Plan Review Details - Permit 22031236
Plan Review Stops For Permit 22031236
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-12-14 Cont ID  
Sent By cthroop Date 2022-12-14 Time 14:31 Rev Time 0.00
Received By cthroop Date 2022-12-14 Time 14:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-06-17 Cont ID  
Sent By cthroop Date 2022-06-17 Time 14:11 Rev Time 0.00
Received By cthroop Date 2022-06-11 Time 09:45 Sent To  
Notes
2022-06-17 14:20:11PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE ELEVATIONS FROM A LICENSED SURVEYOR TO
 DEMONSTRATE RETENTION OF RAIN WATER ON THE PROPERTY.
 INCLUDE ELEVATIONS OF ADJOINING PROPERTY.
 PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
  
 110.9 IMPACT OF CONSTRUCTION. ALL CONSTRUCTION ACTIVITY
 REGULATED BY THIS CODE SHALL BE PERFORMED IN A MANNER
 SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF ADJACENT
 PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT
 SAID PROPERTY PURSUANT TO A CONSENT GRANTED BY THE
 APPLICABLE PROPERTY OWNER, UNDER TERMS OR CONDITIONS
 AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS
 INCLUDES, BUT IS NOT LIMITED TO, THE CONTROL OF DUST,
 NOISE, WATER OR DRAINAGE RUN-OFFS, DEBRIS, AND THE
 STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION
 ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC
 SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT
 PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN
 COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE
 POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES.
 ACCORDINGLY, DEVELOPERS, CONTRACTORS AND OWNERS OF ALL
 NEW RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS,
 POOLS, PATIOS, DRIVEWAYS, DECKS OR SIMILAR ITEMS, ON
 EXISTING PROPERTIES RESULTING IN A SIGNIFICANT DECREASE
 OF PERMEABLE LAND AREA ON ANY PARCEL OR HAS ALTERED THE
 DRAINAGE FLOW ON THE DEVELOPED PROPERTY SHALL, AS A
 PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED
 DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A
 CERTIFICATION FROM A LICENSED PROFESSIONAL SHALL BE
 SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL
 OF THE FINAL INSPECTION.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-14 Cont ID  
Sent By shill Date 2022-05-14 Time 15:06 Rev Time 0.00
Received By shill Date 2022-05-14 Time 15:06 Sent To B
Notes
2022-05-14 15:07:00****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FBC 107, REVISE PLAN TO SHOW HOW YOU WILL PREVENT
 WATER FROM DRAINING ONTO THE ADJACENT PARCELS.
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2022-06-22 Cont ID  
Sent By amhamilt Date 2022-06-22 Time 10:52 Rev Time 0.00
Received By amhamilt Date 2022-06-22 Time 10:52 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2022-05-24 Cont ID  
Sent By amhamilt Date 2022-05-24 Time 14:50 Rev Time 0.00
Received By amhamilt Date 2022-05-24 Time 14:50 Sent To  
Notes
2022-05-24 14:53:22THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PROPERTY IS IN A HISTORIC DISTRICT, PLANS INDICATE
 VINYL FENCING. VINYL IS NOT AN APPROVED MATERIAL TYPE
 FOR FENCING, PLEASE REVISE TO EITHER WOOD OR COMPOSITE
 FENCING. FENCE SHOULD ALSO BE APPLIED FOR UNDER
 SEPARATE PERMIT.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-14 Cont ID  
Sent By cthroop Date 2022-12-14 Time 14:31 Rev Time 0.00
Received By cthroop Date 2022-11-22 Time 10:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-23 Cont ID  
Sent By aoliver Date 2022-06-23 Time 10:05 Rev Time 0.00
Received By aoliver Date 2022-06-06 Time 08:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-25 Cont ID  
Sent By shill Date 2022-05-25 Time 08:03 Rev Time 0.00
Received By lmarchan Date 2022-03-25 Time 06:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-11 Cont ID  
Sent By shill Date 2022-06-11 Time 09:45 Rev Time 0.00
Received By shill Date 2022-06-11 Time 09:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-14 Cont ID  
Sent By shill Date 2022-05-14 Time 15:07 Rev Time 0.00
Received By shill Date 2022-05-14 Time 15:07 Sent To SIGNATURE
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-12-13 Cont ID  
Sent By ajones Date 2022-12-13 Time 16:30 Rev Time 0.00
Received By ajones Date 2022-12-13 Time 16:30 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-06-10 Cont ID  
Sent By afowlkes Date 2022-06-10 Time 10:53 Rev Time 0.00
Received By afowlkes Date 2022-06-10 Time 10:48 Sent To  
Notes
2022-06-10 10:53:4506/10/22 FAILED - SCOPE OF WORK IS STILL NOT PROVIDED.
 THE PROVIDED SITE PLAN SHOWS IMPROVEMENTS THAT NEED TO
 BE COVERED UNDER SEPERATE PERMITS. AT A MINIMUM, A
 DRIVEWAY AND FENCE PERMIT WOULD BE NEEDED AS WELL. FOR
 FUTURE RESUBMITALS, TAKE OUT MENTION OF ALL WORK
 COVERED UNDER SEPERATE PERMITS (THE FENCE, LANDSCAPING
 ETC) AND SUBMIT A SITE PLAN OUTLINING THE CHANGES
 COVERED UNDER THIS PERMIT ONLY.
  
 ALEXANDER FOWLKES
 5618221431
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-04-04 Cont ID  
Sent By afowlkes Date 2022-04-04 Time 13:26 Rev Time 0.00
Received By afowlkes Date 2022-04-04 Time 13:26 Sent To  
Notes
2022-04-04 13:28:4304/04/2022 FAILED - DOCUMENTS DO NOT CLEARLY DEFINE
 WHAT WORK IS BEING COVERED UNDER THE PERMIT. NEED TO
 PROVIDE A SCOPE OF WORK
  
 ALEXANDER FOWLKES
 5618221431
 [email protected]


Account Summary | Usage Policy | Privacy Policy