Plan Review Details - Permit 22040424
| Plan Review Stops For Permit 22040424 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-21 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-10-21 |
Time |
14:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2022-09-06 09:34:07 | PLAN REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT COPIES OF THE ACTUAL TEST REPORTS FOR THE | | | FLAME SPREAD AND SMOKE DEVELOPED FOR THE GENIEMAT | | | FLOORING SOUND INSULATION. I HAVE NO RECORD ON FILE OF | | | THE ACTUAL FLAME SPREAD TEST REPORT FOR THIS PRODUCT. | | | FBC 603.1 FLAME SPREAD - ASTM E 84-09 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2022-06-03 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2022-06-03 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2022-06-03 12:17:35 | 22040424 200 ARKONA CT. | | | | | | COMMENT 1: RESPONSE TO ASTM E-84 IS DENIED. LETTER IS | | | DENIED AS IT DOES NOT ADDRESS FBC 603.1. THE LETTER IS | | | SPECIFIC TO FBC 804. | | | | | | THE PROPOSED FLOOR FINISH AS STATED IN THE ICC LETTER | | | REFERENCED IN COMMENT 1 IS VINYL. AIRBORNE AND | | | STRUCTURE BORE SOUND TEST RESULTS RESPONSES DO NOT | | | SPECIFICALLY ADDRESS VINYL FLOOR FINISH. ALSO THE | | | REPORT STATES IT DOES NOT CONSTITUTE CERTIFICATION OF | | | THIS PRODUCT ETC. YOU WILL NEED TO PROVIDE A SIGNED AND | | | SEALED LETTER FROM A DESIGN PROFESSIONAL ALONG WITH THE | | | REPORT STATING WHETHER OR NOT TEST RESULTS MEET FBC | | | 1207.2 AND 1207.3. | | | | | | JIM BAKER | | | 561-805-6710 | | | [email protected] | | | | | | PREFERRED METHOD OF COMMUNICATION IS EMAIL | | | | | | A COMMENT/RESPONSE LETTER WILL PROVIDE A MORE | | | EXPEDITIOUS REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-05-12 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-05-12 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2022-05-12 09:45:47 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT COPIES OF THE ACTUAL TEST REPORTS FOR THE | | | SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE | | | DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS. | | | | | | FBC 603.1 FLAME SPREAD - ASTM E 84-09 | | | | | | FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-10-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-10-21 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-09-14 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-09-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-09-06 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-14 |
Time |
08:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2022-06-03 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2022-05-25 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-05-12 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-04-11 |
Time |
05:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-05-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-05-12 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-05-12 |
Time |
09:22 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |