|
 |
 |
 |
 |
 |
Plan Review Details - Permit 22030994
| Plan Review Stops For Permit 22030994 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-18 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-18 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2022-07-18 09:07:21 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. PLEASE RESOLVE ISSUES WITH THE ENGINEERING REVIEW | | | FOR THIS ASSOCIATED PERMIT: | | | | | | 21110989 PRINTED COM-MISC 501 DATURA ST FLORIDA POWER & | | | LIGHT CO INSTALLATION OF AN ELECTRIC VEHICLE CHARGING | | | | | | 2. FBC107, THE PLANS UPLOADED SHOW SIGNIFICANT WORK | | | THAT IS NOT INCLUDED IN A RESTRIPE PERMIT. PLEASE | | | REMOVE. | | | | | | 3. FBC107, SCOPE NOT CLEAR. REVISE THE PERMIT | | | APPLICATION TO CLEARLY STATE SCOPE UNDER THIS PERMIT. | | | IT CURRENTLY STATES "INSTALL MONUMENT SIGN & ELECTRICAL | | | CAR CHARGING STATION . . . " IN BOX 5 (FURTHER WORK | | | DESCRIPTION) WITH "STRIPING" WRITTEN IN BOX 3 (TRADE). | | | | | | INCLUDE A CLEAR DESCRIPTION OF WORK IN BOX 5. SCOPE NOT | | | CLEAR, "STRIPING" HAS BEEN STATED BUT THE PLANS SHOW | | | RESURFACING. | | | | | | 4. PROVIDE A PLAN WHICH CLEARLY SHOWS WORK UNDER THIS | | | PERMIT - RESURFACING, STRIPING. CLEARLY SHOW SPACES, | | | ACCESSIBLE SPACES. | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2022-06-07 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-06-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-06-07 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-06-07 07:06:13 | I HAVE ASKED FOR A PGD PLAN SHOWING PROPOSED AND | | | EXISTING GRADES FOR THE DRIVEWAY AND ROADWAY AND HAVE | | | NOT RECEIVED ANYTHING TO DATE. | | | | | | | | | WITH REGARDS, | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | CITY OF WEST PALM BEACH | | | ENGINEERING SERVICES DEPARTMENT | | | 401 CLEMATIS ST., 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | PHONE: 561-494-1120 | | | FAX: 561-494-1116 | | | CELL 561-351-0510 | | | [email protected] | | | | | 2022-05-31 16:42:27 | SH - ENGINEERING ADDED, MISSED ON ORIGINAL SUBMITTAL | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-18 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-16 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-05-31 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
ckimmerl |
Date |
2022-05-31 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2022-05-31 10:52:43 | PROVISO: | | | | | | RE-STRIPING OF THE PARKING LOT NEEDS TO MEET CITY | | | PARKING STALL DIMENSIONS AND STRIPING DETAILS OF SEC. | | | 94-485. - GENERAL PROVISIONS. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |