Plan Review Details - Permit 22031099
Plan Review Stops For Permit 22031099
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 10:11 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 08:35 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-10 Cont ID  
Sent By ccole Date 2022-05-10 Time 12:13 Rev Time 0.00
Received By ccole Date 2022-05-10 Time 12:13 Sent To  
Notes
2022-05-10 12:39:261ST REVIEW FBC-2020 RES.
 PERMIT- 22031099
 5/10/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SUBMIT AN UP TO DATE GENERATOR PAD DETAIL
 DIGITALLY SIGNED AND SEALED BY THE ENGINEER OF RECORD-
 SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-04-14 Cont ID  
Sent By fgiaquin Date 2022-04-14 Time 22:17 Rev Time 0.00
Received By fgiaquin Date 2022-04-14 Time 22:09 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-08-17 Cont ID  
Sent By ccole Date 2022-08-17 Time 08:55 Rev Time 0.00
Received By ccole Date 2022-08-17 Time 06:57 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-08-04 Cont ID  
Sent By ccole Date 2022-08-04 Time 12:27 Rev Time 0.00
Received By ccole Date 2022-08-04 Time 11:09 Sent To  
Notes
2022-08-04 12:29:022ND REVIEW FBC-2020 RES. GAS
 PERMIT- 22031099
 8/4/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 NFPA 58
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: THE RESUBMITTED RISER SHOWS
 NON-COMPLIANCE FOR PIPE SIZING.
  
 A) THE NOTE INDICATING AN 11.0 IN.WC. SYSTEM, WHICH IS
 A LOW PRESSURE SYSTEM, IS NOT APPLICABLE TO THE
 PRESSURE OF THE SYSTEM FROM THE 1ST STAGE REGULATOR AT
 THE TANK TO THE 2ND STAGE AT THE METER. PLEASE REFER TO
 SECS. 610.1.1 & 610.2.1, AND TABLE 16.1(N) NFPA 58.
 PLEASE LABEL THE 1ST AND 2ND STAGE REGULATORS ON THE
 PLAN AND SHOW THE INPUT AND OUTPUT PRESSURES AT THE
 LOCATIONS.
  
 B) BASED ON TABLE 16.1(N) NFPA 58 THE 1/2-INCH EXISTING
 PE PIPE FROM THE 1ST STAGE TO THE 2ND STAGE AT THE
 METER IS UNDERSIZED. THE MINIMUM PIPE SIZE BASED ON THE
 TOTAL 1,329,5000 BTU LOAD IS 1-INCH. IT APPEARS THE
 EXISTING PIPE WILL HAVE TO BE INCREASED IN SIZE DUE TO
 THE INCREASED LOAD OF THE SYSTEM.
  
 C) PLEASE PROVIDE A PIPING DETAIL AT THE METER SHOWING
 THE TYPES AND SIZES OF INPUT AND OUTPUT PIPES AT THE
 METER, LOCATIONS OF TEES, AND PE RISER CONNECTIONS-
 SEC. 6.11.2.2 NFPA 58.
  
 D) PLEASE CORRECT THE 424,000 BTU LOAD SHOWN FOR THE
 GENERATOR. BASED ON THE SUBMITTED SPECS THE LOAD IS
 340,000 BTU.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE@WPB.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 10:39 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 08:36 Sent To  
Notes
2022-05-31 10:41:58 
 1ST REVIEW FBC-2020 RES. GAS
 PERMIT- 22031099
 5/31/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 NFPA 58
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: THE MOST RECENT GAS PERMIT IN THE WPB
 BUILDING DEPARTMENT RECORDS THAT SHOWED THE FULL BTU
 LOAD OF ALL GAS-FIRED APPLIANCES WAS PERMIT- 05081958.
 THE GAS ISOMETRIC ON FILE SHOWS A TOTAL BTU LOAD OF
 920,000 WHICH INCLUDED A 400,000 BTU POOL HEATER.
 PLEASE REVISE THE GAS RISER TO INCLUDE THE FOLLOWING
 INFORMATION PER NFPA 58:
 A) TOTAL BTU LOAD OF THE SYSTEM AND INDIVIDUAL
 APPLIANCE BTU LOADS. PLEASE NOTE THE GENERATOR SPECS
 SHOW A 340,000 BTU LOAD FOR THE GENERATOR.
 B) SHOW THE TANK LOCATION AND THE TOTAL DEVELOPED
 LENGTH OF THE SYSTEM FROM THE TANK TO THE MOST REMOTE
 APPLIANCE OUTLET.
 C) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 D) TYPES AND SIZES OF GAS PIPING.
 E) LOCATIONS OF REGULATORS AND THE INPUT AND OUTPUT
 PRESSURES.
 F) PIPE SIZING TABLES.
  
 2) THE GAS RISER SHALL BEAR THE PRINTED NAME, LICENSE
 NUMBER AND SIGNATURE OF THE GAS PIPING INSTALLATION
 CONTRACTER OR QUALIFIER WHO PREPARED THE DRAWING- SEC.
 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2022-08-17 Time   Rev Time 0.00
Received By lmarchan Date 2022-08-16 Time 16:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-10 Cont ID  
Sent By vbroglia Date 2022-08-10 Time 15:00 Rev Time 0.00
Received By vbroglia Date 2022-08-03 Time 06:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-31 Cont ID  
Sent By vbroglia Date 2022-05-31 Time 13:25 Rev Time 0.00
Received By vbroglia Date 2022-05-12 Time 07:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-05-10 Time   Rev Time 0.00
Received By cdecoeur Date 2022-03-24 Time 07:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status N Date 2022-08-17 Cont ID  
Sent By ccole Date 2022-08-17 Time 08:31 Rev Time 0.00
Received By ccole Date 2022-08-17 Time 06:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2022-08-04 Cont ID  
Sent By ccole Date 2022-08-04 Time 11:10 Rev Time 0.00
Received By ccole Date 2022-08-04 Time 11:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 10:11 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 08:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-08-04 Cont ID  
Sent By ccole Date 2022-08-04 Time 12:30 Rev Time 0.00
Received By ccole Date 2022-08-04 Time 12:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By ccole Date 2022-05-31 Time 10:43 Rev Time 0.00
Received By ccole Date 2022-05-31 Time 08:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-24 Cont ID  
Sent By pvalenti Date 2022-03-24 Time 14:25 Rev Time 0.00
Received By pvalenti Date 2022-03-24 Time 14:25 Sent To  
Notes
2022-03-24 14:35:52PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
  
 SIGNATURE REVIEW DENIED:
  
 THE SUBMITTALS ARE IN PROJECT DOX.
  
 THE AMERICAST GENERATOR PAD DOES NOT HAVE A THIRD PARTY
 VERIFIED DIGITAL SIGNATURE. THE PAPER SUBMITTALS HAVE A
 COPY OF THE ENGINEER'S DIGITAL SIGNATURE. PLEASE
 PROVIDE SIGNATURES AS PER THE NOTES BELOW:
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  
  

Review Stop Z ZONING
Rev No 4 Status P Date 2022-08-10 Cont ID  
Sent By vbroglia Date 2022-08-10 Time 15:00 Rev Time 0.00
Received By vbroglia Date 2022-08-10 Time 15:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2022-05-31 Cont ID  
Sent By vbroglia Date 2022-05-31 Time 13:27 Rev Time 0.00
Received By vbroglia Date 2022-05-31 Time 13:27 Sent To  
Notes
2022-05-31 13:29:325/31/2022 FAILED
  
 NEW SURVEY UPLOADED ON 5/27/2022 SHOWS GENERATOR TO BE
 5 FEET FROM PROPERTY LINES
  
 AND NEEDS TO BE 6 FEET AWAY FROM THE PROPERTY LINE TO
 COMPLY WITH THE ZONING CODE:
  
 PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR:
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET
 INTO A REQUIRED SETBACK.
  
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-05-24 Cont ID  
Sent By vbroglia Date 2022-05-24 Time 10:36 Rev Time 0.00
Received By vbroglia Date 2022-05-24 Time 10:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-04-05 Cont ID  
Sent By vbroglia Date 2022-04-05 Time 14:23 Rev Time 0.00
Received By vbroglia Date 2022-04-05 Time 14:23 Sent To  
Notes
2022-04-05 14:26:354/5/2022 FAILED
  
 PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR:
 MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET
 INTO A REQUIRED SETBACK.
  
 THE REQUIRED SETBACK FOR SF7 IS 15 FEET OR 10% OF LOT
 DEPT WHICHEVER IS LESS, THEREFORE THE REQUIRED SETBACK
 FOR THIS PROPERTY IS 10 FEET
  
 VALENTINA BROGLIA
 ASSOCIATE PLANNER
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved