| Plan Review Stops For Permit 22031099 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-10 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-10 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2022-05-10 12:39:26 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 22031099 | | | 5/10/22 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SUBMIT AN UP TO DATE GENERATOR PAD DETAIL | | | DIGITALLY SIGNED AND SEALED BY THE ENGINEER OF RECORD- | | | SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | BUILDING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-04-14 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-04-14 |
Time |
22:17 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-04-14 |
Time |
22:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-17 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-17 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-04 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-04 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2022-08-04 12:29:02 | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 22031099 | | | 8/4/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | NFPA 58 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) GAS RISER: THE RESUBMITTED RISER SHOWS | | | NON-COMPLIANCE FOR PIPE SIZING. | | | | | | A) THE NOTE INDICATING AN 11.0 IN.WC. SYSTEM, WHICH IS | | | A LOW PRESSURE SYSTEM, IS NOT APPLICABLE TO THE | | | PRESSURE OF THE SYSTEM FROM THE 1ST STAGE REGULATOR AT | | | THE TANK TO THE 2ND STAGE AT THE METER. PLEASE REFER TO | | | SECS. 610.1.1 & 610.2.1, AND TABLE 16.1(N) NFPA 58. | | | PLEASE LABEL THE 1ST AND 2ND STAGE REGULATORS ON THE | | | PLAN AND SHOW THE INPUT AND OUTPUT PRESSURES AT THE | | | LOCATIONS. | | | | | | B) BASED ON TABLE 16.1(N) NFPA 58 THE 1/2-INCH EXISTING | | | PE PIPE FROM THE 1ST STAGE TO THE 2ND STAGE AT THE | | | METER IS UNDERSIZED. THE MINIMUM PIPE SIZE BASED ON THE | | | TOTAL 1,329,5000 BTU LOAD IS 1-INCH. IT APPEARS THE | | | EXISTING PIPE WILL HAVE TO BE INCREASED IN SIZE DUE TO | | | THE INCREASED LOAD OF THE SYSTEM. | | | | | | C) PLEASE PROVIDE A PIPING DETAIL AT THE METER SHOWING | | | THE TYPES AND SIZES OF INPUT AND OUTPUT PIPES AT THE | | | METER, LOCATIONS OF TEES, AND PE RISER CONNECTIONS- | | | SEC. 6.11.2.2 NFPA 58. | | | | | | D) PLEASE CORRECT THE 424,000 BTU LOAD SHOWN FOR THE | | | GENERATOR. BASED ON THE SUBMITTED SPECS THE LOAD IS | | | 340,000 BTU. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2022-05-31 10:41:58 | | | | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 22031099 | | | 5/31/2022 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | NFPA 58 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) GAS RISER: THE MOST RECENT GAS PERMIT IN THE WPB | | | BUILDING DEPARTMENT RECORDS THAT SHOWED THE FULL BTU | | | LOAD OF ALL GAS-FIRED APPLIANCES WAS PERMIT- 05081958. | | | THE GAS ISOMETRIC ON FILE SHOWS A TOTAL BTU LOAD OF | | | 920,000 WHICH INCLUDED A 400,000 BTU POOL HEATER. | | | PLEASE REVISE THE GAS RISER TO INCLUDE THE FOLLOWING | | | INFORMATION PER NFPA 58: | | | A) TOTAL BTU LOAD OF THE SYSTEM AND INDIVIDUAL | | | APPLIANCE BTU LOADS. PLEASE NOTE THE GENERATOR SPECS | | | SHOW A 340,000 BTU LOAD FOR THE GENERATOR. | | | B) SHOW THE TANK LOCATION AND THE TOTAL DEVELOPED | | | LENGTH OF THE SYSTEM FROM THE TANK TO THE MOST REMOTE | | | APPLIANCE OUTLET. | | | C) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | D) TYPES AND SIZES OF GAS PIPING. | | | E) LOCATIONS OF REGULATORS AND THE INPUT AND OUTPUT | | | PRESSURES. | | | F) PIPE SIZING TABLES. | | | | | | 2) THE GAS RISER SHALL BEAR THE PRINTED NAME, LICENSE | | | NUMBER AND SIGNATURE OF THE GAS PIPING INSTALLATION | | | CONTRACTER OR QUALIFIER WHO PREPARED THE DRAWING- SEC. | | | 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-08-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-08-16 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-08-10 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-08-10 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-08-03 |
Time |
06:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-05-31 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-05-12 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-05-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2022-03-24 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2022-08-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-17 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-17 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-04 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-04 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-08-04 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-08-04 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
08:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-03-24 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-03-24 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2022-03-24 14:35:52 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | | | | SIGNATURE REVIEW DENIED: | | | | | | THE SUBMITTALS ARE IN PROJECT DOX. | | | | | | THE AMERICAST GENERATOR PAD DOES NOT HAVE A THIRD PARTY | | | VERIFIED DIGITAL SIGNATURE. THE PAPER SUBMITTALS HAVE A | | | COPY OF THE ENGINEER'S DIGITAL SIGNATURE. PLEASE | | | PROVIDE SIGNATURES AS PER THE NOTES BELOW: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL | | | SIGNED/SEALED PAPER ORIGINAL TO: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2022-08-10 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-08-10 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-08-10 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-05-31 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-05-31 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2022-05-31 13:29:32 | 5/31/2022 FAILED | | | | | | NEW SURVEY UPLOADED ON 5/27/2022 SHOWS GENERATOR TO BE | | | 5 FEET FROM PROPERTY LINES | | | | | | AND NEEDS TO BE 6 FEET AWAY FROM THE PROPERTY LINE TO | | | COMPLY WITH THE ZONING CODE: | | | | | | PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR: | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET | | | INTO A REQUIRED SETBACK. | | | | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-05-24 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-05-24 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-05-24 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-04-05 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-04-05 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2022-04-05 14:26:35 | 4/5/2022 FAILED | | | | | | PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR: | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET | | | INTO A REQUIRED SETBACK. | | | | | | THE REQUIRED SETBACK FOR SF7 IS 15 FEET OR 10% OF LOT | | | DEPT WHICHEVER IS LESS, THEREFORE THE REQUIRED SETBACK | | | FOR THIS PROPERTY IS 10 FEET | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|