| Plan Review Stops For Permit 22031303 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-11 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-11 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-11 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-11 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2022-05-11 08:29:46 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT "THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY" | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-03 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-03 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2022-05-03 09:55:15 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-11 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-11 |
Time |
08:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-03 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-03 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2022-05-03 10:00:57 | CONDO REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVALS FOR THE NEW EXTERIOR DOORS AND | | | WINDOWS - ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND | | | MARKED APPROVED BY THE DESIGNER (ARCHITECT) OF RECORD | | | FBC WPB 107.3.4 | | | | | | 2) FOR THE FLOORING - THE FOLLOWING ACUSTICAL TEST | | | REPORTS ARE REQUIRED: | | | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | | CEILING DESCRIPTION) | | | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | | DROP CEILING DESCRIPTION) | | | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | | ATTACHED TO THE FLOORING) | | | | | | YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY | | | THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO | | | PROJECTDOX ( [email protected] ) | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-04-21 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-21 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-21 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-05-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-05-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-05-09 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-03-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-03-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-03-30 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2022-03-30 12:01:29 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET D - 1 - THERE IS ARE INDICATIONS OF "REMOVE | | | ALL FLOORING THROUGHOUT" IN THE MATER SUITE, DINING | | | AREA AND LIVING AREA. | | | | | | HOWEVER, ON SHEET A - 1 THERE ARE INDICATIONS OF " | | | EXIST. FLOOR TO REMAIN" IN THE DINING AREA & LIVING | | | AREA AND NOTHING IN THE MASTER SUITE. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE | | | CLARIFICATIONS/CONFIRMATION OF WHAT IS ACTUALLY BEING | | | PROPOSED/COMPLETED AND CORRECT ON ALL SHEETS. | | | | | | 1A) SHEET A - 1 - THERE IS AN INDICATION WITHIN THE | | | FLOOR FINISH SCHEDULE UNDER MODEL NAME/NUMBER OF | | | "FLOORING TILE OVER PROFLEX....." | | | | | | TILE FLOORING COULD HAVE DIFFERENT MEANINGS AND IF NOT | | | CERAMIC/PORCELAIN/MARBLE/CEMENT IT CAN BE | | | VINYL/LAMINATE ETC AND IS MANUFACTURED FROM AROUND THE | | | WORLD AND NOT ALL ARE TESTED AND MEETING LISTED AND | | | NFPA STANDARDS. | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE SPECIFIC | | | TILE TYPE AND/OR PRODUCT SPEC SHEETS OF THE PROPOSED | | | FINISHED FLOORING INDICATING THE FIRE BEHAVIOR RATING | | | | | | PER NFPA 101, CH 30 | | | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH | | | SECTION 10.2. | | | | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | FLOORING/TILE IS MANUFACTURED AROUND THE WORLD AND NOT | | | ALL ARE TESTED AND MEETING LISTED AND NFPA STANDARDS. | | | | | | IF THE PROPOSED FLOORING IS PORCELAIN/CERAMIC TILE, | | | NATURAL STONE TILE, CONCRETE TILES, PRODUCT SPEC SHEETS | | | WOULD NOT BE REQUIRED. | | | | | | PRODUCT SPEC SHEETS ARE REQUIRED FOR LVT, VINYL | | | FLOORING, WOOD/VINYL LAMINATES, ETC. | | | | | | PLEASE PROVIDE THE TILE/FINISHED FLOORING PRODUCT | | | TYPE/NAME AND SPEC SHEETS IF APPLICABLE | | | . | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-06 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-03 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-29 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-04-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-11 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-11 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-04-05 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-04-05 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-11 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-11 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-11 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-03 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-03 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|