Plan Review Details - Permit 22040388
Plan Review Stops For Permit 22040388
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-05-10 Cont ID  
Sent By cpuell Date 2022-05-10 Time 12:56 Rev Time 0.00
Received By cpuell Date 2022-05-10 Time 12:56 Sent To  
Notes
2022-05-10 12:56:52ADDRESS APPROPRIATE FOR PROJECT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-08-26 Cont ID  
Sent By mpeterso Date 2022-08-26 Time 09:56 Rev Time 0.00
Received By mpeterso Date 2022-08-26 Time 09:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-16 Cont ID  
Sent By mpeterso Date 2022-05-16 Time 13:31 Rev Time 0.00
Received By mpeterso Date 2022-05-16 Time 13:31 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-08-03 Cont ID  
Sent By shill Date 2022-08-03 Time 13:54 Rev Time 0.00
Received By shill Date 2022-08-03 Time 13:54 Sent To  
Notes
2022-08-03 13:55:44PROVISO - OBTAIN A ROW PERMIT IF REQUIRED
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-27 Cont ID  
Sent By mpeterso Date 2023-01-27 Time 13:47 Rev Time 0.00
Received By mpeterso Date 2022-08-12 Time 12:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-03 Cont ID  
Sent By shill Date 2022-08-03 Time 13:55 Rev Time 0.00
Received By shill Date 2022-05-10 Time 05:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-01-27 Cont ID  
Sent By mpeterso Date 2023-01-27 Time 13:45 Rev Time 0.00
Received By mpeterso Date 2023-01-27 Time 13:44 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2023-01-25 Cont ID  
Sent By ckimmerl Date 2023-01-25 Time 10:06 Rev Time 0.00
Received By ckimmerl Date 2023-01-25 Time 10:04 Sent To  
Notes
2023-01-25 10:05:171. THE SUBMITTED COMMUNICATION FACILITY PLACEMENT
 PERMIT - CITY RIGHTS-OF-WAY MUST BE APPROVED PRIOR TO
 THIS PERMIT BEING APPROVED. THE PLANS INCLUDED WITH
 THIS ELECTRICAL PERMIT MUST MATCH THE PLANS APPROVED
 WITH THE AFOREMENTIONED PERMIT.
  
 2. PROPOSED WCF POLE LOCATION, STEALTH DESIGN, COLOR,
 AND DETAILS MEET CITY ZONING STANDARDS.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 [email protected] 822-1426
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-06-22 Cont ID  
Sent By ckimmerl Date 2022-06-22 Time 16:13 Rev Time 0.00
Received By ckimmerl Date 2022-06-22 Time 16:12 Sent To  
Notes
2022-06-22 16:12:536.22.22 REVIEW COMMENTS - 22040388 ? WCF ELECTRIC FOR
 POLE
  
 1. THE SUBMITTED COMMUNICATION FACILITY PLACEMENT
 PERMIT - CITY RIGHTS-OF-WAY MUST BE APPROVED PRIOR TO
 THIS PERMIT BEING APPROVED. THE PLANS INCLUDED WITH
 THIS ELECTRICAL PERMIT MUST MATCH THE PLANS APPROVED
 WITH THE AFOREMENTIONED PERMIT. SOME OF THE COMMENTS
 BELOW ARE INCLUDED ON THE PLACEMENT PERMIT REVIEW AS
 WELL AS WITH THIS PERMIT.
  
 2. PLEASE PROVIDE A MORE LEGIBLE/CLEAR SURVEY, THE
 DETAILS OF THE DOCUMENT ARE BLURRED/FRAGMENTED
  
 3. THE POLE?S FOUNDATION DIMENSION (SHEET C-3) SHOWN AT
 2FT.-6IN., THIS MAY BE ENCROACHING INTO PRIVATE
 PROPERTY. PLEASE PROVIDE SEPARATION DISTANCE/DIMENSION
 OF POLE FROM ROW LINE, ADJUST POLE LOCATION TO BE
 OUTSIDE OF PRIVATE PROPERTY IF NECESSARY.
  
 4. POLE POWER ROUTE, HANDHOLES, BOREPITS, AND DEPTH
 APPEARS TO MEET STANDARDS.
  
  
  
  
  
 1.5.22 REVIEW COMMENTS - WCF POLE LOCATION PERMIT ?
 21120280
  
 PROPOSED POLE LOCATION IS SUBJECT TO SPECIAL EVENTS
 REVIEW. ALL COMMENTS BELOW ARE PENDING THE LOCATION
 APPROVAL FROM SPECIAL EVENTS.
  
 1. PROPOSED POWER ROUTE, BORE PIT, AND UNDERGROUND
 ELECTRICAL CONNECTION IS SHOWN TO POTENTIALLY CONFLICT
 WITH EXISTING GAS LINE, SEWER, AND WATER, PLEASE
 PROVIDE THE NECESSARY UTILITY LETTERS GRANTING APPROVAL
 OF THIS ELECTRICAL CONNECTION LOCATION AND DEPTH.
  
 2. PROPOSED BORE PITS AND HANDHOLE ARE TOO CLOSE TO
 EXISTING PALM TREES, PLEASE ADJUST TO PROVIDE THE
 NECESSARY SPACING TO PROTECT ROOT/TREE VIABILITY.
 RECOMMENDED AT LEAST 8 FT. CLEARANCE FROM PALMS TO
 SAFELY PROVIDE A BUFFER TO THE ROOT SYSTEM.
  
 3. PLEASE PROVIDE A TYPICAL CROSS-SECTION SHOWING THE
 DEPTH OF THE UNDERGROUND ELECTRICAL COMPONENTS.
  
 4. PROPOSED LOCATION IS SUBJECT TO SPECIAL EVENTS
 APPROVAL.
  
 5. THE POLE STEALTH DESIGN MEETS CITY STANDARDS.
  
  
  
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER ? 822.1426 ? [email protected]
  