| 2022-08-31 17:17:46 | INSUFFICIENT |
| | |
| | 1) PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED |
| | SURVEYOR, THAT SHOWS THE RIGHT-OF-WAY LINE, THE |
| | SIDEWALK, AND ANY TREES WITHIN THE RIGHT-OF-WAY ALONG |
| | THE ENTIRE FIBER CONDUIT PATH SO THAT STAFF CAN VERIFY |
| | THAT THE BORE, OPEN TRENCH AND ANY REQUIRED BORE PIT |
| | AND HANDHOLES ARE WITHIN THE RIGHT-OF-WAY AND NOT ON |
| | PRIVATE PROPERTY. THE SURVEY NEEDS TO INCLUDE THE |
| | BROADWAY RIGHT-OF-WAY SECTIONS SO THAT STAFF CAN VERIFY |
| | THE WOK IS FULLY WITHIN THE RIGHT-OF-WAY. |
| | |
| | 2) THE ENGINEERING PLAN APPEARS TO SHOW THE EXCAVATION |
| | FOR HANDHOLE 03+42 AND BORE PIT 06-02 ON PRIVATE |
| | PROPERTY, WHICH IS NOT PERMITTED UNLESS THE SURVEY |
| | REQUIRED IN COMMENT #1 CLEARLY SHOWS A GENERAL UTILITY |
| | EASEMENT AT THE LOCATION. |
| | |
| | 3) THE CLOSEST EDGE OF THE EXCAVATION FOR BORE PIT |
| | 19+64 MUST SHOW A DIMENSION OF AT LEAST TEN FEET FROM |
| | THE TRUNK OF THE ADJACENT TREE WITHIN THE RIGHT-OF-WAY. |
| | THE TREE MUST BE SHOWN ON THE ENGINEERING PLAN. THE |
| | BORE MACHINE MAY NOT STAGE ADJACENT TO THE TREE. |
| | |
| | 4) THE CLOSEST EDGE OF THE EXCAVATION FOR BORE PIT |
| | 06-02 MUST SHOW A DIMENSION OF AT LEAST TEN FEET FROM |
| | THE TRUNK OF THE ADJACENT TREE WITHIN THE RIGHT-OF-WAY. |
| | THE TREE MUST BE SHOWN ON THE ENGINEERING PLAN. THE |
| | BORE MACHINE MAY NOT STAGE ADJACENT TO THE TREE. |
| | |
| | 5) THE TUBULAR MARKERS ARE NOT PERMITTED. MARKERS MAY |
| | ONLY BE INSTALLED WITHIN THE HANDHOLES OR OTHERWISE |
| | BURIED. |
| | |
| | 6) THE BORE DEPTH IS SUFFICIENT TO AVOID TREE ROOTS. |
| | |
| | 7) PROVIDE A COPY OF THE FDOT ROW PERMIT APPROVING THE |
| | WORK WITHIN THE BROADWAY RIGHT-OF-WAY. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |
| | |