| Plan Review Stops For Permit 22030918 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-01-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-01-14 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-01-14 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-08-20 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-08-20 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-14 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-13 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2022-07-14 07:42:38 | PLAN REVIEW BUILDING | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: NOTE ON PLAN PAGE D101.1-002 STATES THESE PLANS | | | ARE FOR EXTERIOR WORK ONLY. REMOVE THIS NOTE OR WORK | | | WILL BE LIMITED TO EXTERIOR WORK ONLY. | | | | | | NOTICE: BASED ON THE EXTENSIVE INTERIOR DEMO, | | | MECHANICAL, ELECTRICAL, PLUMBING AND FUEL GAS REVIEWS | | | ARE REQUIRED. | | | | | | 1. CITY OF WPB CHPT. VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. | | | | | | 1A. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. | | | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, | | | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE | | | OF WORK. | | | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY | | | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL | | | | | | 2. PROVIDE AN ARCHITECTURAL FLOOR PLAN. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 3. GAS WATER HEATER REMOVED. IDENTIFY THE SOURCE AND | | | LOCATION OF HOT WATER. | | | PLEASE PROVIDE THE SOURCE OF HOT WATER PER THE WPB | | | AMENDMENTS TO THE FBC SEC. 107.2.1. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. SECTION P2801.1 FBC RES. | | | P2801.1REQUIRED. HOT WATER SHALL BE SUPPLIED TO | | | PLUMBING FIXTURES AND PLUMBING APPLIANCES INTENDED FOR | | | BATHING, WASHING OR CULINARY PURPOSES. | | | | | | 4. PROVIDE SMOKE ALARMS PER R314. | | | R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-26 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-26 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-07-14 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-07-14 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2022-07-14 09:29:07 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | DEMO PLANS SHOWS REMOVAL OF INTEROR PARTITIONS, | | | ELECTRICAL PERMIT IS REQUIRED FOR SUCH DEMO. | | | | | | PLEASE SUBMIT AN ELECTRICAL PLAN FOR NEW WALL | | | INSTALLATION AND OUTLET AND SWITCH LAYOUT. 215.5 | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-17 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-19 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-19 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2022-08-19 09:52:31 | 1ST GAS REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC G2439.5 - PLEASE SHOW THE MAKE | | | UP/COMBUSTION AIR CALCS REQUIRED FOR THE GAS DRYER. | | | | | | 2. 2017 WPB AMENDS 107.2.1 - THE PLANS SHOW AN ATS FOR | | | A GENERATOR AND THE GENERATOR DOES NOT APPEAR TO BE ON | | | THE GAS RISER, PLEASE CLARIFY. | | | | | | 3. 2020 FRC G2413.3 - THE GAS DIAGRAM DOES NOT SHOW ANY | | | PIPE LENGTHS. PLEASE INDICATE THE LENGTHS USED, SYSTEMS | | | PRESSURES, AND GAS TABLES USED FOR PIPE SIZING. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-15 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-15 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2022-07-15 15:56:32 | EXTERIOR WORK ONLY. GAS TO BE DONE ON FUTURE PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-17 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-13 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-26 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-18 |
Time |
07:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-15 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-05-11 |
Time |
07:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-16 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-16 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-19 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-19 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2022-08-19 07:18:20 | 1) SHEET M101.1 HAS A NOTE AT MECH 103B THAT STATES: | | | NEW AHU- W/DISCONN. SEE MEP DWGS. BY OTHERS TYP. NO | | | OTHER DRAWINGS WERE SUBMITTED TO EXPLAIN THIS NOTE. | | | PROVIDE MORE INFORMATION ABOUT THIS NEW UNIT. IS THIS A | | | LIKE FOR LIKE CHANGE OUT WITH NEW DUCTWORK THROUGHOUT | | | THE RESIDENCE? IF SO PLEASE PROVIDE THE LIKE FOR LIKE | | | CHANGEOT FORM IDENTIFYING THE OLD AND THE REPLACEMENT | | | UNITS. FBC 107.3.5 | | | | | | 2) IS THE DRYER DUCT SHOWN ON THIS DRAWING NEW? IF SO, | | | PLEASE INDICATE THE TYPE, SIZE AND TERMINATION LOCATION | | | FOR THIS DRYER DUCT. FRC M1502 | | | | | | 3) THE GAS RANGE IDENTIFY'S THERE WILL BE A VENTED | | | HOOD. PROVIDE MORE DETAIL FOR THIS HOOD INCLUDING THE | | | FAN MOTER CFM'S AND THE TERMINATION LOCATION. ALSO | | | INCLUDE IF REQUIRED THE MAKEUP AIR FOR THIS HOOD.FRC | | | 1503 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-07-14 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-07-14 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2022-07-14 12:13:32 | PROVIDE A SCOPE OF WORK FOR THE MECHANICAL SYSTEMS ON | | | THIS PROJECT. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-17 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-01-17 06:47:56 | BATH #3 MARKED - SUBJECT TO FIELD INSPECTION | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-08-19 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-08-19 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2022-08-19 08:25:13 | 1ST PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. BATH #3 - 2020 FRC P3101.2.1 - THE WATER CLOSET IS | | | CONNECTED TO THE EXISTING BUILDING DRAIN WITH A VENT. | | | EACH FIXTURE DRAIN SHALL BE VENTED. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-15 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-15 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2022-07-15 15:56:01 | EXTERIOR WORK ONLY. PLUMBING TO BE DONE ON FUTURE | | | PERMIT. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-08-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-08-19 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-08-19 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-07-14 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-07-13 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-08-25 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-08-25 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-08-25 |
Time |
13:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2022-05-13 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-05-13 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-05-13 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|