING, PLEASE | | | DESIGNATE THE LOCATIONS OF FLOORING IN RESIDENTIAL | | | UNITS, 2ND STORY CORRIDOR AND STAIRS AND OR 1ST FLOOR | | | BUSINESS OCCUPANCIES. 2020 WEST PALM BEACH AMENDMENTS | | | TO THE FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.2.1. | | | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN | | | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF | | | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY | | | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE | | | SPECIFIC TO THE TECHNICAL CODES. | | | 5B) NOTES 3 & 4 DEAL WITH REPLACEMENT OF DRYWALL BOTH | | | ?? INCH AND 5/8-INCH TYPE X EXACT LOCATIONS ARE NOT | | | GIVEN NOR THE AMOUNT OF DRYWALL THAT IS TO BE | | | INSTALLED. 2020 WEST PALM BEACH AMENDMENTS TO THE | | | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION | | | 107.2.1. DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | | SHALL BE SPECIFIC TO THE TECHNICAL CODES. | | | THE PLANS ARE SILENT AS TO MAINTAINING 1-HOUR FIRE | | | RATING SEE 2020 FBC-BUILDING CODE 420.2 SEPARATION | | | WALLS AND 420.3 HORIZONTAL SEPARATION. FIRE RATED | | | CORRIDORS AND STAIRWAY SECTION 1023.2, SECTION 707 AND | | | OR SECTION 711. 1 HOUR FIRE RATING FOR BENEATH THE | | | STAIRWAY 1011.7.3. 1ST FLOOR STOCKROOM. | | | | | | 5C) NOTE 5 INDICATES REPLACE EXISTING DAMAGED FRAMING | | | OR ROTTEN FRAMING ENCOUNTERED PER THE PRESCRIPTIVE | | | METHOD OF THE EXISTING BUILDING CODE. PLEASE READ THE | | | SECTIONS 401.2.2 AND 401.2.2. IN BOTH CASES SUCH | | | MATERIALS SHALL BE DETERMINED BY THE BUILDING OFFICIAL | | | TO BE UNSAFE. AGAIN PLEASE PROVIDE THE AREAS WHERE | | | DAMAGED OR ROTTEN FRAMING MEMBERS ARE LOCATED SIZE OF | | | FRAMING MEMBERS, SPACING, SPANS, TYPE OF EXISTING | | | FRAMING AND TYPE OF PROPOSED FRAMING, IF TO BE REMOVED, | | | OR IF TO BE SISTERED AND THE LENGTH OF THE SISTERED | | | FRAMING MEMBER VERSE THE OLD FRAMING MEMBER. PLEASE | | | ALSO REVIEW IN THE 2020 EXISTING BUILDING CODE 401.3 | | | DANGEROUS CONDITIONS. THE BUILDING OFFICIAL SHALL HAVE | | | THE AUTHORITY TO REQUIRE THE ELIMINATION OF CONDITIONS | | | DEEMED DANGEROUS. | | | | | | 6) NOTE 6 STATES THE GC SHALL REPLACE EXISTING INTERIOR | | | DAMAGED INTERIOR DOORS. PLEASE PROVIDE LOCATIONS OF | | | THESE DOORS, IF ENTRY DOORS INTO THE R2 RESIDENTIAL | | | UNITS THEN THEY SHALL COMPLY WITH FBC-BUILDING TABLE | | | 1020.1. | | | | | | 7) FIRST FLOOR. FLORIDA ACCESSIBILITY CODE SECTION: | | | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU | | | ARE TO MEET DISPROPORTIONATE COST. EITHER THE | | | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR | | | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP | | | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH | | | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE | | | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST | | | OF THE 2020 ACCESSIBILITY CODE. | | | | | | 202.4.1. DISPROPORTIONATE COST. ALTERATIONS MADE TO | | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | | ALTERATION TO THE PRIMARY FUNCTION AREA. COST THAT MAY | | | BE COUNTED AS EXPENDITURES REQUIRED TO PROVIDE AN | | | ACCESSIBLE PATH OF TRAVEL MAY INCLUDE: (I) COST | | | ASSOCIATED WITH PROVIDING AN ACCESSIBLE ENTRANCE AND AN | | | ACCESSIBLE ROUT TO THE ALTERED AREA; (II) COST | | | ASSOCIATED WITH MAKING RESTROOMS ACCESSIBLE, SUCH AS | | | ENLARGING DOOR OPENINGS, INSTALLING GRAB BARS, | | | ENLARGING TOILET STALLS, INSULATING PIPES, OR | | | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COST | | | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH | | | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, | | | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT | | | TELEPHONE (TTY); (IV) COST ASSOCIATED WITH RELOCATING | | | AN ACCESSIBLE DRINKING FOUNTAIN. | | | | | | 8) 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS | | | COMMENT IS A RESULT OF THE BUILDING OFFICIAL | | | INTERPRETATION ON 06/2020. IN BATHROOMS, RESTROOMS & | | | SERVICE SINK AREAS EPOXY PAINT IS NO LONGER CONSIDERED | | | A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | | | 8A) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF | | | SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A | | | SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT | | | LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL | | | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A | | | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | | | | 9) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-07-17 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-07-17 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2023-07-17 13:41:10 | ELECTROCAL REVIEW FAILED | | | | | | IT APPEARS NONE OF THE PRIOR COMMENTS HAVE BEEN | | | ADDRESSED. PROVIDE A WRITTEN NARRITIVE ADDRESSING EACH | | | OF THE PRIOR 11 COMMENTS, ALONG WITH CORRECTED PLANS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-10 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-10 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2023-03-10 12:27:31 | ELECTRIC REVIEW FAILED | | | | | | 1) PLEASE PROVIDE A COMPLETE RISER DIAGRAM. INCLUDE ALL | | | EQUIPMENT, CONDUIT, WIREWAY, CONDUCTOR, SIZES AND | | | NUMBER OF CONDUCTORS IN ALL RACE WAYS AND WIREWAYS. NEC | | | 215.5 | | | | | | NEC 215.5 DIAGRAMS OF FEEDERS. IF REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, A DIAGRAM SHOWING FEEDER | | | DETAILS SHALL BE PROVIDED PRIOR TO THE INSTALLATION OF | | | THE FEEDERS. | | | | | | 2 ) IT APPEARS THERE ARE MULTIPLE CONDUCTORS IN | | | CONDUITS BETWEEN WIREWAYS THAT WILL NEED TO BE DE RATED | | | AS REQUIRED PER NEC 310.15(B)(3). | | | | | | 310.15(B)(3). ADJUSTMENT FACTORS. MORE THAN THREE | | | CURRENT-CARRYING CONDUCTORS. WHERE THE NUMBER OF | | | CURRENT-CARRYING CONDUCTORS IN A RACEWAY OR CABLE | | | EXCEEDS THREE, OR WHERE SINGLE CONDUCTORS OR | | | MULTICONDUCTOR CABLES ARE INSTALLED WITHOUT MAINTAINING | | | SPACING FOR A CONTINUOUS LENGTH LONGER THAN 600 MM (24 | | | IN.) AND ARE NOT INSTALLED IN RACEWAYS, THE ALLOWABLE | | | AMPACITY OF EACH CONDUCTOR SHALL BE REDUCED AS SHOWN IN | | | TABLE 310.15(B)(3)(A) | | | | | | 3) PLEASE RESPOND TO PREVIOUS COMMENT. THE EXISTING | | | ELECTRICAL SERVICE WAS PERMITTED AS 300-AMP. YOU DETAIL | | | THE EXISTING SERVICE AS 400 AMP. PLEASE RESOLVE THIS | | | CONFLICT. FBC 107.2 | | | | | | FBC 107.2 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. | | | | | | 4) PLEASE DETAIL ELECTRIC WORK THAT IS EXISTING AND TO | | | REMAIN AND WORK THAT IS NEW AND TO BE ADDED ON ALL | | | ELECTRIC PLANS. FBC 107.2 | | | | | | 5) PLEASE DETAIL THE HVAC RECEPTACLES REQUIRED ON THE | | | ROOF. NEC 210.63 | | | | | | NEC 210.63 HEATING, AIR-CONDITIONING, AND REFRIGERATION | | | EQUIPMENT OUTLET. A 125-VOLT, SINGLE-PHASE, 15- OR | | | 20-AMPERE-RATED RECEPTACLE OUTLET SHALL BE INSTAL???LED | | | AT AN ACCESSIBLE LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING, | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET | | | SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE | | | EQUIPMENT DISCONNECTING MEANS. | | | | | | 6) DETAIL REQUIRED OUTSIDE RECEPTACLES AT OUTSIDE | | | PORCHES AND ON THE SECOND FLOOR IF THEY ARE ACCESSIBLE | | | FROM DWELLING UNITS. NEC 210.52 (E)(2) AND NEC (E)(3) | | | | | | NEC 210.52(2) MULTIFAMILY DWELLINGS. FOR EACH DWELLING | | | UNIT OF A MULTIFAMILY DWELLING WHERE THE DWELLING UNIT | | | IS LOCATED AT GRADE LEVEL AND PROVIDED WITH INDIVIDUAL | | | EXTERIOR ENTRANCE/EGRESS, AT LEAST ONE RECEPTACLE | | | OUTLET READILY ACCESSIBLE FROM GRADE AND NOT MORE THAN | | | 2.0 M (61???2 FT) ABOVE GRADE LEVEL SHALL BE INSTALLED | | | | | | NEC 210. (E)(3) BALCONIES, DECKS, AND PORCHES. | | | BALCONIES, DECKS, AND PORCHES THAT ARE ATTACHED TO THE | | | DWELLING UNIT AND ARE ACCESSIBLE FROM INSIDE THE | | | DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET | | | ACCESSIBLE FROM THE BALCONY, DECK, OR PORCH. THE | | | RECEPTACLE OUTLET SHALL NOT BE LOCATED MORE THAN 2.0 M | | | (61???2 FT) ABOVE THE BALCONY, DECK, OR PORCH WALKING | | | SURFACE. | | | | | | 7) PLEASE RESPOND TO PREVIOUS COMMENT. DETAIL THE | | | REQUIRED SHOW WINDOW RECEPTACLES IN THE RETAIL SPACES. | | | NEC 210.62 | | | | | | NEC 210.62 SHOW WINDOWS. AT LEAST ONE 125-VOLT, | | | SINGLE-PHASE, 15- OR 20-AMPERE-RATED RECEPTACLE OUTLET | | | SHALL BE INSTALLED WITHIN 450 MM (18 IN.) OF THE TOP OF | | | A SHOW WINDOW FOR EACH 3.7 LINEAR M (12 LINEAR FT) OR | | | MAJOR FRACTION THEREOF OF SHOW WINDOW AREA MEASURED | | | HORIZONTALLY AT ITS MAXIMUM WIDTH. | | | | | | 8) PLEASE RESPOND TO PREVIOUS COMMENT, PLEASE INDICATE | | | TYPE FIRE RESISTANCE RATING FOR BUILDING AND THE | | | APPLICABLE WIRING METHODS TO BE USED. NEC 110.8, NEC | | | CHAPTER 3 WIRING METHODS AND MATERIALS AND NEC TABLE | | | ANNEX E | | | | | | NEC 110.8 WIRING METHODS. ONLY WIRING METHODS | | | RECOGNIZED AS SUITABLE ARE INCLUDED IN THIS CODE. THE | | | RECOGNIZED METHODS OF WIRING SHALL BE PERMITTED TO BE | | | INSTALLED IN ANY TYPE OF BUILDING OR OCCUPANCY, EXCEPT | | | AS OTHERWISE PROVIDED IN THIS CODE. | | | | | | 9) PLEASE RESPOND TO PREVIOUS COMMENT. VALUE FOR WORK | | | STATED ON PERMIT APPLICATION APPEARS LOW. PROVIDE A | | | BREAKDOWN OF ALL MATERIALS AND LABOR, OR, AT YOUR | | | DISCRETION, PROVIDE A SIGNED CONTRACTOR PROVIDE A | | | REASONABLE VALUE. WPB F.B.C. 109.3 | | | | | | FBC 109.3 THE APPLICANT FOR A PERMIT SHALL PROVIDE AN | | | ESTIMATED PERMIT VALUE AT TIME OF APPLICATION. PERMIT | | | VALUATIONS SHALL INCLUDE TOTAL VALUE OF WORK, INCLUDING | | | MATERIALS AND LABOR, FOR WHICH THE PERMIT IS BEING | | | ISSUED, SUCH AS ELECTRICAL, GAS, MECHANICAL, PLUMBING | | | EQUIPMENT AND PERMANENT SYSTEMS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE VALUATION IS UNDERESTIMATED | | | ON THE APPLICATION, THE PERMIT SHALL BE DENIED, UNLESS | | | THE APPLICANT CAN SHOW DETAILED ESTIMATES TO MEET THE | | | APPROVAL OF THE BUILDING OFFICIAL. FINAL BUILDING | | | PERMIT VALUATION SHALL BE SET BY THE BUILDING OFFICIAL | | | | | | 10) PLEASE RESPOND TO PREVIOUS COMMENT. PLEASE INDICATE | | | THE REQUIRED SIGN LIGHTING OUTLETS FOR EACH COMMERCIAL | | | SPACE REQUIRED PER NEC 600.5(A) | | | | | | NEC 605(A) REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL | | | BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO | | | PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE OUTLET | | | IN AN ACCESSIBLE LOCATION AT EACH ENTRANCE TO EACH | | | TENANT SPACE FOR SIGN OR OUTLINE LIGHTING SYSTEM USE. | | | THE OUTLET(S) SHALL BE SUPPLIED BY A BRANCH CIRCUIT | | | RATED AT LEAST 20 AMPERES THAT SUPPLIES NO OTHER LOAD. | | | SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE CONSIDERED | | | ACCESSIBLE TO PEDESTRIANS. | | | | | | 11) PLEASE RESPOND TO PREVIOUS COMMENT. PLEASE INDICATE | | | COMPLIANCE WITH THE F.B.C.E.C. C405.2 FOR LIGHTING | | | CONTROLS IN COMMERCIAL SPACES. FBCEC 405.2 LIGHTING | | | CONTROLS MANDATORY | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-12-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-12-19 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-12-19 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2022-12-19 13:29:17 | ELECTRIC REVIEW FAILED | | | 1) VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | | LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR, | | | OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR | | | PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3 | | | 2) PLEASE PROVIDE CLARITY AS TO RISER DIAGRAM | | | INDICATING A HOUSE PANEL IS NOT METERED AND WITHOUT | | | MAIN OVERCURRENT PROTECTION. NEC 215.5 | | | 3) PLEASE PROVIDE CLARITY AS TO SERVICE RISER INDICATES | | | A 400 AMP MAIN, (19) METERS/DISCONNECTS, HOUSE PANEL | | | AND UNDERGROUND SERVICE WHEN PREVIOUS ELECTRICAL | | | SERVICE, PERMITTED PREVIOUSLY ONLY INDICATES A 300 AMP | | | SERVICE WITH (18) METERS AND DISCONNECTS. IF THIS IS | | | NEW WORK PLEASE INDICATE ALL EXISTING ELECTRIC AND NEW | | | PROPOSED ELECTRIC WORK TO BE DONE. FBC 107.2 AND NEC | | | 215.5 | | | 4) PANEL SCHEDULES INDICATE SPLIT SYSTEM AIR | | | CONDITIONING. PLEASE DETAIL THE OUTDOOR CONDENSER UNITS | | | ON ELECTRIC FLOOR PLAN. FBC 107.2 | | | 5) PLEASE INDICATE TYPE FIRE RESISTANCE RATING FOR | | | BUILDING AND THE APPLICABLE WIRING METHODS TO BE USED. | | | FBC 107.2 | | | 6) PLEASE INDICATE VIA NOTE ON PLAN THAT FIRE ALARM AND | | | OTHER LOW VOLTAGE SYSTEMS REQUIRE A SEPARATE PERMIT. | | | 7) PLEASE INDICATE APPLICABLE CIRCUITS TO COMPLY WITH | | | NEC 210.12 ARC FAULT PROTECTION ON PANEL SCHEDULES AND | | | FLOOR PLANS. | | | 8) PLEASE INDICATE COMPLIANCE WITH NEC 210.62 FOR SHOW | | | WINDOW RECEPTACLES IN COMMERCIAL SPACES. | | | 9) PLEASE INDICATE THE REQUIRED SIGN LIGHTING OUTLETS | | | REQUIRED PER NEC 600.5 FOR EACH COMMERCIAL SPACE | | | 10) PLEASE INDICATE COMPLIANCE WITH THE F.B.C.E.C. | | | C405.2 FOR LIGHTING CONTROLS IN COMMERCIAL SPACES | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-06 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2023-07-10 14:54:13 | THERE ARE NO INDICATIONS THAT THE PREVIOUS COMMENTS | | | FROM FIRE WERE SPECIFICALY ADDRESSED AND ARE | | | REUSUBMITTED BELOW: | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF WORK INVOLVING A 2 STORY | | | APARTMENT BUILDING OF 15 LIVING UNITS; HOWEVER, THERE | | | IS NO INDICATIONS OF AN EXISTING OR NEW FIRE ALARM | | | SYSTEMS. | | | | | | PER NFPA 101 CH 31 EXISTING APARTMENT BUILDINGS. | | | | | | 31.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | | 31.3.4.1 GENERAL. | | | 31.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN | | | HEIGHT OR WITH | | | MORE THAN 11 DWELLING UNITS, OTHER THAN THOSE MEETING | | | THE REQUIREMENTS | | | OF 31.3.4.1.2, SHALL BE PROVIDED WITH A FIRE ALARM | | | SYSTEM IN ACCORDANCE | | | WITH SECTION 9.6, EXCEPT AS MODIFIED BY 31.3.4.2 | | | THROUGH 31.3.4.5. | | | | | | PLEASE REVIEW AND PROVIDE PER THE REQUIREMENT. | | | | | | | | | 2) THE 2ND FLOOR MEANS OF EGRESS ARRANGEMENT DOES NOT | | | APPEAR TO MEET THE MINIMUM REQUIREMENT ****40' IS | | | INDICATED IN THE CORRIDOR | | | | | | 31.2.5 ARRANGEMENT OF MEANS OF EGRESS | | | | | | 31.2.5.3.1 NO COMMON PATH OF TRAVEL SHALL EXCEED 35 FT | | | (10.7 M) IN | | | BUILDINGS NOT PROTECTED THROUGHOUT BY AN APPROVED, | | | SUPERVISED AUTOMATIC | | | SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH 31.3.5. | | | TRAVEL WITHIN A | | | DWELLING UNIT SHALL NOT BE INCLUDED WHEN CALCULATING | | | COMMON PATH OF | | | TRAVEL. | | | | | | | | | 3) ADDRESSED | | | | | | | | | | | | 4) THERE ARE INDCATIIONS OF A FIRE ESCAPE STAIR WITH | | | EXPOSURE TO WINDOWS | | | | | | 31.2.2.9 FIRE ESCAPE STAIRS. FIRE ESCAPE STAIRS | | | COMPLYING WITH 7.2.8 | | | SHALL BE PERMITTED | | | | | | 7.2.8.2 PROTECTION OF OPENINGS. FIRE ESCAPE STAIRS | | | SHALL BE EXPOSED | | | TO THE SMALLEST POSSIBLE NUMBER OF WINDOW AND DOOR | | | OPENINGS, AND EACH | | | OPENING SHALL BE PROTECTED WITH APPROVED FIRE DOOR OR | | | FIRE WINDOW ASSEM BLIES WHERE THE OPENING OR ANY | | | PORTION OF THE OPENING IS LOCATED AS | | | FOLLOWS: | | | (1) HORIZONTALLY, WITHIN 15 FT (4570 MM) OF ANY | | | BALCONY, PLATFORM, OR | | | STAIRWAY CONSTITUTING A COMPONENT OF THE FIRE ESCAPE | | | STAIR | | | (2) BELOW, WITHIN THREE STORIES OR 36 FT (11 M) OF ANY | | | BALCONY, PLATFORM, | | | WALKWAY, OR STAIRWAY CONSTITUTING A COMPONENT OF THE | | | FIRE ESCAPE | | | STAIR, OR WITHIN TWO STORIES OR 24 FT (7320 MM) OF A | | | PLATFORM OR | | | WALKWAY LEADING FROM ANY STORY TO THE FIRE ESCAPE STAIR | | | (3) ABOVE, WITHIN 10 FT (3050 MM) OF ANY BALCONY, | | | PLATFORM, OR WALK WAY, AS MEASURED VERTICALLY, OR | | | WITHIN 10 FT (3050 MM) OF ANY STAIR | | | TREAD SURFACE, AS MEASURED VERTICALLY | | | (4) FACING A COURT SERVED BY A FIRE ESCAPE STAIR, WHERE | | | THE LEAST DIMEN SION OF THE COURT DOES NOT EXCEED | | | ONE-THIRD OF THE HEIGHT TO THE | | | UPPERMOST PLATFORM OF THE FIRE ESCAPE STAIR, MEASURED | | | FROM THE | | | FINISHED GROUND LEVEL | | | (5) FACING AN ALCOVE SERVED BY A FIRE ESCAPE STAIR, | | | WHERE THE WIDTH OF | | | THE ALCOVE DOES NOT EXCEED ONE-THIRD, OR THE DEPTH OF | | | THE ALCOVE | | | DOES NOT EXCEED ONE-FOURTH, OF THE HEIGHT TO THE | | | UPPERMOST PLATFORM | | | OF THE FIRE ESCAPE STAIR, MEASURED FROM THE FINISHED | | | GROUND LEVEL | | | | | | PLEASE REVIEW AND PROVIDE DETAILS FOR THE REQUIREMENT. | | | | | | | | | 5) ON THE 1ST FLOOR MIDDLE BUSINESS SPACE THERE APPEARS | | | TO BE A STORAGE UNDER THE EXIT STAIR. | | | | | | 31.2.2.3.1 STAIRS. STAIRS COMPLYING WITH 7.2.2 SHALL BE | | | PERMITTED. | | | | | | 7.2.2.5.3.2 ENCLOSED, USABLE SPACE SHALL BE PERMITTED | | | UNDER STAIRS, PROVIDED THAT BOTH OF THE FOLLOWING | | | CRITERIA ARE MET: | | | (1) THE SPACE SHALL BE SEPARATED FROM THE STAIR | | | ENCLOSURE BY THE SAME | | | FIRE RESISTANCE AS THE EXIT ENCLOSURE. | | | (2) ENTRANCE TO THE ENCLOSED, USABLE SPACE SHALL NOT BE | | | FROM WITHIN THE | | | STAIR ENCLOSURE. (SEE ALSO 7.1.3.2.3) | | | | | | PLEASE REVIEW AND PROVIDE PRETECTION DETAILS. | | | | | | | | | 6) ON THE 1ST FLOOR BUSINESSES, 2 OF THE BUSINESS STOCK | | | ROOMS DO NOT HAVE EXIT SIGNS THAT WILL LEAD PEOPLE TO | | | THAT DOOR TO EXIT INTO THE MAIN ARA. | | | | | | 31.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS | | | SHALL HAVE | | | SIGNS IN ACCORDANCE WITH SECTION 7.10 IN ALL BUILDINGS | | | REQUIRING MORE | | | THAN ONE EXIT | | | | | | 7.10.1.2 EXITS. | | | | | | 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS | | | THAT OBVIOUSLY | | | AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED | | | BY AN APPROVED | | | SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT | | | ACCESS | | | | | | 7.10.1.5 EXIT ACCESS. | | | 7.10.1.5.1 ACCESS TO EXITS SHALL BE MARKED BY APPROVED, | | | READILY VISIBLE | | | SIGNS IN ALL CASES WHERE THE EXIT OR WAY TO REACH THE | | | EXIT IS NOT READILY | | | APPARENT TO THE OCCUPANTS | | | | | | PLEASE REVIEW AND PROVIDE PRETECTION DETAILS. | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-02-24 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2023-02-24 12:41:41 | SEVERAL OF THE PREVIOUS COMMENTS FROM FIRE DO NOT | | | APPEAR TO BE ADDRESSES AND ARE REUSUBMITTED BELOW: | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF WORK INVOLVING A 2 STORY | | | APARTMENT BUILDING OF 15 LIVING UNITS; HOWEVER, THERE | | | IS NO INDICATIONS OF AN EXISTING OR NEW FIRE ALARM | | | SYSTEMS. | | | | | | PER NFPA 101 CH 31 EXISTING APARTMENT BUILDINGS. | | | | | | 31.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | | 31.3.4.1 GENERAL. | | | 31.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN | | | HEIGHT OR WITH | | | MORE THAN 11 DWELLING UNITS, OTHER THAN THOSE MEETING | | | THE REQUIREMENTS | | | OF 31.3.4.1.2, SHALL BE PROVIDED WITH A FIRE ALARM | | | SYSTEM IN ACCORDANCE | | | WITH SECTION 9.6, EXCEPT AS MODIFIED BY 31.3.4.2 | | | THROUGH 31.3.4.5. | | | | | | PLEASE REVIEW AND PROVIDE PER THE REQUIREMENT. | | | | | | | | | 2) THE 2ND FLOOR MEANS OF EGRESS ARRANGEMENT DOES NOT | | | APPEAR TO MEET THE MINIMUM REQUIREMENT ****40' IS | | | INDICATED IN THE CORRIDOR | | | | | | 31.2.5 ARRANGEMENT OF MEANS OF EGRESS | | | | | | 31.2.5.3.1 NO COMMON PATH OF TRAVEL SHALL EXCEED 35 FT | | | (10.7 M) IN | | | BUILDINGS NOT PROTECTED THROUGHOUT BY AN APPROVED, | | | SUPERVISED AUTOMATIC | | | SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH 31.3.5. | | | TRAVEL WITHIN A | | | DWELLING UNIT SHALL NOT BE INCLUDED WHEN CALCULATING | | | COMMON PATH OF | | | TRAVEL. | | | | | | | | | 3) ADDRESSED | | | | | | | | | | | | 4) THERE ARE INDCATIIONS OF A FIRE ESCAPE STAIR WITH | | | EXPOSURE TO WINDOWS | | | | | | 31.2.2.9 FIRE ESCAPE STAIRS. FIRE ESCAPE STAIRS | | | COMPLYING WITH 7.2.8 | | | SHALL BE PERMITTED | | | | | | 7.2.8.2 PROTECTION OF OPENINGS. FIRE ESCAPE STAIRS | | | SHALL BE EXPOSED | | | TO THE SMALLEST POSSIBLE NUMBER OF WINDOW AND DOOR | | | OPENINGS, AND EACH | | | OPENING SHALL BE PROTECTED WITH APPROVED FIRE DOOR OR | | | FIRE WINDOW ASSEM BLIES WHERE THE OPENING OR ANY | | | PORTION OF THE OPENING IS LOCATED AS | | | FOLLOWS: | | | (1) HORIZONTALLY, WITHIN 15 FT (4570 MM) OF ANY | | | BALCONY, PLATFORM, OR | | | STAIRWAY CONSTITUTING A COMPONENT OF THE FIRE ESCAPE | | | STAIR | | | (2) BELOW, WITHIN THREE STORIES OR 36 FT (11 M) OF ANY | | | BALCONY, PLATFORM, | | | WALKWAY, OR STAIRWAY CONSTITUTING A COMPONENT OF THE | | | FIRE ESCAPE | | | STAIR, OR WITHIN TWO STORIES OR 24 FT (7320 MM) OF A | | | PLATFORM OR | | | WALKWAY LEADING FROM ANY STORY TO THE FIRE ESCAPE STAIR | | | (3) ABOVE, WITHIN 10 FT (3050 MM) OF ANY BALCONY, | | | PLATFORM, OR WALK WAY, AS MEASURED VERTICALLY, OR | | | WITHIN 10 FT (3050 MM) OF ANY STAIR | | | TREAD SURFACE, AS MEASURED VERTICALLY | | | (4) FACING A COURT SERVED BY A FIRE ESCAPE STAIR, WHERE | | | THE LEAST DIMEN SION OF THE COURT DOES NOT EXCEED | | | ONE-THIRD OF THE HEIGHT TO THE | | | UPPERMOST PLATFORM OF THE FIRE ESCAPE STAIR, MEASURED | | | FROM THE | | | FINISHED GROUND LEVEL | | | (5) FACING AN ALCOVE SERVED BY A FIRE ESCAPE STAIR, | | | WHERE THE WIDTH OF | | | THE ALCOVE DOES NOT EXCEED ONE-THIRD, OR THE DEPTH OF | | | THE ALCOVE | | | DOES NOT EXCEED ONE-FOURTH, OF THE HEIGHT TO THE | | | UPPERMOST PLATFORM | | | OF THE FIRE ESCAPE STAIR, MEASURED FROM THE FINISHED | | | GROUND LEVEL | | | | | | PLEASE REVIEW AND PROVIDE DETAILS FOR THE REQUIREMENT. | | | | | | | | | 5) ON THE 1ST FLOOR MIDDLE BUSINESS SPACE THERE APPEARS | | | TO BE A STORAGE UNDER THE EXIT STAIR. | | | | | | 31.2.2.3.1 STAIRS. STAIRS COMPLYING WITH 7.2.2 SHALL BE | | | PERMITTED. | | | | | | 7.2.2.5.3.2 ENCLOSED, USABLE SPACE SHALL BE PERMITTED | | | UNDER STAIRS, PROVIDED THAT BOTH OF THE FOLLOWING | | | CRITERIA ARE MET: | | | (1) THE SPACE SHALL BE SEPARATED FROM THE STAIR | | | ENCLOSURE BY THE SAME | | | FIRE RESISTANCE AS THE EXIT ENCLOSURE. | | | (2) ENTRANCE TO THE ENCLOSED, USABLE SPACE SHALL NOT BE | | | FROM WITHIN THE | | | STAIR ENCLOSURE. (SEE ALSO 7.1.3.2.3) | | | | | | PLEASE REVIEW AND PROVIDE PRETECTION DETAILS. | | | | | | | | | 6) ON THE 1ST FLOOR BUSINESSES, 2 OF THE BUSINESS STOCK | | | ROOMS DO NOT HAVE EXIT SIGNS THAT WILL LEAD PEOPLE TO | | | THAT DOOR TO EXIT INTO THE MAIN ARA. | | | | | | 31.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS | | | SHALL HAVE | | | SIGNS IN ACCORDANCE WITH SECTION 7.10 IN ALL BUILDINGS | | | REQUIRING MORE | | | THAN ONE EXIT | | | | | | 7.10.1.2 EXITS. | | | | | | 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS | | | THAT OBVIOUSLY | | | AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED | | | BY AN APPROVED | | | SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT | | | ACCESS | | | | | | 7.10.1.5 EXIT ACCESS. | | | 7.10.1.5.1 ACCESS TO EXITS SHALL BE MARKED BY APPROVED, | | | READILY VISIBLE | | | SIGNS IN ALL CASES WHERE THE EXIT OR WAY TO REACH THE | | | EXIT IS NOT READILY | | | APPARENT TO THE OCCUPANTS | | | | | | PLEASE REVIEW AND PROVIDE PRETECTION DETAILS. | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-11-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-11-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-11-21 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2022-11-21 13:08:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF WORK INVOLVING A 2 STORY | | | APARTMENT BUILDING OF 15 LIVING UNITS; HOWEVER, THERE | | | IS NO INDICATIONS OF AN EXISTING OR NEW FIRE ALARM | | | SYSTEMS. | | | | | | PER NFPA 101 CH 31 EXISTING APARTMENT BUILDINGS. | | | | | | 31.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS. | | | 31.3.4.1 GENERAL. | | | 31.3.4.1.1 APARTMENT BUILDINGS FOUR OR MORE STORIES IN | | | HEIGHT OR WITH | | | MORE THAN 11 DWELLING UNITS, OTHER THAN THOSE MEETING | | | THE REQUIREMENTS | | | OF 31.3.4.1.2, SHALL BE PROVIDED WITH A FIRE ALARM | | | SYSTEM IN ACCORDANCE | | | WITH SECTION 9.6, EXCEPT AS MODIFIED BY 31.3.4.2 | | | THROUGH 31.3.4.5. | | | | | | PLEASE REVIEW AND PROVIDE PER THE REQUIREMENT. | | | | | | | | | 2) THE 2ND FLOOR MEANS OF EGRESS ARRANGEMENT DOES NOT | | | APPEAR TO MEET THE MINIMUM REQUIREMENT | | | | | | 31.2.5 ARRANGEMENT OF MEANS OF EGRESS | | | | | | 31.2.5.3.1 NO COMMON PATH OF TRAVEL SHALL EXCEED 35 FT | | | (10.7 M) IN | | | BUILDINGS NOT PROTECTED THROUGHOUT BY AN APPROVED, | | | SUPERVISED AUTOMATIC | | | SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH 31.3.5. | | | TRAVEL WITHIN A | | | DWELLING UNIT SHALL NOT BE INCLUDED WHEN CALCULATING | | | COMMON PATH OF | | | TRAVEL. | | | | | | | | | 3) THE 2ND FLOOR EXIT EXTERIOR STAIR APPEAR TO LAND | | | INTO AN FENCE ENCLOSED AREA WITH RESTRICTED EXITING | | | CAPACITY AND A GATE. | | | | | | THERE IS NO INDICATION OF EXIT HARDWARE OR | | | LOCKS/LATCHING THAT MEET THE MINIMUM REQUIRMENT FOR AN | | | EXIT. | | | | | | 31.2.2.2 DOORS | | | | | | 31.2.2.2.2 DOOR-LOCKING ARRANGEMENTS SHALL COMPLY WITH | | | 30.2.2.2.2.1, | | | 30.2.2.2.2.2, 30.2.2.2.2.3, OR 31.2.2.2.2.4. | | | 31.2.2.2.2.1 NO DOOR IN ANY MEANS OF EGRESS SHALL BE | | | LOCKED AGAINST | | | EGRESS WHEN THE BUILDING IS OCCUPIED | | | | | | | | | | | | 4) THERE ARE INDCATIIONS OF A FIRE ESCAPE STAIR WITH | | | EXPOSURE TO TO WINDOWS | | | | | | 31.2.2.9 FIRE ESCAPE STAIRS. FIRE ESCAPE STAIRS | | | COMPLYING WITH 7.2.8 | | | SHALL BE PERMITTED | | | | | | 7.2.8.2 PROTECTION OF OPENINGS. FIRE ESCAPE STAIRS | | | SHALL BE EXPOSED | | | TO THE SMALLEST POSSIBLE NUMBER OF WINDOW AND DOOR | | | OPENINGS, AND EACH | | | OPENING SHALL BE PROTECTED WITH APPROVED FIRE DOOR OR | | | FIRE WINDOW ASSEM BLIES WHERE THE OPENING OR ANY | | | PORTION OF THE OPENING IS LOCATED AS | | | FOLLOWS: | | | (1) HORIZONTALLY, WITHIN 15 FT (4570 MM) OF ANY | | | BALCONY, PLATFORM, OR | | | STAIRWAY CONSTITUTING A COMPONENT OF THE FIRE ESCAPE | | | STAIR | | | (2) BELOW, WITHIN THREE STORIES OR 36 FT (11 M) OF ANY | | | BALCONY, PLATFORM, | | | WALKWAY, OR STAIRWAY CONSTITUTING A COMPONENT OF THE | | | FIRE ESCAPE | | | STAIR, OR WITHIN TWO STORIES OR 24 FT (7320 MM) OF A | | | PLATFORM OR | | | WALKWAY LEADING FROM ANY STORY TO THE FIRE ESCAPE STAIR | | | (3) ABOVE, WITHIN 10 FT (3050 MM) OF ANY BALCONY, | | | PLATFORM, OR WALK WAY, AS MEASURED VERTICALLY, OR | | | WITHIN 10 FT (3050 MM) OF ANY STAIR | | | TREAD SURFACE, AS MEASURED VERTICALLY | | | (4) FACING A COURT SERVED BY A FIRE ESCAPE STAIR, WHERE | | | THE LEAST DIMEN SION OF THE COURT DOES NOT EXCEED | | | ONE-THIRD OF THE HEIGHT TO THE | | | UPPERMOST PLATFORM OF THE FIRE ESCAPE STAIR, MEASURED | | | FROM THE | | | FINISHED GROUND LEVEL | | | (5) FACING AN ALCOVE SERVED BY A FIRE ESCAPE STAIR, | | | WHERE THE WIDTH OF | | | THE ALCOVE DOES NOT EXCEED ONE-THIRD, OR THE DEPTH OF | | | THE ALCOVE | | | DOES NOT EXCEED ONE-FOURTH, OF THE HEIGHT TO THE | | | UPPERMOST PLATFORM | | | OF THE FIRE ESCAPE STAIR, MEASURED FROM THE FINISHED | | | GROUND LEVEL | | | | | | PLEASE REVIEW AND PROVIDE DETAILS FOR THE REQUIREMENT. | | | | | | | | | 5) ON THE 1ST FLOOR MIDDLE BUSINESS SPACE THERE APPEARS | | | TO BE A STORAGE UNDER THE EXIT STAIR. | | | | | | 31.2.2.3.1 STAIRS. STAIRS COMPLYING WITH 7.2.2 SHALL BE | | | PERMITTED. | | | | | | 7.2.2.5.3.2 ENCLOSED, USABLE SPACE SHALL BE PERMITTED | | | UNDER STAIRS, PROVIDED THAT BOTH OF THE FOLLOWING | | | CRITERIA ARE MET: | | | (1) THE SPACE SHALL BE SEPARATED FROM THE STAIR | | | ENCLOSURE BY THE SAME | | | FIRE RESISTANCE AS THE EXIT ENCLOSURE. | | | (2) ENTRANCE TO THE ENCLOSED, USABLE SPACE SHALL NOT BE | | | FROM WITHIN THE | | | STAIR ENCLOSURE. (SEE ALSO 7.1.3.2.3) | | | | | | PLEASE REVIEW AND PROVIDE PRETECTION DETAILS. | | | | | | | | | 6) ON THE 1ST FLOOR BUSINESSES, 2 OF THE BUSINESS STOCK | | | ROOMS DO NOT HAVE EXIT SIGNS THAT WILL LEAD PEOPLE TO | | | THAT DOOR TO EXIT INTO THE MAIN ARA. | | | | | | 31.2.10 MARKING OF MEANS OF EGRESS. MEANS OF EGRESS | | | SHALL HAVE | | | SIGNS IN ACCORDANCE WITH SECTION 7.10 IN ALL BUILDINGS | | | REQUIRING MORE | | | THAN ONE EXIT | | | | | | 7.10.1.2 EXITS. | | | | | | 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS | | | THAT OBVIOUSLY | | | AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED | | | BY AN APPROVED | | | SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT | | | ACCESS | | | | | | 7.10.1.5 EXIT ACCESS. | | | 7.10.1.5.1 ACCESS TO EXITS SHALL BE MARKED BY APPROVED, | | | READILY VISIBLE | | | SIGNS IN ALL CASES WHERE THE EXIT OR WAY TO REACH THE | | | EXIT IS NOT READILY | | | APPARENT TO THE OCCUPANTS | | | | | | PLEASE REVIEW AND PROVIDE PRETECTION DETAILS. | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-30 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-30 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-03-10 |
Time |
05:59 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-03-10 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2023-03-10 05:59:20 | 2ND GAS REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.3.5.1.5 GAS PLANS NOT SHOWN. | | | PLEASE SHOW GAS MODIFICTIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-08 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-12-08 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2022-12-08 09:14:54 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.3.5.1.5 GAS PLANS NOT SHOWN. | | | PLEASE SHOW GAS MODIFICTIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-25 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-06-29 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-10 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-23 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-01-04 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-11-18 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-12-21 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-12-14 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-07-21 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-07-21 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-27 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-27 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2023-02-27 17:14:23 | 2ND ATTEMPT: | | | | | | SHEET A-1 INDICATES MECHANICAL SHEETS M-1, M-2 AND M-3, | | | THESE SHEETS WERE NOT SUBMITTED IN THIS SUBMITTAL. | | | PLEASE SUBMIT A COMPLETE MECHANICAL DESIGN FOR THE | | | SCOPE OF WORK BEING COMPLETED UNDER THIS PERMIT, | | | INCLUDING MECHANICAL EQUIPMENT SIZING CALCULATIONS. FBC | | | 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-12-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-12-16 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-12-16 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2022-12-16 08:28:39 | SHEET A-1 INDICATES MECHANICAL SHEETS M-1, M-2 AND M-3, | | | THESE SHEETS WERE NOT SUBMITTED IN THIS SUBMITTAL. | | | PLEASE SUBMIT A COMPLETE MECHANICAL DESIGN FOR THE | | | SCOPE OF WORK BEING COMPLETED UNDER THIS PERMIT, | | | INCLUDING MECHANICAL EQUIPMENT SIZING CALCULATIONS. FBC | | | 107.3.5 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-30 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-30 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2023-06-30 12:31:34 | 3RD PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 912.1 - THERE IS ONE BATHROOM GROUP AT THE | | | TOP OF THE PAGE AND ONE ON THE BOTTOM LEFT OF THE PAGE | | | THAT IS NOT VENTED TO CODE. THE SHOWER AND WATER CLOSET | | | ARE BOTH ON THE HIGH SIDE OF THE VENTED FIXTURE | | | CONNECTION AND ARE NOT ALLOWED TO BE. ONLY ONE WET | | | VENTED FIXTURE IS ALLOWED ON THE HIGH SIDE OF THE | | | VENTED FIXTURE CONNECTION. EITHER CHANGE THE VENTING | | | METHOD FROM WET VENT TO ANOTHER METHOD OR RECONFIGURE | | | THE CONNECTIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-02-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-02-24 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-02-24 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2023-02-24 07:44:15 | 2ND PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | PREVIOUS COMMENTS NOT ADDRESSED AND CHANGES NOT MADE | | | | | | 1. 2020 FPC 912.1 - THERE IS ONE BATHROOM GROUP AT THE | | | TOP OF THE PAGE AND ONE ON THE BOTTOM LEFT OF THE PAGE | | | THAT IS NOT VENTED TO CODE. THE SHOWER AND WATER CLOSET | | | ARE BOTH ON THE HIGH SIDE OF THE VENTED FIXTURE | | | CONNECTION AND ARE NOT ALLOWED TO BE. ONLY ONE WET | | | VENTED FIXTURE IS ALLOWED ON THE HIGH SIDE OF THE | | | VENTED FIXTURE CONNECTION. EITHER CHANGE THE VENTING | | | METHOD FROM WET VENT TO ANOTHER METHOD OR RECONFIGURE | | | THE CONNECTIONS. THERE ARE SEVERAL BRANCHES THAT ARE | | | NON-COMPLIANT. "SINKS" CANNOT WET VENT BATHROOM GROUP | | | FIXTURES, ONLY "OTHER BATHROOM GROUP FIXTURES" CAN LIKE | | | LAVATORIES. | | | | | | PLEASE RECONFIGURE THE ISORMETRIC DRAWING TO ADDRESS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-12-08 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-12-08 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2022-12-08 09:13:15 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 912.1 - THERE IS ONE BATHROOM GROUP AT THE | | | TOP OF THE PAGE AND ONE ON THE BOTTOM LEFT OF THE PAGE | | | THAT IS NOT VENTED TO CODE. THE SHOWER AND WATER CLOSET | | | ARE BOTH ON THE HIGH SIDE OF THE VENTED FIXTURE | | | CONNECTION AND ARE NOT ALLOWED TO BE. ONLY ONE WET | | | VENTED FIXTURE IS ALLOWED ON THE HIGH SIDE OF THE | | | VENTED FIXTURE CONNECTION. EITHER CHANGE THE VENTING | | | METHOD FROM WET VENT TO ANOTHER METHOD OR RECONFIGURE | | | THE CONNECTIONS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-25 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-25 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-10 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-10 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-12-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-12-21 |
Time |
08:25 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2022-12-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-21 08:25:12 | ARCHITECT OR INTERIOR DECORATOR, DIGITAL SIGNING & | | | SEALING PLANS. 61G1-16.005 PROCEDURES FOR DIGITALLY | | | SIGNING AND SEALING AND FOR ELECTRONICALLY TRANSMITTING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2023-07-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2023-07-19 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-07-19 14:56:50 | ** INTERIOR MODIFICATIONS ONLY. ANY EXTERIOR WORK WILL | | | REQUIRE SEPARATE PERMITS. ** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2023-03-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2023-03-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-03 11:51:24 | ** INTERIOR MODIFICATIONS ONLY. ANY EXTERIOR WORK WILL | | | REQUIRE SEPARATE PERMITS. ** | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-04 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2023-01-04 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2023-01-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-04 09:37:58 | REMODEL OF EXISTING INTERIOR SPACE ONLY. DOES NOT | | | TRIGGER 50% THRESHOLD FOR LANDSCAPE IMPROVEMENTS. |
|
|
|