Plan Review Details - Permit 22040174
Plan Review Stops For Permit 22040174
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-06-10 Cont ID  
Sent By pvalenti Date 2022-06-10 Time 15:05 Rev Time 0.00
Received By pvalenti Date 2022-06-10 Time 15:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-02 Cont ID  
Sent By jbrooks Date 2022-06-02 Time 10:00 Rev Time 0.00
Received By jbrooks Date 2022-06-02 Time 10:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By jbrooks Date 2022-04-12 Time 11:12 Rev Time 0.00
Received By jbrooks Date 2022-04-12 Time 07:49 Sent To  
Notes
2022-04-12 11:12:42JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND
 SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR
 PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL
 LIMITATIONS #7. PLEASE NOTE THIS PROJECT IS LOCATED IN
 AN EXPOSURE C CATEGORY AREA.
 2. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH
 TESTING APPLICATION STANDARD TAS 105 AS REQUIRED BY
 RECOVER SYSTEM LIMITATIONS: #2 OF MIAMI DADE COUNTY NOA
 NO.: 20-1105.03.
 3. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE
 REPORT PREPARED BY A FLORIDA REGISTERED DESIGN
 PROFESSIONAL.
 4. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2022-04-12 Cont ID  
Sent By jbrooks Date 2022-04-12 Time 11:19 Rev Time 0.00
Received By jbrooks Date 2022-04-12 Time 11:19 Sent To  
Notes
2022-04-12 11:20:19*FLAT ROOF ONLY*

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-10 Cont ID  
Sent By pvalenti Date 2022-06-10 Time 15:10 Rev Time 0.00
Received By pvalenti Date 2022-06-10 Time 13:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-02 Cont ID  
Sent By jbrooks Date 2022-06-02 Time 10:02 Rev Time 0.00
Received By jbrooks Date 2022-05-18 Time 05:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-12 Cont ID  
Sent By jbrooks Date 2022-04-12 Time 11:20 Rev Time 0.00
Received By jbrooks Date 2022-04-11 Time 07:28 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-10 Cont ID  
Sent By pvalenti Date 2022-06-10 Time 15:05 Rev Time 0.00
Received By pvalenti Date 2022-06-10 Time 15:05 Sent To  
Notes
2022-06-10 15:10:04PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 SIGNATURE REVIEW APPROVED.
  
 THE ENGINEER'S HAND SIGNED ORIGINAL PAPER DOCUMENTS FOR
 ENHANCED FASTENING CALCULATIONS, FIELD WITHDRAWAL
 RESISTANCE TEST, AND MOISTURE REPORT HAVE BEEN
 SUBMITTED. THESE DOCUMENTS HAVE BEEN ROUTED TO STORAGE
 BIN.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-06-02 Cont ID  
Sent By jbrooks Date 2022-06-02 Time 10:01 Rev Time 0.00
Received By jbrooks Date 2022-06-02 Time 10:01 Sent To  
Notes
2022-06-02 10:02:14JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS, FIELD WITHDRAWAL RESISTANCE TEST &
 MOISTURE REPORT ARE COPIES OF WET SIGNATURES. PROVIDE
 ORIGINAL DOCUMENTS.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME,
 OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND
 SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  


Account Summary | Usage Policy | Privacy Policy