Plan Review Details - Permit 22031272
Plan Review Stops For Permit 22031272
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 15:41 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-05-25 Cont ID  
Sent By pleduc Date 2022-05-25 Time   Rev Time 0.00
Received By pleduc Date 2022-05-25 Time 11:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-05-05 Cont ID  
Sent By pleduc Date 2022-05-05 Time   Rev Time 0.00
Received By pleduc Date 2022-05-05 Time 13:50 Sent To  
Notes
2022-05-05 13:54:43THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF THE SPEC SHEET FOR THE
 FLOOR UNDERLAYMENT, BUT NO SPEC SHEET NOR A PRODUCT
 NAME FOR THE ACTUAL PROPOSED VINYL FLOORING.
  
 PER NFPA 101, CH 30 APARTMENT OCCUPANCIES
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
  
 VINYL FLOORING IS MANUFACTURED AROUND THE WORLD AND NOT
 ALL ARE TESTED AND MEETING LISTED AND NFPA STANDARDS.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE PRODUCT
 SPEC SHEETS AND THE PRODUCT NAME OF THE PROPOSED
 FINISHED
 VINYL FLOORING INDICATING THE FIRE BEHAVIOR RATING.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-25 Cont ID  
Sent By lmarchan Date 2022-05-25 Time 12:37 Rev Time 0.00
Received By lmarchan Date 2022-05-25 Time 08:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 15:42 Rev Time 0.00
Received By jwitmer Date 2022-05-04 Time 07:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 15:42 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***