Plan Review Details - Permit 22040845
Plan Review Stops For Permit 22040845
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-07-19 Cont ID  
Sent By jbrooks Date 2022-07-19 Time 11:38 Rev Time 0.00
Received By jbrooks Date 2022-07-19 Time 07:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-06-06 Cont ID  
Sent By jbrooks Date 2022-06-06 Time 14:30 Rev Time 0.00
Received By jbrooks Date 2022-06-06 Time 12:44 Sent To  
Notes
2022-06-06 14:31:10JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC B 107.2.1 THE CITY OF WEST PALM BEACH IS NOT
 LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 150. PROVIDE
 A COMPLETE SET OF 2020 CODE VERSION PRODUCT
 APPROVALS/NOA'S FOR THE PROPOSED FLAT ROOF SYSTEM TO BE
 USED. INCLUDE COVER PAGE, EVALUATION REPORTS AND
 INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 2. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT
 LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 128. SUBMIT
 FASTENER DENSITY CALCULATIONS PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER,
 REGISTERED ARCHITECT, OR REGISTERED ROOF CONSULTANT.
 3. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020
 CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED
 HIP & RIDGE METAL TO BE USED. (FL5374-R6)
 4. FBC B 107.3.4.1. SUBMITTED MIAMI-DADE COUNTY NOA
 NO.: 20-1124.07, MIAMI-DADE COUNTY NOA NO.: 21-0602.14,
 MIAMI-DADE COUNTY NOA NO.: 21-0420.04, PRODUCT APPROVAL
 FL12328-R9 ALONG WITH THE 2020 CODE VERSION PRODUCT
 APPROVALS/NOA'S FOR THE PROPOSED HIP & RIDGE METAL &
 THE 2020 CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE
 PROPOSED FLAT ROOF SYSTEM TO BE USED SHALL BE SUBMITTED
 TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE
 CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE
 BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND
 FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE
 BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE
 INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN APPROVED BY THE BUILDING OFFICIAL. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-19 Cont ID  
Sent By jbrooks Date 2022-07-19 Time 11:39 Rev Time 0.00
Received By jbrooks Date 2022-07-06 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-06 Cont ID  
Sent By jbrooks Date 2022-06-06 Time 14:31 Rev Time 0.00
Received By jbrooks Date 2022-04-20 Time 07:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-19 Cont ID  
Sent By jbrooks Date 2022-07-19 Time 11:39 Rev Time 0.00
Received By jbrooks Date 2022-07-19 Time 11:39 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved