| Plan Review Stops For Permit 22040936 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-11-08 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-06-29 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-29 10:59:04 | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-05-09 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-05-09 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2022-05-09 17:13:28 | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-11-08 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-11-08 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-06-29 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-29 10:57:46 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22040936 | | | ADD: 701 S OLIVE AVE # 1903 | | | CONT: STONESTYLES | | | TEL: 561-809-5115 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. JUNE 29TH/2022 | | | ACTION: DENIED | | | | | | 1)2ND REQUEST. THE 3 SUBMITTED FLOOR PLANS DRAWN BY | | | LYNN AUSTIN WILL HAVE TO HAVE EITHER A ARCHITECT OR | | | ENGINEER CREATE THEIR OWN PLANS. PROJECTS GREATER THAN | | | $25,000.00 ARE REQUIRED TO BE SIGNED AND SEALED. | | | 481.229 EXCEPTIONS; EXEMPTIONS FROM LICENSURE (1) (C) | | | ANY OTHER TYPE OF BUILDING COSTING LESS THAN | | | $25,000.00, EXCEPT A SCHOOL, AUDITORIUM, OR OTHER | | | BUILDING INTENDED FOR PUBLIC USE, PROVIDED THAT THE | | | SERVICES OF A REGISTERED ARCHITECT SHALL NOT BE | | | REQUIRED FOR MINOR SCHOOL PROJECTS PURSUANT TO 1013.45. | | | | | | 2) 2ND REQUEST. IT APPEARS THE PROPOSED FLOOR PLAN AND | | | FLOOR PLAN 001 DO NOT MATCH UP, DISCREPANCY IN PLANS. | | | SHEET 001 FLOOR PLAN THE MAIN DOUBLE DOOR ENTRY. THE | | | CORRIDOR OUTSIDE THE UNIT TURNS 90 DEGREES BUT THE | | | FRONT ENTRY DOORS ARE AT A 45 DEGREE ANGLE TO THE | | | CORRIDOR, SHEET 003 THE PROPOSED FLOOR PLAN HAS THE | | | FRONT ENTRY DOOR PARALLEL TO THE CORRIDOR DISCREPANCY | | | IN PLANS. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | SHOW AS A FULL FLOOR PLAN WITH CORRIDOR. | | | | | | 3)2ND REQUEST. AS VIEWED FROM PROPOSED FLOOR PLAN THE | | | KITCHEN AND BATHROOMS HAVE BEEN REVERED THAT WILL | | | CREATE NEW PLUMBING PENETRATIONS OF THE POST TENSIONED | | | FLOOR SYSTEM. POST TENSION SLAB/ NEW HOLES. THE PLAN IS | | | SILENT AS IF THE LOCATION OF THE EXISTING TUB DRAIN IS | | | GOING TO BE REUSED IN THE SAME LOCATION. IF NOT, THEN | | | THE FLOOR SLAB WILL NEED TO BE X-RAYED TO FIND THE POST | | | TENSION CHORD LOCATIONS. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 4) 2ND REQUEST. -PENETRATIONS FIRESTOP SYSTEMS | | | (HORIZONTAL ASSEMBLIES). IF A NEW FLOOR PENETRATION IS | | | MADE FOR THE FUTURE SHOWER DRAIN, THEN YOU NEED TO SHOW | | | COMPLIANCE WITH THE 2020 FBC-B SECTION 714.5.1.2. | | | THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL | | | ASSEMBLIES). THROUGH PENETRATIONS SHALL BE PROTECTED BY | | | A THROUGH PENETRATION FIRESTOP SYSTEM INSTALLED IN | | | ACCORDANCE WITH ASTM E814 OR UL 1479. THE SYSTEM SHALL | | | HAVE AN F RATING / T RATING OF NOT LESS THAN 1 HOUR BUT | | | NOT LESS THAN THE REQUIRED RATING OF THE FLOOR | | | PENETRATED. | | | | | | 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-05-09 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-05-09 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2022-05-09 17:12:34 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 22040936 | | | ADD: 701 S OLIVE AVE # 1903 | | | CONT: STONESTYLES | | | TEL: 561-809-5115 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MONDAY MAY 09TH/2022 | | | ACTION: DENIED | | | | | | 1) THE 3 SUBMITTED FLOOR PLANS DRAWN BY LYNN AUSTIN | | | WILL HAVE TO HAVE EITHER A ARCHITECT OR ENGINEER CREATE | | | THEIR OWN PLANS. PROJECTS GREATER THAN $25,000.00 ARE | | | REQUIRED TO BE SINGED AND SEALED. 481.229 EXCEPTIONS; | | | EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF | | | BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL, | | | AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE, | | | PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT | | | SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS | | | PURSUANT TO 1013.45. | | | | | | 2) IT APPEARS THE PROPOSED FLOOR PLAN AND FLOOR PLAN | | | 001 DO NOT MATCH UP, DISCREPANCY IN PLANS. SHEET 001 | | | FLOOR PLAN THE MAIN DOUBLE DOOR ENTRY. THE CORRIDOR | | | OUTSIDE THE UNIT TURNS 90 DEGREES BUT THE FRONT ENTRY | | | DOORS ARE AT A 45 DEGREE ANGLE TO THE CORRIDOR, SHEET | | | 003 THE PROPOSED FLOOR PLAN HAS THE FRONT ENTRY DOOR | | | PARALLEL TO THE CORRIDOR DISCREPANCY IN PLANS. | | | 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 3) AS VIEWED FROM PROPOSED FLOOR PLAN THE KITCHEN AND | | | BATHROOMS HAVE BEEN REVERED THAT WILL CREATE NEW | | | PLUMBING PENETRATIONS OF THE POST TENSIONED FLOOR | | | SYSTEM. POST TENSION SLAB/ NEW HOLES. THE PLAN IS | | | SILENT AS IF THE LOCATION OF THE EXISTING TUB DRAIN IS | | | GOING TO BE REUSED IN THE SAME LOCATION. IF NOT, THEN | | | THE FLOOR SLAB WILL NEED TO BE X-RAYED TO FIND THE POST | | | TENSION CHORD LOCATIONS. 107.2.1.2. ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 4) THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL | | | ASSEMBLIES). IF A NEW FLOOR PENETRATION IS MADE FOR THE | | | FUTURE SHOWER DRAIN, THEN YOU NEED TO SHOW COMPLIANCE | | | WITH THE 2020 FBC-B SECTION 714.5.1.2. | | | THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL | | | ASSEMBLIES). THROUGH PENETRATIONS SHALL BE PROTECTED BY | | | A THROUGH PENETRATION FIRESTOP SYSTEM INSTALLED IN | | | ACCORDANCE WITH ASTM E814 OR UL 1479. THE SYSTEM SHALL | | | HAVE AN F RATING / T RATING OF NOT LESS THAN 1 HOUR BUT | | | NOT LESS THAN THE REQUIRED RATING OF THE FLOOR | | | PENETRATED. | | | | | | 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-28 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-30 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-30 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-05-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-19 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-19 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-06-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-06-23 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2022-06-23 11:01:21 | FIRE PROVISO: | | | | | | THERE ARE INDICATIONS OF WALLS BEING REMOVED THAT MAY | | | AFFECT THE REQUIRED FIRE SPRINKLER HEAD COVERAGE. | | | | | | A FIRE SPRINKLER CONTRACTOR IS REQUIRED TO REVIEW THE | | | PROPOSED WORK TO ENSURE CODE COMPLIANT COVERAGE IS | | | MAINTAINED. | | | | | | SHOULD NO WORK BE REQUIRED, A LETTER FROM THAT | | | CONTRACTOR WILL BE REQUIRED TO BE SUBMITTED ON FINAL | | | FIRE INSPECTIONS TO THE FIRE INSPECTOR. | | | | | | SHOULD MODIFICATION BE REQUIRED IT SHALL BE UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND | | | EQUIPMENT. | | | DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM | | | DEVICES/EQUIPMENT. | | | THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT | | | DEMO AND CONSTRUCTION. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-04-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-04-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-04-21 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2022-04-21 13:32:12 | FIRE PROVISO: | | | | | | THERE ARE INDICATIONS OF WALLS BEING REMOVED THAT MAY | | | AFFECT THE REQUIRED FIRE SPRINKLER HEAD COVERAGE. | | | | | | A FIRE SPRINKLER CONTRACTOR IS REQUIRED TO REVIEW THE | | | PROPOSED WORK TO ENSURE CODE COMPLIANT COVERAGE IS | | | MAINTAINED. | | | | | | SHOULD NO WORK BE REQUIRED, A LETTER FROM THAT | | | CONTRACTOR WILL BE REQUIRED TO BE SUBMITTED ON FINAL | | | FIRE INSPECTIONS TO THE FIRE INSPECTOR. | | | | | | SHOULD MODIFICATION BE REQUIRED IT SHALL BE UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND | | | EQUIPMENT. | | | DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM | | | DEVICES/EQUIPMENT. | | | THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT | | | DEMO AND CONSTRUCTION. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-11-28 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-28 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-03 |
Time |
06:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-30 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-22 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-19 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-21 |
Time |
05:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-05-09 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2022-05-09 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-05-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-05 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-05 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2022-05-05 17:10:41 | NO MECHANICAL WORK SHOWN FOR THIS PROJECT. ME |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-11-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-11-04 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-11-04 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-06-24 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-06-24 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2022-06-24 16:31:44 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 22040936 | | | 6/24//22 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES. | | | | | | 1) FAILED. PLUMBING PLANS SHALL BE DRAWN BY THE | | | PLUMBING CONTRACTOR OF RECORD OR A FL. LICENSED | | | ENGINEER- FLORIDA STATUTES 471.003(2) (H) & 471.015. | | | CONTRACTOR PLANS SHALL BEAR THE PRINTED NAME, LICENSE | | | NUMBER, AND SIGNATURE OF THE PLUMBING CONTRACTOR OF | | | RECORD- SEC. 107.2.1 WPB. PLUMBING PLAN P2 NOT SIGNED. | | | | | | 2) FAILED. THE PLUMBING PLANS SHALL INCLUDE A SCOPE OF | | | WORK OUTLINE ITEMIZING ALL REPLACED FIXTURES AND | | | LOCATIONS OF NEW, REPLACED, RELOCATED PLUMBING PIPING. | | | PLUMBING RISER DRAWINGS ARE REQUIRED FOR ALL NEW WATER | | | SUPPLY AND SANITARY DRAINAGE AND VENT PIPING | | | INSTALLATIONS- SEC. 107.2.1 AND 107.3.5.3.13 WPB. NOT | | | PROVIDED. | | | | | | 3) FAILED. NO DETAILS PROVIDED FOR THE GUEST BATH | | | REMODEL. FAIR HOUSING COMPLIANCE: | | | WPB BUILDING DEPT. RECORDS INDICATE THE RESIDENTIAL | | | UNITS AT TWO CITY PLAZA- 701 S OLIVE WERE DESIGNED AND | | | CONSTRUCTED IN ACCORDANCE WITH THE FAIR HOUSING DESIGN | | | ACT. THE PROPOSED KITCHEN AND BATH ALTERATIONS SHALL BE | | | DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE FHDA | | | MANUAL OR THE FAIR HOUSING DESIGN GUIDELINES CONTAINED | | | IN THE FBC ACC. THE DESIGNER SHALL INDICATE COMPLIANCE | | | WITH SPECIFICATION TYPE A OR B AND THE DRAWINGS SHALL | | | REFLECT THE SPECIFICATION. PLEASE REFER TO PAGES 7.34- | | | 7.39 OF THE FHDA MANUAL FOR EXPLANATORY INFORMATION. | | | KITCHEN- REFER TO PAGE 7.5 OF THE FAIR HOUSING ACT | | | DESIGN MANUAL AND REQUIREMENT 7 (1)(A) OF THE | | | GUIDELINES AND SHOW THE REQUIRED 30X48 INCH CLEAR FLOOR | | | SPACE DIAGRAM AND DIMENSIONS FOR A PARALLEL WHEELCHAIR | | | APPROACH AT THE SINK, AND 30X48 INCH CLEAR FLOOR SPACE | | | DIAGRAM AND DIMENSION FOR THE PARALLEL OR FORWARD | | | APPROACH TO THE DISHWASHER. PLEASE NOTE THAT THE | | | REQUIRED CLEAR FLOOR SPACES FOR PARALLEL APPROACHES | | | SHALL BE CENTERED ON THE SINK AND DISHWASHER. | | | PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND | | | APPLIANCES | | | PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND | | | ALL OPPOSING ELEMENTS. | | | PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET | | | DOORS INCLUDING KNEE SPACES. | | | BATH- | | | PAGES 7.56- 7.59 INTERIOR FINISH DIMENSIONS OF THE | | | SHOWER- WIDTH AND DEPTH. | | | PAGES 7.56- 7.59 REQUIRED 30X48-INCH CLEAR FLOOR SPACE | | | PARALLEL APPROACH DIAGRAM FLUSH WITH THE CONTROL SIDE | | | WALL. | | | PAGES 7.56- 7.59 ELEVATION DETAIL SHOWING THE SHOWER | | | CONTROLS LOCATION, AND THE GRAB BAR AND SEAT | | | REINFORCEMENT DETAILS- PAGES- 6.12-6.13. SHOW THE | | | LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF | | | REINFORCEMENT MATERIAL TO BE USED. SEE SEC 603.1 FBC B | | | FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS. | | | | | | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE | | | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND | | | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE | | | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE | | | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET | | | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY | | | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO | | | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF | | | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, | | | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A | | | COPY OF THE FAIR HOUSING AFFIDAVIT. | | | | | | 4) FAILED A, B, & C. A-2: PROVIDE A SHOWER PAN DETAIL- | | | SEC. 417.5.1- 417.5.2.6 FBC P. | | | | | | A) REFER TO SEC. 1002.1: THE HORIZONTAL DISTANCE FROM | | | THE CENTERLINE OF THE NEW BATHTUB DRAIN OUTLET TO THE | | | CENTERLINE OF THE INLET OF THE EXISTING TRAPS SHALL NOT | | | EXCEED 30". PLEASE PLACE A NOTE ON THE PLAN INDICATING | | | COMPLIANCE. | | | | | | B) RELOCATING THE SHOWER DRAIN OUTLETS WILL REQUIRE THE | | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | | SEC. 107.2.1 WPB. | | | | | | C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB | | | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE | | | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED | | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SEC. 315.1 | | | FBC P AND SEC. 714.4.1.2 FBC B. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-03 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-03 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2022-05-03 15:34:23 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22040936 | | | 5/3/22 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLUMBING PLANS SHALL BE DRAWN BY THE PLUMBING | | | CONTRACTOR OF RECORD OR A FL. LICENSED ENGINEER- | | | FLORIDA STATUTES 471.003(2) (H) & 471.015. CONTRACTOR | | | PLANS SHALL BEAR THE PRINTED NAME, LICENSE NUMBER, AND | | | SIGNATURE OF THE PLUMBING CONTRACTOR OF RECORD- SEC. | | | 107.2.1 WPB. | | | | | | 2) THE PLUMBING PLANS SHALL INCLUDE A SCOPE OF WORK | | | OUTLINE ITEMIZING ALL REPLACED FIXTURES AND LOCATIONS | | | OF NEW, REPLACED, RELOCATED PLUMBING PIPING. PLUMBING | | | RISER DRAWINGS ARE REQUIRED FOR ALL NEW WATER SUPPLY | | | AND SANITARY DRAINAGE AND VENT PIPING INSTALLATIONS- | | | SEC. 107.2.1 AND 107.3.5.3.13 WPB. | | | | | | 3) FAIR HOUSING COMPLIANCE: | | | WPB BUILDING DEPT. RECORDS INDICATE THE RESIDENTIAL | | | UNITS AT TWO CITY PLAZA- 701 S OLIVE WERE DESIGNED AND | | | CONSTRUCTED IN ACCORDANCE WITH THE FAIR HOUSING DESIGN | | | ACT. THE PROPOSED KITCHEN AND BATH ALTERATIONS SHALL BE | | | DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE FHDA | | | MANUAL OR THE FAIR HOUSING DESIGN GUIDELINES CONTAINED | | | IN THE FBC ACC. THE DESIGNER SHALL INDICATE COMPLIANCE | | | WITH SPECIFICATION TYPE A OR B AND THE DRAWINGS SHALL | | | REFLECT THE SPECIFICATION. PLEASE REFER TO PAGES 7.34- | | | 7.39 OF THE FHDA MANUAL FOR EXPLANATORY INFORMATION. | | | KITCHEN- REFER TO PAGE 7.5 OF THE FAIR HOUSING ACT | | | DESIGN MANUAL AND REQUIREMENT 7 (1)(A) OF THE | | | GUIDELINES AND SHOW THE REQUIRED 30X48 INCH CLEAR FLOOR | | | SPACE DIAGRAM AND DIMENSIONS FOR A PARALLEL WHEELCHAIR | | | APPROACH AT THE SINK, AND 30X48 INCH CLEAR FLOOR SPACE | | | DIAGRAM AND DIMENSION FOR THE PARALLEL OR FORWARD | | | APPROACH TO THE DISHWASHER. PLEASE NOTE THAT THE | | | REQUIRED CLEAR FLOOR SPACES FOR PARALLEL APPROACHES | | | SHALL BE CENTERED ON THE SINK AND DISHWASHER. | | | PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND | | | APPLIANCES | | | PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND | | | ALL OPPOSING ELEMENTS. | | | PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET | | | DOORS INCLUDING KNEE SPACES. | | | BATH- | | | PAGES 7.56- 7.59 INTERIOR FINISH DIMENSIONS OF THE | | | SHOWER- WIDTH AND DEPTH. | | | PAGES 7.56- 7.59 REQUIRED 30X48-INCH CLEAR FLOOR SPACE | | | PARALLEL APPROACH DIAGRAM FLUSH WITH THE CONTROL SIDE | | | WALL. | | | PAGES 7.56- 7.59 ELEVATION DETAIL SHOWING THE SHOWER | | | CONTROLS LOCATION, AND THE GRAB BAR AND SEAT | | | REINFORCEMENT DETAILS- PAGES- 6.12-6.13. SHOW THE | | | LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF | | | REINFORCEMENT MATERIAL TO BE USED. SEE SEC 603.1 FBC B | | | FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS. | | | | | | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE | | | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND | | | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE | | | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE | | | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET | | | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY | | | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO | | | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF | | | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, | | | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A | | | COPY OF THE FAIR HOUSING AFFIDAVIT. | | | | | | 4) A-2: PROVIDE A SHOWER PAN DETAIL- SEC. 417.5.1- | | | 417.5.2.6 FBC P. | | | | | | A) REFER TO SEC. 1002.1: THE HORIZONTAL DISTANCE FROM | | | THE CENTERLINE OF THE NEW BATHTUB DRAIN OUTLET TO THE | | | CENTERLINE OF THE INLET OF THE EXISTING TRAPS SHALL NOT | | | EXCEED 30". PLEASE PLACE A NOTE ON THE PLAN INDICATING | | | COMPLIANCE. | | | | | | B) RELOCATING THE SHOWER DRAIN OUTLETS WILL REQUIRE THE | | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | | SEC. 107.2.1 WPB. | | | | | | C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB | | | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE | | | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED | | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SEC. 315.1 | | | FBC P AND SEC. 714.4.1.2 FBC B. | | | | | | 4) DEFERRED SUBMITTALS- SECTION 107.3.4.1 WPB. | | | MANUFACTURER?S SPECIFICATIONS ARE REQUIRED FOR THE | | | SHOWER VALVE- SEC. 412.3 & 412.5 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-11-03 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-11-03 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-11-03 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2022-11-03 12:35:59 | 11/3/22 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS | | | PASSED AND ROUTED TO STORAGE.MP |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-06-29 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-29 11:00:24 | 1) THE 3 SUBMITTED FLOOR PLANS DRAWN BY LYNN AUSTIN | | | WILL HAVE TO HAVE EITHER A ARCHITECT OR ENGINEER CREATE | | | THEIR OWN PLANS. PROJECTS GREATER THAN $25,000.00 ARE | | | REQUIRED TO BE SINGED AND SEALED. 481.229 EXCEPTIONS; | | | EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF | | | BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL, | | | AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE, | | | PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT | | | SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS | | | PURSUANT TO 1013.45. | | | | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2022-05-09 |
Time |
17:14 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-05-09 17:14:38 | | | | 1) THE 3 SUBMITTED FLOOR PLANS DRAWN BY LYNN AUSTIN | | | WILL HAVE TO HAVE EITHER A ARCHITECT OR ENGINEER CREATE | | | THEIR OWN PLANS. PROJECTS GREATER THAN $25,000.00 ARE | | | REQUIRED TO BE SINGED AND SEALED. 481.229 EXCEPTIONS; | | | EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF | | | BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL, | | | AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE, | | | PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT | | | SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS | | | PURSUANT TO 1013.45. | | | | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] |
|
|