Plan Review Details - Permit 22030619
Plan Review Stops For Permit 22030619
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-05-11 Cont ID  
Sent By rmcphers Date 2022-05-11 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2022-05-11 Time 09:04 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-05-03 Cont ID  
Sent By rmcphers Date 2022-05-03 Time 10:47 Rev Time 0.00
Received By rmcphers Date 2022-05-03 Time 10:47 Sent To  
Notes
2022-05-03 10:47:26PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-05-11 Cont ID  
Sent By rmcphers Date 2022-05-11 Time 09:05 Rev Time 0.00
Received By rmcphers Date 2022-05-11 Time 09:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-03 Cont ID  
Sent By rmcphers Date 2022-05-03 Time 10:47 Rev Time 0.00
Received By rmcphers Date 2022-05-03 Time 10:47 Sent To  
Notes
2022-05-03 10:53:10CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE REQUIRED GRAB BAR BACKING LOCATION
 AND DETAILS PER FBC FHA REQUIREMENT 6 -REINFORCED WALLS
 FOR GRAB BARS.
 SECTION 100.205(C)(3)(III)REQUIRES THAT COVERED
 MULTIFAMILY DWELLINGS WITH A BUILDING ENTRANCE ON AN
 ACCESSIBLE ROUTE SHALL BE DESIGNED AND CONSTRUCTED IN
 SUCH A MANNER THAT ALL PREMISES WITHIN COVERED
 MULTIFAMILY DWELLING UNITS CONTAIN REINFORCEMENTS IN
 BATHROOM WALLS TO ALLOW LATER INSTALLATION OF GRAB BARS
 AROUND TOILET, TUB, SHOWER STALL AND SHOWER SEAT, WHERE
 SUCH FACILITIES ARE PROVIDED.
  
 2) PLEASE SHOW THE NEW CEILING HEIGHTS TO COMPLY WITH
 FBC 1208.2 MINIMUM CEILING HEIGHTS.
 OCCUPIABLE SPACES, HABITABLE SPACES AND CORRIDORS SHALL
 HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET 6 INCHES
 (2286 MM) ABOVE THE FINISHED FLOOR. BATHROOMS, TOILET
 ROOMS, KITCHENS, STORAGE ROOMS AND LAUNDRY ROOMS SHALL
 HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134 MM)
 ABOVE THE FINISHED FLOOR.
  
 3) FOR THE FLOORING - THE FOLLOWING ACUSTICAL TEST
 REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-04-18 Cont ID  
Sent By jleahy Date 2022-04-18 Time 13:30 Rev Time 0.00
Received By jleahy Date 2022-04-18 Time 13:30 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-08-02 Cont ID  
Sent By jleahy Date 2022-08-02 Time 10:15 Rev Time 0.00
Received By jleahy Date 2022-08-02 Time 10:15 Sent To  
Notes
2022-08-02 10:16:00TV, VOICE, AND DATA

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By pleduc Date 2022-05-09 Time   Rev Time 0.00
Received By pleduc Date 2022-05-09 Time 12:17 Sent To  
Notes
2022-05-09 12:19:06FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-03-31 Cont ID  
Sent By pleduc Date 2022-03-31 Time   Rev Time 0.00
Received By pleduc Date 2022-03-31 Time 12:45 Sent To  
Notes
2022-03-31 12:52:21FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-11 Cont ID  
Sent By rmcphers Date 2022-05-11 Time 09:08 Rev Time 0.00
Received By rmcphers Date 2022-05-07 Time 10:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-03 Cont ID  
Sent By rmcphers Date 2022-05-03 Time 10:53 Rev Time 0.00
Received By rmcphers Date 2022-03-30 Time 07:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-05-10 Cont ID  
Sent By rwbrown Date 2022-05-10 Time 14:39 Rev Time 0.00
Received By rwbrown Date 2022-05-10 Time 14:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-04-06 Cont ID  
Sent By lcrespo Date 2022-04-06 Time 09:46 Rev Time 0.00
Received By lcrespo Date 2022-04-06 Time 09:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-11 Cont ID  
Sent By rmcphers Date 2022-05-11 Time 09:08 Rev Time 0.00
Received By rmcphers Date 2022-05-11 Time 09:08 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-04-18 Cont ID  
Sent By jleahy Date 2022-04-18 Time 14:07 Rev Time 0.00
Received By jleahy Date 2022-04-18 Time 14:07 Sent To  
Notes
***NONE***