Plan Review Details - Permit 22040542
Plan Review Stops For Permit 22040542
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-08-10 Cont ID  
Sent By cpuell Date 2022-08-10 Time 11:31 Rev Time 0.00
Received By cpuell Date 2022-08-10 Time 11:31 Sent To  
Notes
2022-08-10 11:31:14ADDRESS UPDATED TO 132 VALENCIA RD

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-04-27 Cont ID  
Sent By cpuell Date 2022-04-27 Time 15:27 Rev Time 0.00
Received By cpuell Date 2022-04-27 Time 15:27 Sent To  
Notes
2022-04-27 15:27:29MAIN ENTRANCE FACES VALENCIA RD, THE ADDRESS FOR THE
 PROPERTY WILL NEED TO BE CHANGED TO VALENCIA RD. PLEASE
 HAVE OWNER CONTACT [email protected] OR CALL 561-805-6659
 TO DISCUSS ADDRESSING OPTIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 16:22 Rev Time 0.00
Received By rmcphers Date 2022-10-07 Time 16:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-09-07 Cont ID  
Sent By rmcphers Date 2022-09-07 Time 14:38 Rev Time 0.00
Received By rmcphers Date 2022-09-07 Time 14:38 Sent To  
Notes
2022-09-07 15:04:27NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE FRONT PAGES OF THE FLORIDA
 PRODUCT APPROVALS FL10765, FL11002, FL18655, FL21061,
 FL21195, FL5259, FL15279, FL6332 AND FL17908. FRONT
 PAGES ARE NEEDED TO DETERMINE IF THE PRODUCT IS
 APPROVED BY THE FLORIDA PRODUCT APPROVAL SYSTEM.
  
 2) DOOR AND WINDOW OPENING WIND PRESSURES SHOULD BE
 SHOWN - WHEN USING THE WIND DESIGN PRESSURES IN FBC
 TABLER301.2(2) - SOME OF THE PRODUCT APPROVALS FOR THE
 WINDOWS AND DOORS IN WIND ZONE 5 MAY NOT MEET THE
 REQUIRED WIND PRESSURES - PLEASE AT LEAST SHOW BUILDING
 WIND ZONE 5 LOCATIONS.
  
 3) THE DRAWINGS PROVIDED FOR THE OVERHEAD DOOR PRODUCT
 APPROVAL FL15279 ARE FOR A 16' WIDE DOOR (DRAWINGS SHOW
 DOOR TO BE 18' WIDE) AND DO NOT MEET THE REQUIRED WIND
 DESIGN PRESSURES PER FBC TABLER301.2(2)
  
 4) THE DRAWINGS PROVIDED FOR PRODUCT APPROVAL FL11002 -
 CASEMENT WINDOWS DO NOT MEET IMPACT REQUIREMENTS -
 PLEASE PROVIDE THE REQUIRED SHUTTER PRODUCT APPROVALS.
  
 5) CANNOT FIND PRODUCT APPROVAL FL20107 FOR THE
 NANAWALL DOOR IN PROJECTDOX - AS LISTED ON THE DRAWINGS
 DOOR SCHEDULE.
  
 6) DRAWING A403 SAYS TO SEE CUT SECTION A-502 - DRAWING
 A-502 IS NOT IN PROJECTDOX.
  
 7) DRAWING A-403 SHOWS A GUARD HEIGHT OF 2'10" (PLEASE
 SHOW GUARD HEIGHT TO COMPLY WITH FBC R312.1.2) -
 DRAWING A-401 SHOWS AN ADDED RAILING WITH A HEIGHT OF
 3' FOR THE GUARD HEIGHT (PLEASE SHOW ALL GUARD RAIL
 HEIGHTS)
  
 8) PROPOSED ELEVATION OF THE MECHANICAL EQUIPMENT
 SERVICING THE BUILDING SHOULD BE SHOWN ON THE DRAWINGS
 FBC R322.1.6
  
 9) ELEVATION CERTIFICATE - DOES NOT SHOW AS
 DIGITALLY/ELECTRONICALLY SIGNED.
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-08-18 Cont ID  
Sent By rmcphers Date 2022-08-18 Time 10:16 Rev Time 0.00
Received By rmcphers Date 2022-08-18 Time 10:16 Sent To  
Notes
2022-08-18 10:30:42NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE FRONT PAGES OF THE FLORIDA
 PRODUCT APPROVALS FL18655, FL21061, FL21195, FL5259,
 FL15279, FL6332 AND FL17908. FRONT PAGES ARE NEEDED TO
 DETERMINE IF THE PRODUCT IS APPROVED BY THE FLORIDA
 PRODUCT APPROVAL SYSTEM.
  
 2) PLEASE PROVIDE A NOTE ON THE DRAWINGS FOR THE
 TERMITE PROTECTION - FBC R318
  
 3) THE ELEVATION CERTIFICATE NEEDS CORRECTIONS - C2(A)
 ELEVATION SHOWN SHOULD BE THE LOWEST FLOOR ELEVATION
 (LIVING ROOM IS LOWER THAN MAIN HOUSE) - FBC
 107.3.5.1.1
  
 4) DRAWING A-101.1 SHOWS THE GARAGE FLOOR AT 9.00 AT
 THE DOOR TO THE LIVING SPACE - - PLEASE SHOW THE LOWEST
 FLOOR ELEVATION AT THE OVERHEAD DOOR OPENING - - OR YOU
 WILL NEED TO SHOW FLOOD VENTS PER FBC R322.2.2 -
  
 5) UNABLE TO FIND THE INTERIOR DOOR SCHEDULE - R302.5.1
 OPENING PROTECTION.
 OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM
 USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED.
 OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL
 BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 13/8
 INCHES (35 MM) IN THICKNESS, SOLID OR HONEYCOMBCORE
 STEEL DOORS NOT LESS THAN 13/8 INCHES (35 MM) THICK, OR
 20-MINUTE FIRE-RATED DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-07 Cont ID  
Sent By rmcphers Date 2022-07-07 Time 10:49 Rev Time 0.00
Received By rmcphers Date 2022-07-06 Time 14:06 Sent To  
Notes
2022-07-07 10:42:43NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE FRONT PAGES OF THE FLORIDA
 PRODUCT APPROVALS LISTED ON THE DRAWINGS. FRONT PAGES
 ARE NEEDED TO DETERMINE IF THE PRODUCT IS APPROVED BY
 THE FLORIDA PRODUCT APPROVAL SYSTEM.
  
 2) PLEASE SHOW THE SITE STORM WATER DRAINAGE ON THE
 SITE PLAN OR PROVIDE A SEPARATE STORM WATER PLAN. FBC
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY. (PLEASE PROVIDE CUT
 SECTIONS FOR ANY PROPOSED WATER RETAINING SWALES)
  
 3) PLEASE SHOW THE TYPE OF TERMITE PROTECTION - FBC
 R318
  
 4) DRAWING S-500 ROOF WIND LOADS - PLEASE SHOW THE WIND
 PRESSURES FOR ALL ROOF ZONES INVOLVED
 (1,2E,2N,2R,3,3E,3R ETC..) PER FBC TABLE R301.2(2)
  
 5) ON THE PROVIDED ROOF TILE UNDERLAYMENT PRODUCT
 APPROVAL - THERE ARE MANY DIFFERENT SYSTEMS TO BE USED
 - PLEASE CIRCLE THE ROOF SYSTEM TO BE USED ON THE
 PRODUCT APPROVAL MAKING SURE THAT THE WIND PRESSURE
 MEETS THE REQUIRED WIND PRESSURE PER THE DRAWINGS.
  
 6) THE NANA FOLDING DOOR PRODUCT APPROVAL PROVIDED HAS
 A HEIGHT LIMIT AT 8' - THE DRAWINGS SHOW THE DOOR TO BE
 10' HIGH - PLEASE CLARIFY.
  
 7) PLEASE SHOW THE EQUIPMENT PAD ELEVATIONS TO MEET THE
 FEMA AND CITY ORD. REQUIREMENTS (2' ABOVE BASE FLOOD
 ELEVATION) SEC. 18-296 (A) (5) AND FBC R322.1.6
  
 8) PLEASE PROVIDE A PROPOSED ELEVATION CERTIFICATE -
 FBC 107.3.5.1.1
  
 9) A SEPARATE PERMIT IS REQUIRED FOR - EXISTING
 BUILDING DEMO, POOL LOGGIA, SITEWALL, FENCING. PLEASE
 ACKNOWLEDGE THIS.
  
 10) STRUCTURAL DRAWINGS SHOW A SLOPE ON THE GARAGE SLAB
 AS IT SHOULD - PLEASE SHOW THE LOWEST FLOOR ELEVATION
 AT THE DOOR OPENING - - OR YOU WILL NEED TO SHOW FLOOD
 VENTS PER FBC R322.2.2 - ELEVATION OF THE MIN. 9.00
 NAVD IS SHOWN IN THE CENTER OF THE GARAGE - NEAR THE
 DOOR WILL BE LOWER THAN THE 2' ABOVE FEMA BASE FLOD
 ELEVATION - WHICH WILL REQUIRE FLOOD VENTS FOR THE
 GARAGE WALLS.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-09-15 Cont ID  
Sent By mpeterso Date 2022-09-15 Time 15:49 Rev Time 0.00
Received By mpeterso Date 2022-09-15 Time 15:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2022-08-17 Cont ID  
Sent By mpeterso Date 2022-08-17 Time 09:05 Rev Time 0.00
Received By mpeterso Date 2022-08-17 Time 09:05 Sent To  
Notes
2022-08-17 09:06:28ELECTRIC REVIEW FAILED
 1) CONDUCTORS DETAILED, ON SHEET E 100, AS 2 SETS OF
 1/0, WITH AN MAXIMUM AMPACITY OF 300 AMPS, BETWEEN ATS,
 AND LOAD CENTER, A, ARE INCORRECTLY SIZED, AS PER NEC
 310.15 (B)(7)(2) AND NEC 110.14 (C)(1)(B)(1) AND (2).
 CONDUCTORS OVER 100 AMPERES SHALL BE LIMITED TO SIZING
 AT 75 DEGREE C TEMPERATURES AND SERVICE CONDUCTORS OR
 FEEDERS SERVING THE ENTIRE LOAD OF A SINGLE-FAMILY
 DWELLING SHALL BE SIZED AT 83% OF THE SERVICE RATING.
 THESE CONDUCTORS SHOULD BE SIZED FOR A MINIMUM AMPACITY
 OF 400 AMP X 83% = 332 AMPS. PLEASE CORRECT CONDUCTOR
 SIZE AS APPLICABLE.
 2) CONDUCTORS DETAILED, ON SHEET E 100, AS 2/0, WITH A
 MAXIMUM AMPACITY OF 175 AMPS, BETWEEN LOAD CENTER, A,
 AND LOAD CENTER, MP, ARE INCORRECTLY SIZED, AS PER NEC
 310.15 AND NEC 110.14 (C)(1)(B)(1) AND (2). CONDUCTORS
 OVER 100 AMPERES SHALL BE LIMITED TO SIZING AT 75
 DEGREE C TEMPERATURES AND SERVICE CONDUCTORS OR
 FEEDERS, ONLY, SERVING THE ENTIRE LOAD OF A
 SINGLE-FAMILY DWELLING SHALL BE SIZED AT 83% OF THE
 SERVICE RATING. THESE CONDUCTORS DO NOT FEED THE ENTIRE
 LOAD OF THE DWELLING, AND, THEREFORE, MUST BE SIZED AT
 100 %. THESE CONDUCTORS SHOULD BE SIZED FOR A MINIMUM
 AMPACITY OF 200 AMPERES. PLEASE CORRECT CONDUCTOR SIZE
 AS APPLICABLE.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-05-24 Cont ID  
Sent By mpeterso Date 2022-05-24 Time 09:42 Rev Time 0.00
Received By mpeterso Date 2022-05-24 Time 08:08 Sent To  
Notes
2022-05-24 09:43:29ELECTRIC REVIEW FAILED
 1) IT APPEARS THE ELECTRICAL RISER DIAGRAM IS
 ATTEMPTING TO DETAIL A 300 AMP SERVICE. THE METER MAIN
 IS DETAILED AS 400-AMP. PLEASE DETAIL THE OVERCURRENT
 PROTECTION IN THIS METER MAIN AS 300-AMP OR DETAIL HOW
 THIS RISER COMPLIES WITH NEC 110.3, NEC 310.15
 2) PLEASE DETAIL CONDUCTOR SIZES BETWEEN METER MAIN AND
 ATS. NEC 215.5
 3) IT APPEARS LOAD CENTER B IS FED WITH INCORRECT SIZED
 CONDUCTORS. PLEASE DETAIL CORRECT SIZED CONDUCTORS OR
 DETAIL HOW THESE CONDUCTORS COMPLY WITH NEC 310.15
 (B)(7)(2). PLEASE NOTE IN ORDER FOR FEEDER OR SERVICE
 CONDUCTORS TO BE REDUCED IN AMPACITY TO 83%, THEY MUST
 SERVE THE ENTIRE LOAD ASSOCIATED WITH THE STRUCTURE
 4) PLEASE PROVIDE PANEL SCHEDULES FOR ALL LOAD CENTERS.
 NEC 215.5 AND FBC 107.2
 5) PLEASE DETAIL GROUNDING ELECTRODE SYSTEM FOR LOAD
 CENTER PH OR DETAIL HOW THIS PANEL COMPLIES WITH NEC
 250.32
 6) PLEASE DETAIL NOTES STATING GENERATOR, POOL, AND LOW
 VOLTAGE WIRING REQUIRES A SEPARATE PERMIT
 7) PLEASE DETAIL THE REQUIRED RECEPTACLE AT CONDENSING
 UNITS AS REQUIRED BY NEC 210.63
 8) PLEASE DETAIL ELEVATOR LOAD IN LOAD CALCULATIONS.
 NEC 215.5
 9) PLEASE PROVIDE ELEVATOR SPECIFICATIONS. FBC 107.2
 10) PLEASE DETAIL SMOKE/CARBON ALARMS AS REQUIRED
 R315.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop G GAS REVIEW
Rev No 4 Status P Date 2022-10-14 Cont ID  
Sent By rwbrown Date 2022-10-14 Time 12:01 Rev Time 0.00
Received By rwbrown Date 2022-10-14 Time 12:00 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2022-10-12 Cont ID  
Sent By rwbrown Date 2022-10-12 Time 13:16 Rev Time 0.00
Received By rwbrown Date 2022-10-12 Time 13:16 Sent To  
Notes
2022-10-12 13:19:513RD GAS REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC G2415.11 - THE PORTION OF GAS LINE TO THE
 TANKLESS WATER HEATER IS STILL SHOWN AS GALVANIZED AND
 IS NOT APPROVED FOR UNDERGROUND, EVEN WHEN ENCASED IN A
 SLEEVE IT IS STILL NOT ALLOWED UNDERGROUND. IT WOULD
 ONLY BE ALLOWED UNDERGROUND IF IF WAS PROTECTED PER
 G2415.11.2. TYPICALLY IT WOULD TRANSITION TO CSST
 OUTSIDE AND USE AN APPROVED UNDERGROUND TYPE OF CSST.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-10-07 Cont ID  
Sent By rwbrown Date 2022-10-07 Time 10:33 Rev Time 0.00
Received By rwbrown Date 2022-10-07 Time 10:33 Sent To  
Notes
2022-10-07 10:45:433RD GAS REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
  
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 THE CHANGES MADE HAVE CREATED NEW COMMENTS.
  
 1. 2020 FRC G2415.11.1 - IT APPEARS THAT THE PORTION OF
 PIPING GOING TO TWH1 IS GALVANIZED. GALVANIZED PIPE IS
 NOT ALLOWED UNDER GROUND. PE IS NOT ALLOWED WITHIN THE
 BUILDING EITHER (G2415.17.1). PLEASE RECONFIGURE THE
 METHOD AND PIPING MATERIAL FOR TWH1.
  
 2. 2020 FRC G2415.14/G2415.14.1 - PIPING BENEATH
 BUILDINGS IS PROHIBITED UNLESS IT IS ENCASED IN CONDUIT
 IN ACCORDANCE WITH THIS SECTION. PLEASE DETAIL THE
 SLEEVE TO SHOW COMPLIANCE WITH G2415.14.1 SINCE ONE END
 TERMINATES OUTDOORS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-08-30 Cont ID  
Sent By rwbrown Date 2022-08-11 Time 07:32 Rev Time 0.00
Received By rwbrown Date 2022-08-11 Time 07:31 Sent To  
Notes
2022-08-11 07:44:371ST GAS REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC G2415.11.2 - THE UNDERGROUND GAS PIPING
 CANNOT BE SCH 40 METALLIC PIPE. PLEASE DETAIL AN
 APPROVED GAS PIPING FOR ALL UNDERGROUND SECTIONS.
  
 2. 2020 FRC G2415.17.1 - PLASTIC PIPE (P.E) IS NOT
 ALLOWED WITHIN OR UNDER ANY BUILDING. YOUR ROUTING
 APPEARS TO CONFLICT WITH THAT CODE. PLEASE CLARIFY THE
 ROUTING.
  
 3. ACCORDING TO THE INDICATED INLET PRESSURE AND
 PRESSURE DROP, YOU WOULD BE USING TABLE 402.4(2). WITH
 A LONGEST RUN OF 260' AND A TOTAL LOAD OF 958,000 BTU,
 YOU APPEAR TO BE UNDERSIZED. ACCORDING TO THE LONGEST
 RUN METHOD, YOU WOULD NEED 2 1/2" ON THE 1ST PIECE OF
 PIPING. PLEASE CLARIFY THE GAS PRESSURE, AND RESUBMIT
 THE SIZING.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-05-04 Cont ID  
Sent By fmittner Date 2022-05-04 Time 15:51 Rev Time 0.00
Received By fmittner Date 2022-05-04 Time 15:51 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-10-17 Cont ID  
Sent By aoliver Date 2022-10-17 Time 07:27 Rev Time 0.00
Received By aoliver Date 2022-10-14 Time 09:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-10-12 Cont ID  
Sent By rwbrown Date 2022-10-12 Time 13:50 Rev Time 0.00
Received By rwbrown Date 2022-10-12 Time 06:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 16:24 Rev Time 0.00
Received By rmcphers Date 2022-10-05 Time 06:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-09-15 Cont ID  
Sent By mpeterso Date 2022-09-15 Time 15:50 Rev Time 0.00
Received By mpeterso Date 2022-08-30 Time 07:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-29 Cont ID  
Sent By dbattles Date 2022-08-29 Time 09:28 Rev Time 0.00
Received By dbattles Date 2022-08-09 Time 16:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-12 Cont ID  
Sent By shill Date 2022-07-12 Time 11:19 Rev Time 0.00
Received By shill Date 2022-04-27 Time 07:54 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-10-24 Cont ID  
Sent By lmarchan Date 2022-10-24 Time 16:06 Rev Time 0.00
Received By lmarchan Date 2022-10-14 Time 09:17 Sent To  
Notes
2022-10-24 16:06:03RECEIPT MU-2022-047983 - $22.46 PAID
2022-10-14 09:17:2410/14/22 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-07-07 Cont ID  
Sent By rmcphers Date 2022-07-07 Time 10:47 Rev Time 0.00
Received By rmcphers Date 2022-07-07 Time 10:47 Sent To  
Notes
2022-07-07 10:47:47PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-09-02 Cont ID  
Sent By medwards Date 2022-09-02 Time 08:46 Rev Time 0.00
Received By medwards Date 2022-09-02 Time 08:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-08-15 Cont ID  
Sent By medwards Date 2022-08-15 Time 16:13 Rev Time 0.00
Received By medwards Date 2022-08-15 Time 16:13 Sent To  
Notes
2022-08-15 16:13:57THE FOLLOWING COMMENTS ARE FROM THE 1ST REVIEW CYCLE
 AND STILL NEED TO BE ADDRESSED:
  
 1) THE DOCUMENTS IN THE SUPPORTING DOCUMENTS FOLDER
 LABELED ENERGY CALCULATIONS ARE NOT ENERGY
 CALCULATIONS, THEY ARE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. RELABEL THIS DOCUMENT AND PROVIDE THE
 ENERGY CALCULATIONS. FEC 101.5.1.1.2 THE ENERGY
 CALCULATIONS STILL HAVE NOT BEEN SUBMITTED.
  
 2) IT APPEARS THAT AHU-4 IS SUPPLY AIR TO THE GARAGE
 AND THE LIVING SPACE. THIS CANNOT HAPPEN SO PLEASE
 CORRECT THE DESIGN. FRC M1601.6
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-05-11 Cont ID  
Sent By medwards Date 2022-05-11 Time 10:34 Rev Time 0.00
Received By medwards Date 2022-05-11 Time 08:24 Sent To  
Notes
2022-05-11 10:34:401ST REVIEW FMC
 PERMIT: 22040542
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. I SPOKE TO THE MECHANICAL
 ENGINEER, HE WAS DRIVING AND COULDN?T TALK AND SAID HE
 WOULD CALL BACK IN 10 MINUTES. I DID NOT HEAR BACK. MY
 COMMENTS ARE LISTED BELOW:
  
 1) THE DOCUMENTS IN THE SUPPORTING DOCUMENTS FOLDER
 LABELED ENERGY CALCULATIONS ARE NOT ENERGY
 CALCULATIONS, THEY ARE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. RELABEL THIS DOCUMENT AND PROVIDE THE
 ENERGY CALCULATIONS. FEC 101.5.1.1.2
  
 2) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS FOR THE
 LOGGIA INDICATES A TOTAL CONDITIONED AREA OF 566 SQ.
 FT., SHEET A-003 INDICATES A TOTAL CONDITIONED SQ. FT.
 OF 628. PLEASE BE CONSISTENT. FBC 107.2.1
  
 3) THE MECHANICAL PLANS ARE NOT CLEAR AS TO THE
 LOCATION OF AHU-1 AND AHU-4. THEY BOTH ARE SHOWN ON THE
 FIRST AND SECOND FLOOR DRAWINGS. IS AHU-1 HUNG BELOW
 THE CEILING IN THE GARAGE? IS AHU-4 IN THE 2ND STORY
 ATTIC AREA THE SYSTEM BEING DUCTED TO THE GALLERY,
 BEDROOM AND THE FIRST FLOOR GARAGE? FBC 107.2.1
  
 4) AHU-1 THE RETURN IS BEING TAKEN FROM THE MASTER
 CLOSET. REMOVE FROM THE CLOSET AS IT CANNOT BE LOCATED
 IN A CLOSET. FRC M1602.2
  
 5) SHEET M-101: AHU-5: THERE IS A 4X12 SUPPLY GRILLE IN
 THE BATHROOM BUT NO DUCT SHOWN FOR THE SUPPLY. SHOW THE
 DUCTWORK FOR THIS GRILLE. FBC 107.2.1
  
 6) SHEET M-102: AHU-6: REMOVE THE RETURN AIR GRILLE
 FROM THE GUEST ROOM #2 WIC. FRC M1602.2
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 16:22 Rev Time 0.00
Received By rmcphers Date 2022-10-07 Time 16:22 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2022-09-07 Cont ID  
Sent By rmcphers Date 2022-09-07 Time 15:42 Rev Time 0.00
Received By rmcphers Date 2022-09-07 Time 15:42 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status P Date 2022-07-07 Cont ID  
Sent By rmcphers Date 2022-07-07 Time 10:43 Rev Time 0.00
Received By rmcphers Date 2022-07-07 Time 10:43 Sent To  
Notes
2022-07-07 10:47:14AE 7
 PROPOSED LOWEST FLOOR = 9.33 NAVD
 PROPOSED ATTACHED GARAGE = 9.00 NAVD

Review Stop P PLUMBING
Rev No 6 Status P Date 2022-10-14 Cont ID  
Sent By rwbrown Date 2022-10-14 Time 12:00 Rev Time 0.00
Received By rwbrown Date 2022-10-14 Time 12:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2022-10-12 Cont ID  
Sent By rwbrown Date 2022-10-12 Time 13:20 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-10-07 Cont ID  
Sent By rwbrown Date 2022-10-07 Time 10:45 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-08-30 Cont ID  
Sent By rwbrown Date 2022-08-30 Time 16:36 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
2022-08-30 16:37:543RD PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
 2. DONE
  
 3. DONE
  
 4. CHANGES DO NOT COMPLY WITH THE CODE. THE BAR SINK
 MUST DISCHARGE DOWNSTREAM OF THE WET VENT SYSTEM. --
 2020 FRC P3108.1 - THE BAR SINK IS NOT ALLOWED TO WET
 VENT THE WATER CLOSET. ONLY BATHROOM GROUP FIXTURES ARE
 ALLOWED TO BE USED AS WET VENTING FIXTURES FOR OTHER
 BATHROOM GROUP FIXTURES. THE BAR SINK MUST DISCHARGE
 DOWNSTREAM OF THE WET VENTED SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-08-11 Cont ID  
Sent By rwbrown Date 2022-08-11 Time 07:29 Rev Time 0.00
Received By rwbrown Date 2022-08-11 Time 07:29 Sent To  
Notes
2022-08-11 07:31:402ND PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
 2. 2020 FRC P3108.1 - THE SHOWER IN THE MASTER BATH -
 TWO TRAPS ARE NOT ALLOWED ON THE HIGH SIDE OF THE VENT
 CONNECTION. PLEASE RECONFIGURE SO THAT ONLY ONE TRAP IS
 UPSTREAM OF THE VENT CONNECTION.
  
 3. DONE
  
 4. NOT ADDRESSED -- 2020 FRC P3108.1 - THE BAR SINK IS
 NOT ALLOWED TO WET VENT THE WATER CLOSET. ONLY BATHROOM
 GROUP FIXTURES ARE ALLOWED TO BE USED AS WET VENTING
 FIXTURES FOR OTHER BATHROOM GROUP FIXTURES. THE BAR
 SINK MUST DISCHARGE DOWNSTREAM OF THE WET VENTED
 SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-04-28 Cont ID  
Sent By rwbrown Date 2022-04-28 Time 15:42 Rev Time 0.00
Received By rwbrown Date 2022-04-28 Time 15:25 Sent To  
Notes
2022-04-28 15:42:351ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - YOU'VE DETAILED A GAS
 WATER HEATER BUT I DO NOT SEE A GAS DIAGRAM. EITHER
 SUPPLY A GAS DIAGRAM AND A GAS SUB PERMIT FOR THIS
 MASTER PERMIT OR HAVE A SEPERATE GAS PERMIT IN PLACE TO
 SATISFY THIS COMMENT.
  
 2. 2020 FRC P3108.1 - THE MASTER BATH SHOWER SHOWS A
 VENT ON P-100 AND NOT ON P-200. PLEASE MAKE THEM MATCH.
 ALSO, BOTH TRAPS ARE NOT ALLOWED ON THE HIGH SIDE OF
 THE VENT CONNECTION. PLEASE RECONFIGURE SO THAT ONLY
 ONE TRAP IS UPSTREAM OF THE VENT CONNECTION.
  
 3. 2020 FRC P3108.1 - THE LAVATORIES IN THE BATHROOM
 NEAR THE CLOTHES WASHER HAS TWO TRAPS UPSTREAM OF THE
 VENT CONNECTION. ONLY ONE TRAP IS ALLOWED UPSTREAM OF
 THE VENT CONNECTION.
  
 4. 2020 FRC P3108.1 - THE BAR SINK IS NOT ALLOWED TO
 WET VENT THE WATER CLOSET. ONLY BATHROOM GROUP FIXTURES
 ARE ALLOWED TO BE USED AS WET VENTING FIXTURES FOR
 OTHER BATHROOM GROUP FIXTURES. THE BAR SINK MUST
 DISCHARGE DOWNSTREAM OF THE WET VENTED SYSTEM.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-08-29 Cont ID  
Sent By dbattles Date 2022-08-29 Time 09:28 Rev Time 0.00
Received By dbattles Date 2022-08-29 Time 09:21 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-08-18 Cont ID  
Sent By rmcphers Date 2022-08-18 Time 10:34 Rev Time 0.00
Received By rmcphers Date 2022-08-18 Time 10:34 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-07-07 Cont ID  
Sent By rmcphers Date 2022-07-07 Time 10:48 Rev Time 0.00
Received By rmcphers Date 2022-07-07 Time 10:48 Sent To  
Notes
2022-07-07 10:48:27SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2022-10-14 Cont ID  
Sent By rwbrown Date 2022-10-14 Time 12:03 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-10-12 Cont ID  
Sent By rwbrown Date 2022-10-12 Time 13:49 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-10-07 Cont ID  
Sent By rmcphers Date 2022-10-07 Time 16:22 Rev Time 0.00
Received By rmcphers Date 2022-10-07 Time 16:22 Sent To  
Notes
2022-10-07 10:46:24PLUMBING PAGES OKAY
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-09-07 Cont ID  
Sent By rmcphers Date 2022-09-07 Time 15:43 Rev Time 0.00
Received By rmcphers Date 2022-09-07 Time 15:43 Sent To  
Notes
2022-09-07 15:44:08SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) ELEVATION CERTIFICATE DOES NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-08-15 Cont ID  
Sent By medwards Date 2022-08-15 Time 16:19 Rev Time 0.00
Received By medwards Date 2022-08-15 Time 16:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-24 Cont ID  
Sent By mpeterso Date 2022-05-24 Time 10:19 Rev Time 0.00
Received By mpeterso Date 2022-05-24 Time 10:19 Sent To  
Notes
2022-05-11 10:35:35DIGITAL SIGNATURES FOR MECHANICAL DOCUMENTS APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-09-01 Cont ID  
Sent By fmittner Date 2022-09-01 Time 15:32 Rev Time 0.00
Received By fmittner Date 2022-09-01 Time 15:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-08-25 Cont ID  
Sent By fmittner Date 2022-08-25 Time 09:08 Rev Time 0.00
Received By fmittner Date 2022-08-25 Time 09:08 Sent To  
Notes
2022-08-25 09:09:26REQUIRES SEPEARATE LANDSCAPE PERMIT

Review Stop Z ZONING
Rev No 1 Status P Date 2022-05-04 Cont ID  
Sent By fmittner Date 2022-05-04 Time 15:51 Rev Time 0.00
Received By fmittner Date 2022-05-04 Time 15:51 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy