| Plan Review Stops For Permit 22030664 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-22 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-22 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-21 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-21 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-18 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-18 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2022-07-18 15:42:51 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW FAILED: | | | | | | 4.) ROOFING UNDERLAYMENT MUST COMPLY WITH FBC R | | | 905.1.1.1. (DOUBLE UNDERLAYMENT OR OTHER APPROVED | | | METHOD). PLEASE SHOW METHOD OF COMPLIANCE ON PLAN. | | | 5.) FBC R 311.7.8.1, THE HANDRAILS CAN BE NO HIGHER | | | THAN 38" MEASURED VERTICALLY FROM THE SLOPED PLAIN | | | ADJOINING THE TREAD NOSING. PLEASE CORRECT THE HEIGHT | | | ON PLAN DETAILS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-06 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-06 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2022-07-06 13:19:50 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 4.) FBC B 107.2.1, PROVIDE THE PRODUCT APPROVALS FOR | | | ROOFING MATERIAL, WINDOWS, AND DOORS. | | | 5.) FBC B 107.2.1, PROVIDE ALL STAIR CONNECTION | | | DETAILS. | | | 6.) FBC R 312.1 & FBC B 1607.8.1.1, PROVIDE THE BALCONY | | | HAND RAIL CONNECTION DETAILS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-03 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-03 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2022-06-03 15:31:13 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, PLAN SHEET A-1 (EAST SIDE) INDICATES | | | A MEASUREMENT OF 38.28'. THIS APPEARS TO BE INCORRECT. | | | 2.) FBC B 107.2.1, PLAN SHEET A-1 (DESIGN CRITERIA) | | | INDICATES THE HIGHEST MEAN HEIGHT OF 15'. THIS APPEARS | | | TO BE INCORRECT. | | | 3.) FBC B 107.2.1, PLAN SHEET S-1 DETAILED SECTIONS | | | (H/S.1 & I/S.1) DO NOT MATCH THE INDICATIONS ON FLOOR | | | PLAN. THE DETAILS APPEAR TO BE MIXED UP. | | | 4.) FBC B 107.2.1, PROVIDE THE PRODUCT APPROVALS FOR | | | ROOFING MATERIAL, WINDOWS, AND DOORS. | | | 5.) FBC B 107.2.1, PROVIDE ALL STAIR CONNECTION | | | DETAILS. | | | 6.) FBC R 312.1 & FBC B 1607.8.1.1, PROVIDE THE BALCONY | | | HAND RAIL CONNECTION DETAILS. | | | 7.) FBC R 402, PROVIDE THE ENERGY CALCULATIONS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-29 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-29 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-04-11 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-04-11 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-11 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-06-23 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-06-23 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2022-06-23 10:08:47 | GAS SUB PERMIT REQUIRED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-22 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-21 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-21 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-21 |
Time |
08:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-18 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-15 |
Time |
06:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-06 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-06 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-17 |
Time |
07:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-03 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-03-16 |
Time |
09:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-07-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-07-23 |
Time |
06:52 |
Sent To |
|
|
| Notes |
| 2022-07-27 09:51:29 | 7/27/22 RECEIPT MU-2022-034208-0000 $ 546.52 PAID AO | | 2022-07-23 06:52:41 | 7/23/22 EMAILED IMPACT FOR REVIEW-AO |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-03 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-03 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2022-06-03 16:17:47 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | | YOUR PROJECT OR EMAIL IT TO [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-23 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-23 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-04-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-01 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-01 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2022-04-01 10:31:25 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-22030664 | | | | | | CODES IN EFFECT: | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE PROVIDE THE ENERGY CALCULATIONS FOR THIS | | | PROJECT. FEC 402 | | | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THIS PROJECT. FEC R403.7 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-18 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-18 |
Time |
07:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-06-24 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-06-23 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2022-06-23 10:07:23 | 2ND PLUMBING REVIEW | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC P3108.2.1 - THE POOL BATH HAS TWO TRAPS | | | UPSTREAM OF THE VENTED FIXTURE CONNECTION AND ONLY ONE | | | IS ALLOWED. THE LAVATOR WOULD NEED TO CONNECT BETWEEN | | | THE WATER CLOSET AND THE SHOWER TO BE IN COMPLIANCE. | | | | | | NOTE: I'VE ADDED A GAS REVIEW TO THIS PERMIT AS YOU | | | HAVE ADDED GAS TO THE DRAWING. YOU WILL NEED TO PULL A | | | GAS SUB-PERMIT OR A SEPARATE PERMIT FOR THE GAS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-23 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-03-23 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-03-23 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2022-03-23 10:36:02 | 03/23/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. ON SHEET P-2, THE TOILET IN THE MASTER DOES NOT HAVE | | | A HORIZONTAL WET VENT, AND IT IS A DRY VENT PER THE | | | 2020 R 3104.3 VENT CONNECTION TO THE DRAINAGE SYSTEM. | | | WHEN CORRECTING, IT MUST BE DOWNSTREAM OF BATHROOM | | | GROUPS OF THE WET VENT PER THE 2020 FBC SEC. | | | 3108.1HORIZONTAL WET VENT PERMITTED. | | | | | | 2. ON THAT SAME SHEET, THE LAV IS NOT SHOWN FOR THE | | | POOL CABANA. WOULD YOU PLEASE CORRECT PER THE WPB | | | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | THE LAUNDRY SINK CANNOT DISCHARGE INTO THE WET VET OF A | | | BATHROOM GROUP; IT MUST BE DOWNSTREAM PER THE 2020 FBC | | | SECTION R3108.1 HORIZONTAL WET VENT PERMITTED. | | | | | | 3. ON SHEET, E-1 SHOWS FOUR TANK-LESS, BUT IT HAS ONLY | | | TWO ON THE ISOMETRIC. WOULD YOU PLEASE CORRECT PER THE | | | WPB AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON | | | REQUEST. | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-03 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-03 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2022-06-03 16:20:07 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ANY ROOFING | | | WORK. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2022-07-22 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-22 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-22 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-07-21 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-07-21 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2022-07-21 09:09:17 | | | | SIGNATURE REVIEW DENIED: | | | | | | FS 471/FS 481 DOCUMENTS PREPARED BY AN | | | ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE | | | TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A | | | SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL. | | | UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY | | | VERIFIED) PLAN: | | | | | | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | BUILDING DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | FEEL FREE TO CONTACT ME AT 561 805 6673. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-07-18 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-07-18 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-07-18 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-06-29 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-06-29 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2022-06-23 14:34:59 | MECH DIGITAL SIGNATURES APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-06-03 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-06-03 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2022-04-01 10:34:28 | MECHANICAL SIGNATURES APPROVED. ME |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-06-24 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-06-24 |
Time |
09:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-03-18 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-03-18 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2022-03-18 11:14:26 | 03/18/22 FAILED BUILDING NEEDS TO BE MEASURED FROM | | | FINISHED GRADE. ELEVATION PLANS MEASURE FROM THE | | | FINISHED FLOOR ELEVATION. PLEASE CORRECT AND RESUBMIT | | | | | | ADDITIONALLY, PLEAE PROVIDE THE ROOF OVERHANG | | | MEASUREMENTS ON THE EAST AND WEST SIDES OF PROPOSED | | | BUILDING. CODE STATES THAT THEY CAN NOT PROTUDE MORE | | | THAN 3 FT INTO REQUIRED SETBACKS | | | | | | ALEXANDER FOWLKES | | | 5618221431 | | | [email protected] |
|
|