| Plan Review Stops For Permit 22031125 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-03-31 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-03-31 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-03-31 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2022-03-31 12:04:35 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-21 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-21 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-25 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-24 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2022-05-25 10:19:47 | NEW SFR | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE LOW | | | SLOPE ROOFING - REVIEWED AND MARKED APPROVED BY THE | | | DESIGNER OF RECORD FBC WPB 107.3.4 | | | | | | 2) PLEASE SHOW THE SLOPE FOR THE REAR LOW SLOPE ROOF | | | DECK FBC R905 | | | | | | 3) PLEASE SHOW THE ATTIC ACCESS LOCATION AND OPENING | | | SIZE - R807.1 | | | | | | 4) PLEASE SHOW THE FLOOR TRUSS DRAFT STOPPING LOCATION | | | AND TYPE PER FBC R302.12 | | | | | | 5) PLEASE SHOW THE GARAGE CEILING DRYWALL THICKNESS AND | | | TYPE TO COMPLY WITH FBC TABLE R302.6 FROM HABITABLE | | | ROOMS ABOVE THE GARAGE. NOT LESS THAN 5/8-INCH TYPE X | | | GYPSUM BOARD OR EQUIVALENT | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-29 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-29 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-06 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-06 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2022-06-06 10:17:51 | PREVIOUS COMMENT NOT ADDRESSED. PLAN STILL DETAILS 2/0 | | | CU CONDUCTORS FOR 200 AMP PANEL. THESE SHOULD BE | | | CORRECTLY SIZED AT 3/0 CU |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-04-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-25 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-25 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2022-04-25 11:46:41 | ELECTRIC REVIEW FAILED | | | 1) PLEASE DETAIL CORRECT SIZED 3/0 FEEDER CONDUCTOR FOR | | | 200-AMP ELECTRIC PANEL. NEC 310.15 (B)(7)(2) DOES NOT | | | APPLY AS THESE FEEDER CONDUCTORS DO NOT SUPPLY THE | | | ENTIRE LOAD OF THE DWELLING | | | 2) PLEASE DETAIL A CORRECTED LOAD CALCULATION FOR THE | | | ENTIRE ELECTRIC SERVICE INCLUDING PANELS A, B, AND POOL | | | PANEL BY CORRECTLY USING NEC 220..40 OR NEC 220.82 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-25 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-02 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2022-05-25 11:53:55 | LOW VOLTAGE REVIEW FAILED | | | 1) A LOW VOLTAGE SUB PREMIT APPLICATION WAS SUBMITTED | | | WITHOU ANY PALNS. PLEASE PROVIDE LOW VOLTAGE WIRING | | | PLAN. FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-04-06 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-04-06 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-29 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-22 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-21 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-02 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-25 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-03-31 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-27 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-21 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2022-06-27 11:07:13 | RECEIPT MU-2022-028935 - $2404.37 PAID | | 2022-06-21 15:51:49 | 6/21/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-24 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-24 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2022-05-24 16:54:15 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2022-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-14 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-14 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-04-06 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-04-06 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-04-06 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-21 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-21 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-25 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-25 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2022-05-25 10:20:34 | SEE BUILDING PLAN REVIEW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-29 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-29 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-06 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-06 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2022-06-06 10:20:20 | ALL PLANS HAVE PASSED SIGNATURE |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-05-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-05-25 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-25 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-04-07 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-04-07 |
Time |
14:57 |
Sent To |
|
|
| Notes |
|
|