Plan Review Details - Permit 22040413
Plan Review Stops For Permit 22040413
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-06-29 Cont ID  
Sent By rmcphers Date 2023-06-29 Time 08:53 Rev Time 0.00
Received By rmcphers Date 2023-06-29 Time 08:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-26 Cont ID  
Sent By rmcphers Date 2022-10-26 Time 10:34 Rev Time 0.00
Received By rmcphers Date 2022-10-26 Time 10:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 14:35 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 14:35 Sent To  
Notes
2022-05-12 14:35:57VEHICLE CHARGING STATIONS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE ACCESSIBLE CHARGING STATION - AT
 LEAST 1 CHARGING STATION PARKING SPACE NEEDS TO BE
 MARKED FOR ACCESSIBILITY - AS AN ACCESSIBLE PARKING
 SPACE ONLY - PER FBC 502

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-07-06 Cont ID  
Sent By mpeterso Date 2023-07-06 Time 16:32 Rev Time 0.00
Received By mpeterso Date 2023-07-06 Time 16:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-11-03 Cont ID  
Sent By mpeterso Date 2022-11-03 Time 14:15 Rev Time 0.00
Received By mpeterso Date 2022-11-03 Time 13:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-05-27 Cont ID  
Sent By mpeterso Date 2022-05-27 Time 12:17 Rev Time 0.00
Received By mpeterso Date 2022-05-27 Time 12:17 Sent To  
Notes
2022-05-16 08:51:37ELECTRIC REVIEW FAILED
 1) 300MCM CONDUCTORS FEEDING NBDC180 DISPENSERS MAXIMUM
 ALLOWABLE OVERCURRENT PROTECTION IS 300-AMPS. PLEASE
 DETAIL CONDUCTORS WITH SUFFICIENT AMPACITY FEEDING
 NBDC180 DISPENSERS THAT ALLOW FOR 350 AMP OVERCURRENT
 PROTECTION OR REDUCE OVERCURRENT PROTECTION SIZE TO 300
 AMP.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-06-28 Time 18:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-14 Cont ID  
Sent By lmarchan Date 2022-12-14 Time 15:02 Rev Time 0.00
Received By lmarchan Date 2022-10-18 Time 07:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-10-17 Cont ID  
Sent By lmarchan Date 2022-10-17 Time 17:07 Rev Time 0.00
Received By lmarchan Date 2022-05-03 Time 10:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-06-29 Cont ID  
Sent By rmcphers Date 2023-06-29 Time 08:57 Rev Time 0.00
Received By rmcphers Date 2023-06-29 Time 08:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-10-26 Cont ID  
Sent By rmcphers Date 2022-10-26 Time 10:34 Rev Time 0.00
Received By rmcphers Date 2022-10-26 Time 10:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 14:37 Rev Time 0.00
Received By rmcphers Date 2022-05-12 Time 14:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-12-14 Cont ID  
Sent By eschneid Date 2022-12-14 Time 12:07 Rev Time 0.75
Received By eschneid Date 2022-12-13 Time 14:22 Sent To  
Notes
2023-05-09 10:22:58FAILED
  
 1) THE COMMENTS LISTED BELOW MUST BE CORRECTED NOT ONLY
 ON THE BUILDING PERMIT, BUT ALSO AS PART OF THE MINOR
 PLANNED DEVELOPMENT AMENDMENT THAT HAS BEEN SUBMITTED
 TO THE PLANNING DIVISION.
  
 2) THERE IS A DISCREPANCY BETWEEN WHAT IS SHOWN ON THE
 DIMENSION SITE PLAN AND THE SURVEY. THE SURVEY SHOWS A
 TOTAL OF 60 FEET BETWEEN THE EXTERIOR PARKING GARAGE
 WALL COLUMNS AND THE INTERIOR GARAGE COLUMNS. THE
 60-FOOT WIDTH IS THE MINIMUM NECESSARY TO PROVIDE TWO
 18-FOOT DEEP PARKING STALLS AND THE 24-FOOT WIDE DRIVE
 AISLE MEETING CODE REQUIREMENTS. THE DIMENSION SITE
 PLAN SHOWS THE NEW EV CHARGING UNITS AND SIGNS LOCATED
 APPROXIMATELY 1-FOOT INSIDE OF THE EXTERIOR WALL,
 RESULTING IN THERE BEING EITHER INSUFFICIENT DEPTH OF
 THE EV SPACES OR A REDUCTION IN THE REQUIRED DRIVE
 AISLE WIDTH. PROVIDE A FULL DIMENSIONED CROSS SECTION
 FROM THE EXTERIOR TO THE CENTER OF THE GARAGE SHOWING
 ACCURATE DIMENSIONS FOR THE SPACES ON BOTH SIDES OF THE
 DRIVE AISLE AND THE DRIVE AISLE THAT MEET CODE. PROVIDE
 A DIMENSIONED DRAWING OF THE EV CHARGING UNIT THAT
 INCLUDES THE DEPTH OF THE UNIT IN PLAN AND ELEVATION.
 THE EV CHARGING UNIT DIMENSION AND SIGN LOCATION SHALL
 BE ACCURATELY SHOWN ON THE DIMENSIONED SITE PLAN. NOTE:
 IT APPEARS THAT THE DEPTH OF THE EV CHARGING UNIT AND
 SIGN IS LESS THAN THE DEPTH OF THE EXTERIOR COLUMN, SO
 THE FACE OF THE UNIT AND THE SIGN COULD BE MOVED
 BETWEEN THE COLUMNS AND STILL MEET THE MINIMUM DEPTH
 ACROSS THE PARKING GARAGE.
  
 3) SHOW THE FULL ACCESSIBLE ROUTE FROM THE ACCESS AISLE
 TO THE EXIT FROM THE GARAGE. PLEASE NOTE THAT THE ROUTE
 IS NOT PERMITTED TO DIRECT THE ADA USER BEHIND A PARKED
 VEHICLE THAT IS NOT THEIR OWN.
  
 CONTACT ERIC SCHNEIDER @ 561-822-1446
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-06-10 Cont ID  
Sent By eschneid Date 2022-06-10 Time 17:15 Rev Time 0.50
Received By eschneid Date 2022-06-10 Time 15:48 Sent To  
Notes
2022-06-10 17:15:01FAILED
  
 1) A MINOR PLANNED DEVELOPMENT AMENDMENT IS REQUIRED
 FOR CHANGES BASED ON THE INSTALLATION OF THE EV
 FACILITIES. THIS MAY BE INCLUDED WITH THE OPEN MINOR
 PLANNED DEVELOPMENT AMENDMENT THAT IS UNDER REVIEW FOR
 THE 530 HIBISCUS GARAGE.
  
 2) THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS
 REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A
 LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES
 THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT.
  
 3) THE CITYPLACE DEVELOPMENT OF REGIONAL IMPACT, WHICH
 INCLUDES ROSEMARY SQUARE, REQUIRES THAT MECHANICAL
 EQUIPMENT, TO INCLUDE TRANSFORMERS, IS SCREENED FROM
 PUBLIC VIEW. THE CURRENT PLAN SHOWS NO SCREENING, WHICH
 IS NOT PERMITTED.
  
 4) THE PARKING SPACE STRIPING MUST CONFORM TO CITY
 STANDARDS, WHICH REQUIRE WHITE 4 INCH, NOT GREEN
 STRIPES. THE ELECTRIC VEHICLE NOTE MAY BE IN GREEN.
  
 5) THE DIMENSION SITE PLAN SHOWS THE DEPTH OF THE EV
 SPACES AS LESS THAN 18 FEET, WHICH IS NOT PERMITTED.
 ALL SPACES ARE REQUIRED TO HAVE 18 FEET IN CLEAR DEPTH.
 THIS REQUIRES THE EV CHARGERS AND SIGNS TO BE MOVED
 FURTHER TO THE EAST.
  
 6) PROVIDE A PARKING SPACE DETAIL.
  
 7) THE ADA ACCESS AISLE IS REQUIRED TO BE WHITE
 REGARDLESS OF THE SURFACE ON WHICH IT IS PAINTED.
  
 8) SHOW THE FULL ACCESSIBLE ROUTE FROM THE ACCESS AISLE
 TO THE EXIT FROM THE GARAGE. PLEASE NOTE THAT THE ROUTE
 IS NOT PERMITTED TO DIRECT THE ADA USER BEHIND A PARKED
 VEHICLE THAT IS NOT THEIR OWN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  