Plan Review Details - Permit 22040936
Plan Review Stops For Permit 22040936
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-11-08 Cont ID  
Sent By jwitmer Date 2022-11-08 Time 16:18 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-06-29 Cont ID  
Sent By jwitmer Date 2022-06-29 Time 10:59 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-06-29 10:59:04TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By jwitmer Date 2022-05-09 Time 17:13 Rev Time 0.00
Received By jwitmer Date 2022-05-09 Time 16:42 Sent To  
Notes
2022-05-09 17:13:28TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-11-08 Cont ID  
Sent By jwitmer Date 2022-11-08 Time 16:21 Rev Time 0.00
Received By jwitmer Date 2022-11-08 Time 16:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-06-29 Cont ID  
Sent By jwitmer Date 2022-06-29 Time 10:57 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-06-29 10:57:46WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22040936
 ADD: 701 S OLIVE AVE # 1903
 CONT: STONESTYLES
 TEL: 561-809-5115
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JUNE 29TH/2022
 ACTION: DENIED
  
 1)2ND REQUEST. THE 3 SUBMITTED FLOOR PLANS DRAWN BY
 LYNN AUSTIN WILL HAVE TO HAVE EITHER A ARCHITECT OR
 ENGINEER CREATE THEIR OWN PLANS. PROJECTS GREATER THAN
 $25,000.00 ARE REQUIRED TO BE SIGNED AND SEALED.
 481.229 EXCEPTIONS; EXEMPTIONS FROM LICENSURE (1) (C)
 ANY OTHER TYPE OF BUILDING COSTING LESS THAN
 $25,000.00, EXCEPT A SCHOOL, AUDITORIUM, OR OTHER
 BUILDING INTENDED FOR PUBLIC USE, PROVIDED THAT THE
 SERVICES OF A REGISTERED ARCHITECT SHALL NOT BE
 REQUIRED FOR MINOR SCHOOL PROJECTS PURSUANT TO 1013.45.
  
 2) 2ND REQUEST. IT APPEARS THE PROPOSED FLOOR PLAN AND
 FLOOR PLAN 001 DO NOT MATCH UP, DISCREPANCY IN PLANS.
 SHEET 001 FLOOR PLAN THE MAIN DOUBLE DOOR ENTRY. THE
 CORRIDOR OUTSIDE THE UNIT TURNS 90 DEGREES BUT THE
 FRONT ENTRY DOORS ARE AT A 45 DEGREE ANGLE TO THE
 CORRIDOR, SHEET 003 THE PROPOSED FLOOR PLAN HAS THE
 FRONT ENTRY DOOR PARALLEL TO THE CORRIDOR DISCREPANCY
 IN PLANS. 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
 SHOW AS A FULL FLOOR PLAN WITH CORRIDOR.
  
 3)2ND REQUEST. AS VIEWED FROM PROPOSED FLOOR PLAN THE
 KITCHEN AND BATHROOMS HAVE BEEN REVERED THAT WILL
 CREATE NEW PLUMBING PENETRATIONS OF THE POST TENSIONED
 FLOOR SYSTEM. POST TENSION SLAB/ NEW HOLES. THE PLAN IS
 SILENT AS IF THE LOCATION OF THE EXISTING TUB DRAIN IS
 GOING TO BE REUSED IN THE SAME LOCATION. IF NOT, THEN
 THE FLOOR SLAB WILL NEED TO BE X-RAYED TO FIND THE POST
 TENSION CHORD LOCATIONS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) 2ND REQUEST. -PENETRATIONS FIRESTOP SYSTEMS
 (HORIZONTAL ASSEMBLIES). IF A NEW FLOOR PENETRATION IS
 MADE FOR THE FUTURE SHOWER DRAIN, THEN YOU NEED TO SHOW
 COMPLIANCE WITH THE 2020 FBC-B SECTION 714.5.1.2.
 THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL
 ASSEMBLIES). THROUGH PENETRATIONS SHALL BE PROTECTED BY
 A THROUGH PENETRATION FIRESTOP SYSTEM INSTALLED IN
 ACCORDANCE WITH ASTM E814 OR UL 1479. THE SYSTEM SHALL
 HAVE AN F RATING / T RATING OF NOT LESS THAN 1 HOUR BUT
 NOT LESS THAN THE REQUIRED RATING OF THE FLOOR
 PENETRATED.
  
 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By jwitmer Date 2022-05-09 Time 17:10 Rev Time 0.00
Received By jwitmer Date 2022-05-09 Time 16:42 Sent To  
Notes
2022-05-09 17:12:34WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22040936
 ADD: 701 S OLIVE AVE # 1903
 CONT: STONESTYLES
 TEL: 561-809-5115
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MONDAY MAY 09TH/2022
 ACTION: DENIED
  
 1) THE 3 SUBMITTED FLOOR PLANS DRAWN BY LYNN AUSTIN
 WILL HAVE TO HAVE EITHER A ARCHITECT OR ENGINEER CREATE
 THEIR OWN PLANS. PROJECTS GREATER THAN $25,000.00 ARE
 REQUIRED TO BE SINGED AND SEALED. 481.229 EXCEPTIONS;
 EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF
 BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL,
 AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE,
 PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT
 SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS
 PURSUANT TO 1013.45.
  
 2) IT APPEARS THE PROPOSED FLOOR PLAN AND FLOOR PLAN
 001 DO NOT MATCH UP, DISCREPANCY IN PLANS. SHEET 001
 FLOOR PLAN THE MAIN DOUBLE DOOR ENTRY. THE CORRIDOR
 OUTSIDE THE UNIT TURNS 90 DEGREES BUT THE FRONT ENTRY
 DOORS ARE AT A 45 DEGREE ANGLE TO THE CORRIDOR, SHEET
 003 THE PROPOSED FLOOR PLAN HAS THE FRONT ENTRY DOOR
 PARALLEL TO THE CORRIDOR DISCREPANCY IN PLANS.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 3) AS VIEWED FROM PROPOSED FLOOR PLAN THE KITCHEN AND
 BATHROOMS HAVE BEEN REVERED THAT WILL CREATE NEW
 PLUMBING PENETRATIONS OF THE POST TENSIONED FLOOR
 SYSTEM. POST TENSION SLAB/ NEW HOLES. THE PLAN IS
 SILENT AS IF THE LOCATION OF THE EXISTING TUB DRAIN IS
 GOING TO BE REUSED IN THE SAME LOCATION. IF NOT, THEN
 THE FLOOR SLAB WILL NEED TO BE X-RAYED TO FIND THE POST
 TENSION CHORD LOCATIONS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 4) THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL
 ASSEMBLIES). IF A NEW FLOOR PENETRATION IS MADE FOR THE
 FUTURE SHOWER DRAIN, THEN YOU NEED TO SHOW COMPLIANCE
 WITH THE 2020 FBC-B SECTION 714.5.1.2.
 THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL
 ASSEMBLIES). THROUGH PENETRATIONS SHALL BE PROTECTED BY
 A THROUGH PENETRATION FIRESTOP SYSTEM INSTALLED IN
 ACCORDANCE WITH ASTM E814 OR UL 1479. THE SYSTEM SHALL
 HAVE AN F RATING / T RATING OF NOT LESS THAN 1 HOUR BUT
 NOT LESS THAN THE REQUIRED RATING OF THE FLOOR
 PENETRATED.
  
 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-11-28 Cont ID  
Sent By mpeterso Date 2022-11-28 Time 14:22 Rev Time 0.00
Received By mpeterso Date 2022-11-28 Time 14:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-30 Cont ID  
Sent By mpeterso Date 2022-06-30 Time 11:22 Rev Time 0.00
Received By mpeterso Date 2022-06-30 Time 11:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-19 Cont ID  
Sent By mpeterso Date 2022-05-19 Time 11:48 Rev Time 0.00
Received By mpeterso Date 2022-05-19 Time 11:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By pleduc Date 2022-06-23 Time   Rev Time 0.00
Received By pleduc Date 2022-06-23 Time 10:57 Sent To  
Notes
2022-06-23 11:01:21FIRE PROVISO:
  
 THERE ARE INDICATIONS OF WALLS BEING REMOVED THAT MAY
 AFFECT THE REQUIRED FIRE SPRINKLER HEAD COVERAGE.
  
 A FIRE SPRINKLER CONTRACTOR IS REQUIRED TO REVIEW THE
 PROPOSED WORK TO ENSURE CODE COMPLIANT COVERAGE IS
 MAINTAINED.
  
 SHOULD NO WORK BE REQUIRED, A LETTER FROM THAT
 CONTRACTOR WILL BE REQUIRED TO BE SUBMITTED ON FINAL
 FIRE INSPECTIONS TO THE FIRE INSPECTOR.
  
 SHOULD MODIFICATION BE REQUIRED IT SHALL BE UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS.
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-04-21 Cont ID  
Sent By pleduc Date 2022-04-21 Time   Rev Time 0.00
Received By pleduc Date 2022-04-21 Time 11:24 Sent To  
Notes
2022-04-21 13:32:12FIRE PROVISO:
  
 THERE ARE INDICATIONS OF WALLS BEING REMOVED THAT MAY
 AFFECT THE REQUIRED FIRE SPRINKLER HEAD COVERAGE.
  
 A FIRE SPRINKLER CONTRACTOR IS REQUIRED TO REVIEW THE
 PROPOSED WORK TO ENSURE CODE COMPLIANT COVERAGE IS
 MAINTAINED.
  
 SHOULD NO WORK BE REQUIRED, A LETTER FROM THAT
 CONTRACTOR WILL BE REQUIRED TO BE SUBMITTED ON FINAL
 FIRE INSPECTIONS TO THE FIRE INSPECTOR.
  
 SHOULD MODIFICATION BE REQUIRED IT SHALL BE UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS.
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-28 Cont ID  
Sent By mpeterso Date 2022-11-28 Time 14:22 Rev Time 0.00
Received By mpeterso Date 2022-11-03 Time 06:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-30 Cont ID  
Sent By mpeterso Date 2022-06-30 Time 11:22 Rev Time 0.00
Received By mpeterso Date 2022-06-22 Time 07:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-19 Cont ID  
Sent By mpeterso Date 2022-05-19 Time 11:49 Rev Time 0.00
Received By mpeterso Date 2022-04-21 Time 05:58 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-05-09 Cont ID  
Sent By jwitmer Date 2022-05-09 Time 17:12 Rev Time 0.00
Received By jwitmer Date 2022-05-09 Time 16:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-05-05 Cont ID  
Sent By medwards Date 2022-05-05 Time 17:10 Rev Time 0.00
Received By medwards Date 2022-05-05 Time 17:10 Sent To  
Notes
2022-05-05 17:10:41NO MECHANICAL WORK SHOWN FOR THIS PROJECT. ME

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-11-04 Cont ID  
Sent By ccole Date 2022-11-04 Time 15:26 Rev Time 0.00
Received By ccole Date 2022-11-04 Time 14:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-06-24 Cont ID  
Sent By ccole Date 2022-06-24 Time 16:31 Rev Time 0.00
Received By ccole Date 2022-06-24 Time 16:04 Sent To  
Notes
2022-06-24 16:31:442ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22040936
 6/24//22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES.
  
 1) FAILED. PLUMBING PLANS SHALL BE DRAWN BY THE
 PLUMBING CONTRACTOR OF RECORD OR A FL. LICENSED
 ENGINEER- FLORIDA STATUTES 471.003(2) (H) & 471.015.
 CONTRACTOR PLANS SHALL BEAR THE PRINTED NAME, LICENSE
 NUMBER, AND SIGNATURE OF THE PLUMBING CONTRACTOR OF
 RECORD- SEC. 107.2.1 WPB. PLUMBING PLAN P2 NOT SIGNED.
  
 2) FAILED. THE PLUMBING PLANS SHALL INCLUDE A SCOPE OF
 WORK OUTLINE ITEMIZING ALL REPLACED FIXTURES AND
 LOCATIONS OF NEW, REPLACED, RELOCATED PLUMBING PIPING.
 PLUMBING RISER DRAWINGS ARE REQUIRED FOR ALL NEW WATER
 SUPPLY AND SANITARY DRAINAGE AND VENT PIPING
 INSTALLATIONS- SEC. 107.2.1 AND 107.3.5.3.13 WPB. NOT
 PROVIDED.
  
 3) FAILED. NO DETAILS PROVIDED FOR THE GUEST BATH
 REMODEL. FAIR HOUSING COMPLIANCE:
 WPB BUILDING DEPT. RECORDS INDICATE THE RESIDENTIAL
 UNITS AT TWO CITY PLAZA- 701 S OLIVE WERE DESIGNED AND
 CONSTRUCTED IN ACCORDANCE WITH THE FAIR HOUSING DESIGN
 ACT. THE PROPOSED KITCHEN AND BATH ALTERATIONS SHALL BE
 DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE FHDA
 MANUAL OR THE FAIR HOUSING DESIGN GUIDELINES CONTAINED
 IN THE FBC ACC. THE DESIGNER SHALL INDICATE COMPLIANCE
 WITH SPECIFICATION TYPE A OR B AND THE DRAWINGS SHALL
 REFLECT THE SPECIFICATION. PLEASE REFER TO PAGES 7.34-
 7.39 OF THE FHDA MANUAL FOR EXPLANATORY INFORMATION.
 KITCHEN- REFER TO PAGE 7.5 OF THE FAIR HOUSING ACT
 DESIGN MANUAL AND REQUIREMENT 7 (1)(A) OF THE
 GUIDELINES AND SHOW THE REQUIRED 30X48 INCH CLEAR FLOOR
 SPACE DIAGRAM AND DIMENSIONS FOR A PARALLEL WHEELCHAIR
 APPROACH AT THE SINK, AND 30X48 INCH CLEAR FLOOR SPACE
 DIAGRAM AND DIMENSION FOR THE PARALLEL OR FORWARD
 APPROACH TO THE DISHWASHER. PLEASE NOTE THAT THE
 REQUIRED CLEAR FLOOR SPACES FOR PARALLEL APPROACHES
 SHALL BE CENTERED ON THE SINK AND DISHWASHER.
 PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND
 APPLIANCES
 PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND
 ALL OPPOSING ELEMENTS.
 PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET
 DOORS INCLUDING KNEE SPACES.
 BATH-
 PAGES 7.56- 7.59 INTERIOR FINISH DIMENSIONS OF THE
 SHOWER- WIDTH AND DEPTH.
 PAGES 7.56- 7.59 REQUIRED 30X48-INCH CLEAR FLOOR SPACE
 PARALLEL APPROACH DIAGRAM FLUSH WITH THE CONTROL SIDE
 WALL.
 PAGES 7.56- 7.59 ELEVATION DETAIL SHOWING THE SHOWER
 CONTROLS LOCATION, AND THE GRAB BAR AND SEAT
 REINFORCEMENT DETAILS- PAGES- 6.12-6.13. SHOW THE
 LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF
 REINFORCEMENT MATERIAL TO BE USED. SEE SEC 603.1 FBC B
 FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 4) FAILED A, B, & C. A-2: PROVIDE A SHOWER PAN DETAIL-
 SEC. 417.5.1- 417.5.2.6 FBC P.
  
 A) REFER TO SEC. 1002.1: THE HORIZONTAL DISTANCE FROM
 THE CENTERLINE OF THE NEW BATHTUB DRAIN OUTLET TO THE
 CENTERLINE OF THE INLET OF THE EXISTING TRAPS SHALL NOT
 EXCEED 30". PLEASE PLACE A NOTE ON THE PLAN INDICATING
 COMPLIANCE.
  
 B) RELOCATING THE SHOWER DRAIN OUTLETS WILL REQUIRE THE
 FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING
 STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A
 NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET-
 SEC. 107.2.1 WPB.
  
 C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB
 WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE
 AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SEC. 315.1
 FBC P AND SEC. 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-03 Cont ID  
Sent By ccole Date 2022-05-03 Time 15:34 Rev Time 0.00
Received By ccole Date 2022-05-03 Time 13:58 Sent To  
Notes
2022-05-03 15:34:231ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22040936
 5/3/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLUMBING PLANS SHALL BE DRAWN BY THE PLUMBING
 CONTRACTOR OF RECORD OR A FL. LICENSED ENGINEER-
 FLORIDA STATUTES 471.003(2) (H) & 471.015. CONTRACTOR
 PLANS SHALL BEAR THE PRINTED NAME, LICENSE NUMBER, AND
 SIGNATURE OF THE PLUMBING CONTRACTOR OF RECORD- SEC.
 107.2.1 WPB.
  
 2) THE PLUMBING PLANS SHALL INCLUDE A SCOPE OF WORK
 OUTLINE ITEMIZING ALL REPLACED FIXTURES AND LOCATIONS
 OF NEW, REPLACED, RELOCATED PLUMBING PIPING. PLUMBING
 RISER DRAWINGS ARE REQUIRED FOR ALL NEW WATER SUPPLY
 AND SANITARY DRAINAGE AND VENT PIPING INSTALLATIONS-
 SEC. 107.2.1 AND 107.3.5.3.13 WPB.
  
 3) FAIR HOUSING COMPLIANCE:
 WPB BUILDING DEPT. RECORDS INDICATE THE RESIDENTIAL
 UNITS AT TWO CITY PLAZA- 701 S OLIVE WERE DESIGNED AND
 CONSTRUCTED IN ACCORDANCE WITH THE FAIR HOUSING DESIGN
 ACT. THE PROPOSED KITCHEN AND BATH ALTERATIONS SHALL BE
 DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE FHDA
 MANUAL OR THE FAIR HOUSING DESIGN GUIDELINES CONTAINED
 IN THE FBC ACC. THE DESIGNER SHALL INDICATE COMPLIANCE
 WITH SPECIFICATION TYPE A OR B AND THE DRAWINGS SHALL
 REFLECT THE SPECIFICATION. PLEASE REFER TO PAGES 7.34-
 7.39 OF THE FHDA MANUAL FOR EXPLANATORY INFORMATION.
 KITCHEN- REFER TO PAGE 7.5 OF THE FAIR HOUSING ACT
 DESIGN MANUAL AND REQUIREMENT 7 (1)(A) OF THE
 GUIDELINES AND SHOW THE REQUIRED 30X48 INCH CLEAR FLOOR
 SPACE DIAGRAM AND DIMENSIONS FOR A PARALLEL WHEELCHAIR
 APPROACH AT THE SINK, AND 30X48 INCH CLEAR FLOOR SPACE
 DIAGRAM AND DIMENSION FOR THE PARALLEL OR FORWARD
 APPROACH TO THE DISHWASHER. PLEASE NOTE THAT THE
 REQUIRED CLEAR FLOOR SPACES FOR PARALLEL APPROACHES
 SHALL BE CENTERED ON THE SINK AND DISHWASHER.
 PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND
 APPLIANCES
 PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND
 ALL OPPOSING ELEMENTS.
 PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET
 DOORS INCLUDING KNEE SPACES.
 BATH-
 PAGES 7.56- 7.59 INTERIOR FINISH DIMENSIONS OF THE
 SHOWER- WIDTH AND DEPTH.
 PAGES 7.56- 7.59 REQUIRED 30X48-INCH CLEAR FLOOR SPACE
 PARALLEL APPROACH DIAGRAM FLUSH WITH THE CONTROL SIDE
 WALL.
 PAGES 7.56- 7.59 ELEVATION DETAIL SHOWING THE SHOWER
 CONTROLS LOCATION, AND THE GRAB BAR AND SEAT
 REINFORCEMENT DETAILS- PAGES- 6.12-6.13. SHOW THE
 LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF
 REINFORCEMENT MATERIAL TO BE USED. SEE SEC 603.1 FBC B
 FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 4) A-2: PROVIDE A SHOWER PAN DETAIL- SEC. 417.5.1-
 417.5.2.6 FBC P.
  
 A) REFER TO SEC. 1002.1: THE HORIZONTAL DISTANCE FROM
 THE CENTERLINE OF THE NEW BATHTUB DRAIN OUTLET TO THE
 CENTERLINE OF THE INLET OF THE EXISTING TRAPS SHALL NOT
 EXCEED 30". PLEASE PLACE A NOTE ON THE PLAN INDICATING
 COMPLIANCE.
  
 B) RELOCATING THE SHOWER DRAIN OUTLETS WILL REQUIRE THE
 FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING
 STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A
 NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET-
 SEC. 107.2.1 WPB.
  
 C) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB
 WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE
 AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SEC. 315.1
 FBC P AND SEC. 714.4.1.2 FBC B.
  
 4) DEFERRED SUBMITTALS- SECTION 107.3.4.1 WPB.
 MANUFACTURER?S SPECIFICATIONS ARE REQUIRED FOR THE
 SHOWER VALVE- SEC. 412.3 & 412.5 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-11-03 Cont ID  
Sent By mpeterso Date 2022-11-03 Time 12:35 Rev Time 0.00
Received By mpeterso Date 2022-11-03 Time 12:35 Sent To  
Notes
2022-11-03 12:35:5911/3/22 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS
 PASSED AND ROUTED TO STORAGE.MP

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-06-29 Cont ID  
Sent By jwitmer Date 2022-06-29 Time 11:00 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-06-29 11:00:241) THE 3 SUBMITTED FLOOR PLANS DRAWN BY LYNN AUSTIN
 WILL HAVE TO HAVE EITHER A ARCHITECT OR ENGINEER CREATE
 THEIR OWN PLANS. PROJECTS GREATER THAN $25,000.00 ARE
 REQUIRED TO BE SINGED AND SEALED. 481.229 EXCEPTIONS;
 EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF
 BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL,
 AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE,
 PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT
 SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS
 PURSUANT TO 1013.45.
  
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By jwitmer Date 2022-05-09 Time 17:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-05-09 17:14:38 
 1) THE 3 SUBMITTED FLOOR PLANS DRAWN BY LYNN AUSTIN
 WILL HAVE TO HAVE EITHER A ARCHITECT OR ENGINEER CREATE
 THEIR OWN PLANS. PROJECTS GREATER THAN $25,000.00 ARE
 REQUIRED TO BE SINGED AND SEALED. 481.229 EXCEPTIONS;
 EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF
 BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL,
 AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE,
 PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT
 SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS
 PURSUANT TO 1013.45.
  
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]