Plan Review Details - Permit 22040589
Plan Review Stops For Permit 22040589
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-25 Cont ID  
Sent By rcaranci Date 2022-04-25 Time 16:31 Rev Time 0.00
Received By rcaranci Date 2022-04-14 Time 06:34 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2022-04-25 Cont ID  
Sent By rcaranci Date 2022-04-25 Time 16:31 Rev Time 0.00
Received By rcaranci Date 2022-04-25 Time 16:31 Sent To  
Notes
2022-04-25 16:40:19RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
  
 1. SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
  
 SHOW ALL CALCULATIONS FOR OPEN SPACE.
  
  
 2. ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE
 OR PORTION THEREOF
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 SHOW CALCULATIONS FOR NUMBER OF REQUIRED AND PROVIDED
 TREES AND SHRUBS BASED ON OPEN SPACE.
  
 3. SECTION 94-442 (D) SUBSTITUTION OF PALM TREES.
 PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35
 PERCENT OF THE SHADE OR FLOWERING TREES REQUIRED BY
 THIS ARTICLE. HOWEVER, WHEN PALM TREES ARE SUBSTITUTED
 FOR SHADE TREES, THREE PALM TREES SHALL BE PROVIDED FOR
 EACH REQUIRED SHADE TREE. THIS 3:1 SUBSTITUTION SHALL
 NOT BE REQUIRED FOR ROYAL PALM TREES (ROYSTONEA SPP.),
 SENEGAL DATE PALM (PHOENIX RECLINATA), MEDJOOL DATE
 PALM (PHOENIX DACTYLIFERA), BISMARCK PALM (BISMARCKIA
 NOBILIS), AND SILVER DATE PALM (PHOENIX SYLVESTRIS).
  
 PROVIDE THE NUMBER OF PALMS SUBSTITUTED FOR REQUIRED
 TREES. NO TREES ARE SHOWN ON THE PLAN SUBMITTED, ONLY
 PALMS.
  
 4. SECTION 94-442 (G) FLORIDA FRIENDLY LANDSCAPE
 REQUIREMENTS
 LANDSCAPE PLAN MUST SATISFY A MINIMUM TOTAL OF 25
 POINTS FROM THE DESIGN OPTIONS CHART.
  
  
 5. SECTION 94-445 (4) REQUIRED PLANT MATERIAL
 SPECIFICATIONS.
 SHADE AND FLOWERING TREES MINIMUM 12 FEET IN HEIGHT AND
 FLORIDA GRADE #1 OR BETTER QUALITY.
 PALM SPECIES MINIMUM EIGHT FEET CLEAR WOOD.
 SHRUBS MINIMUM OF 3 GALLON, GROUNDCOVER MAY BE SMALLER.
  
 TREES MUST MEET SIZE AND GRADE SPECIFICATIONS TO
 QUALIFY TOWARD REQUIREMENTS.
  
  
 6. SECTION 94-445 I.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES.
  
 PROVIDE A PLANT LIST AND SHOW PERCENTAGE BASED ON PLANT
 LIST.
  
 7. SECTION 94-482 PARKING REQUIREMENTS FOR LESS THAN
 THREE RESIDENTIAL DWELLING UNITS.(A). REQUIRED PARKING
 MAY BE LOCATED IN THE FRONT YARD; HOWEVER, THE LESSER
 OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT YARD
 AREA SHALL BE LANDSCAPED WITH LIVING PLANT MATERIAL
 (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES, VINES OR
 TREES).
  
 DRIVEWAY LAYOUT SHOWN DOES NOT APPEAR TO MEET THE
 LANDSCAPE REQUIREMENTS. SUBMIT A DRIVEWAY PERMIT WITH
 PLAN THAT MEETS REQUIREMENTS AND INCLUDE MATCHING
 DRIVEWAY LAYOUT ON LANDSCAPE PLAN.
  
 8. SHOW ALL UTILITY EASEMENTS AND ANY OVERHEAD UTILITY
 LINES AND RESOLVE ANY CONFLICTS WITH TREE SPECIES AND
 LOCATIONS ADJACENT TO POWER LINES.
  
 9. INDICATE THE EXAXT LIMITS OF THE SYNTHETIC TURF
 LOCATION AND PROVIDE PRODUCT INFORMATION AS REQUIRED BY
 SECTION 94-451 (E) MINIMUM MATERIAL STANDARDS.
  

Review Stop Z ZONING
Rev No 1 Status N Date 2022-04-25 Cont ID  
Sent By rcaranci Date 2022-04-25 Time 16:31 Rev Time 0.00
Received By rcaranci Date 2022-04-25 Time 16:31 Sent To  
Notes
***NONE***