Plan Review Details - Permit 22030572
| Plan Review Stops For Permit 22030572 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-05-04 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-05-04 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-04-15 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-04-15 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2022-04-15 09:00:47 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.SEE F/D NOTE | | | 2.CORRECT ADDRESS | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-04-20 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-04-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-04-20 11:25:27 | FLOOR PLAN IN SUBMITTAL PACKAGE, PASSED. | | | | | | C. WALKER | | | [email protected] | | | | | | 561-804-4762 | | 2022-04-20 10:19:39 | FIRE REVIEW COMMENTS: | | | A FLOOR PLAN IS REQUIRED AS PART OF THE PERMIT | | | SUBMITTAL. NFPA 72 7.4.5 | | | | | | C. WALKER | | | 561-804-4762 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-03-29 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-03-29 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-03-29 10:42:27 | A FLOOR PLAN IS REQUIRED AS PART OF THE PERMIT | | | SUBMITTAL. NFPA 72 7.4.5 | | | PROVIDE THE CORRECT ADDRESS FOR THE LOCATION. | | | | | | FIRE REVIEW: | | | | | | C. WALKER, SENIOR FIRE INSPECTOR | | | 561-804-4762 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-05-04 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-04-19 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-04-15 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-03-28 |
Time |
13:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-04 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-04 |
Time |
06:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-04-15 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-04-15 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2022-04-15 10:09:29 | PLAN DENIED | | | ADDRESS ON APPLICATION AND PLAN DO NOT MATCH | | | SECTION 107 FBC 2020. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-05-04 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-05-04 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2022-04-15 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2022-04-15 |
Time |
09:01 |
Sent To |
|
|
| Notes |
|
|
|