Plan Review Details - Permit 22030541
Plan Review Stops For Permit 22030541
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 10:05 Rev Time 0.00
Received By shill Date 2022-07-24 Time 10:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-05-31 Cont ID  
Sent By cthroop Date 2022-05-31 Time 16:37 Rev Time 0.00
Received By dbattles Date 2022-05-31 Time 16:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 10:06 Rev Time 0.00
Received By shill Date 2022-07-01 Time 06:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-31 Cont ID  
Sent By dbattles Date 2022-05-31 Time 16:37 Rev Time 0.00
Received By dbattles Date 2022-04-04 Time 10:35 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-30 Cont ID  
Sent By hmoser Date 2022-06-30 Time 12:54 Rev Time 0.00
Received By hmoser Date 2022-06-30 Time 12:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-04-18 Cont ID  
Sent By medwards Date 2022-04-18 Time 09:40 Rev Time 0.00
Received By hmoser Date 2022-04-18 Time 08:22 Sent To  
Notes
2022-04-18 09:40:14PLAN DENIED
 REFER TO SECTION 107 FBC 2020 AIR HANDLERS AND
 CONDENSERS
 DON"T MATCH ON THE EQUIPMENT SCHEDULE.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-07-24 Cont ID  
Sent By shill Date 2022-07-24 Time 10:06 Rev Time 0.00
Received By shill Date 2022-07-24 Time 10:06 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-31 Cont ID  
Sent By dbattles Date 2022-05-31 Time 16:37 Rev Time 0.00
Received By dbattles Date 2022-05-31 Time 16:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-07-08 Cont ID  
Sent By afowlkes Date 2022-07-08 Time 09:08 Rev Time 0.00
Received By afowlkes Date 2022-07-08 Time 09:08 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By afowlkes Date 2022-04-12 Time 15:40 Rev Time 0.00
Received By afowlkes Date 2022-04-12 Time 15:40 Sent To  
Notes
2022-04-12 15:53:0904/12/22 FAILED - LOT DEPTH NEEDS TO BE CONFIRMED IN
 ORDER TO VERIFY REAR SETBACK. PLEASE PROVIDE A SURVEY
 TO VERIFY LOT WIDTH AND DEPTH. SOUTH BALCONY OF THE
 ACCESSORY STRUCTURE CAN ONLY ENCROACH 3 FT INTO FRONT
 SETBACK. SEE ARCHITECTURAL SITE PLAN FOR ADDITIONAL
 SETBACK COMMENTS
  
 NEED TO CONFIRM THE OVERALL FLOOR AREA OF THE ACCESSORY
 STUCTURE. MAXIMUM FLOOR AREA CANNOT EXCEED 1000 SQ FEET
  
 BUILDING PERMIT APPLICATION PACKET IS MISSING THE EAST
 ELEVATION PAGE. PLEASE INCLUDE THIS UPON RESUBMITAL.
  
 ON THE EXISTING ELEVATIONS, NEED TO INCLUDE OVERALL
 BUILDING HEIGHT (MEASURED FROM FINISHED GRADE TO MEAN
 ROOF HEIGHT), ACCESSORY STRUCTURE HEIGHTS (MEASURED
 FROM FINISHED GRADE TO MEAN ROOF HEIGHT), AND TOTAL
 CHIMNEY HEIGHTS
  
 ALEXANDER FOWLKES
 5618221431
 [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved