Plan Review Details - Permit 22030682
Plan Review Stops For Permit 22030682
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-05-04 Cont ID  
Sent By dbattles Date 2022-05-04 Time 11:36 Rev Time 0.00
Received By dbattles Date 2022-05-04 Time 11:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-08 Cont ID  
Sent By pvalenti Date 2022-04-08 Time 15:16 Rev Time 0.00
Received By pvalenti Date 2022-04-08 Time 15:16 Sent To  
Notes
2022-04-08 15:25:08PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, THE TEST RESULTS THAT WERE SUBMITTED ARE
 FOR A 6" THICK SLAB WITH A DROPPED CEILING. THE PROBLEM
 WITH THAT SUBMITTAL IS THAT THERE IS NO DROP
 /DRYWALL CEILING EXCEPT IN MINIMAL AREAS OF THE KITCHEN
 AND POSSIBLY BATHROOM.
 PLEASE PROVIDE THE TEST RESULTS FOR 6" SLAB WITH NO
 DROP CEILING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-30 Cont ID  
Sent By pvalenti Date 2022-03-30 Time 08:38 Rev Time 0.00
Received By pvalenti Date 2022-03-30 Time 08:38 Sent To  
Notes
2022-03-30 09:06:56PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 PLEASE PROVIDE THE FOLLOWING INFORMATION:
  
 DESCRIPTION OF EXISTING SITE CONDITIONS:
 THICKNESS OF SLAB
 PROPOSED UNDERLAYMENT.
 TEST REPORTS FOR THE PROPOSED UNDERLAYMENT BASED ON THE
 EXISTING SITE CONDITIONS.
 TEST REPORTS MAY BE BASED ON THE FOLLOWING ASTM'S:
 E-84, E-90 & E-492.
  
  
 FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
 FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
  
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-03-23 Cont ID  
Sent By cwalker Date 2022-03-23 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-05-04 Cont ID  
Sent By dbattles Date 2022-05-04 Time 11:36 Rev Time 0.00
Received By dbattles Date 2022-05-04 Time 11:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-08 Cont ID  
Sent By pvalenti Date 2022-04-08 Time 15:25 Rev Time 0.00
Received By pvalenti Date 2022-04-07 Time 09:11 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-30 Cont ID  
Sent By pvalenti Date 2022-03-30 Time 09:07 Rev Time 0.00
Received By pvalenti Date 2022-03-18 Time 06:23 Sent To  
Notes
***NONE***