Plan Review Details - Permit 22030459
Plan Review Stops For Permit 22030459
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-04-12 Cont ID  
Sent By cpuell Date 2022-04-12 Time 12:59 Rev Time 0.00
Received By cpuell Date 2022-04-12 Time 12:59 Sent To  
Notes
2022-04-12 13:00:09PCN ESTABLISHED

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By cpuell Date 2022-03-09 Time 16:56 Rev Time 0.00
Received By cpuell Date 2022-03-09 Time 16:56 Sent To  
Notes
2022-03-09 16:56:34TOWN HOME WAS ISSUED THE ADDRESS OF 1947 DOCK ST AS
 PREVIOUSLY AGREED UPON. APPLICATION FORM NEEDS TO
 REFLECT THE CORRECT ADDRESS. A PARCEL CONTROL NUMBER
 NEEDS TO BE ESTABLISHED FOR THIS LOT, PLEASE SEE BELOW
 FOR INSTRUCTIONS:
 REQUEST A PALM BEACH COUNTY?S PARCEL SPLIT REQUEST FORM
 WHICH CAN BE FOUND AT THIS LINK
 HTTPS://WWW.PBCGOV.ORG/PAPA/DEPARTMENTS/GIS.HTM, THEY
 WILL ISSUE YOU WITH A UNIQUE PARCEL CONTROL NUMBER
 (PCN). WHEN YOU CONTACT THE PROPERTY APPRAISERS YOU
 NEED TO REQUEST PRELIMINARY LETTER OF THE PCN. ONCE YOU
 HAVE RECEIVED THE PRELIMINARY LETTER PLEASE CONTACT
 [email protected] OR CALL 561-805-6659 SO THAT I CAN
 ACTIVATE THE PARCEL.
 ALSO PLEASE NOTE THAT THE OVERALL PARCEL ADDRESS IS
 1919 DOCK ST WHICH WE WILL USE FOR THE COMMON AREAS AND
 THE NORTH BUILDING, THE SOUTH BUILDING WILL HAVE AN
 ADDRESS OF 1969 DOCK ST.
 CAROLINE PUELL
 ADDRESSING COORDINATOR
 [email protected]
 561-805-6659
  

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 2 Status P Date 2022-08-05 Cont ID  
Sent By scwelter Date 2022-06-06 Time 09:57 Rev Time 0.00
Received By scwelter Date 2022-08-05 Time 11:46 Sent To  
Notes
2022-06-06 09:58:36CONTACT [email protected]
  
 ART ASSESSMENT APPLICATION SEE PREVIOUS NOTES ON PUBLIC
 ART REQUIREMENT.

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 2022-05-18 Cont ID  
Sent By scwelter Date 2022-05-18 Time 13:32 Rev Time 0.00
Received By scwelter Date 2022-06-06 Time 09:57 Sent To  
Notes
2022-05-18 13:37:06 
 CONTACT [email protected]
 DEVELOPMENT SUBJECT TO PUBLIC ART REQUIREMENT. THIS
 PERMIT IS TIED TO PERMIT 22030459 AND INCLUDES
 22030466, 22030465, 22030463,
 22030461,22030460,22030459, 22030457,22030456,22030455,
 22030454,22030452,22030451,22030450
 CONTACT [email protected] FOR ART ASSESSMENT APPLICATION
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-08-11 Cont ID  
Sent By rmcphers Date 2022-08-11 Time 09:38 Rev Time 0.00
Received By rmcphers Date 2022-08-11 Time 09:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-07-26 Cont ID  
Sent By rmcphers Date 2022-07-26 Time 11:31 Rev Time 0.00
Received By rmcphers Date 2022-07-26 Time 11:31 Sent To  
Notes
2022-07-26 11:34:54NEW TOWNHOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT
 APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 (PER DRAWING S-7) THAN THE MAXIMUM SHOWN ON THE PRODUCT
 APPROVAL (-52.5) - SEE NOTE NUMBER 9 ON THE PRODUCT
 APPROVAL.
  
 2) ROOFING SYSTEM PRODUCT APPROVALS MAY BE DEFERRED
 SUBMITTALS BY LISTING ITEMS TO BE DEFERRED ON THE
 CONSTRUCTION DOCUMENTS - FBC WPB 107.3.4.1 DEFERRED
 SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED
 SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN
 THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL
 ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING
 OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS
 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE
 BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL
 ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
 THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A
 NOTATION INDICATING THAT THE DEFERRED SUBMITTAL
 DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
 CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-06-08 Cont ID  
Sent By rmcphers Date 2022-06-08 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2022-06-08 Time 13:21 Sent To  
Notes
2022-06-08 13:22:14NEW TOWNHOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) REVISED DRAWING A001 HAS BEEN UPLOADED TO PROJECTDOX
 ON TOP OF DRAWING A000 - PLEASE FIX
  
 2) ROOFING SYSTEM TO BE USED ON THE PROVIDED PRODUCT
 APPROVAL REQUIRES ADDITIONAL SIGNED AND SEALED
 ATTACHMENT DETAILS FROM AN ARCHITECT OR ENGINEER FOR
 ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A HIGHER PRESSURE
 (PER DRAWING S-7) THAN THE MAXIMUM SHOWN ON THE PRODUCT
 APPROVAL (-52.5) - SEE NOTE NUMBER 9 ON THE PRODUCT
 APPROVAL.
  
 3) PLEASE PROVIDE THE SMART FLOOD VENT PRODUCT APPROVAL
 OR ICC EVALUATION CERTIFICATE.
  
 4) ELEVATION CERTIFICATES NEED CORRECTIONS -
  
 A) A9(A) INCORRECT SQUARE FOOTAGE OF THE GARAGE SHOWN.
 B) A9(B) INCORRECT NUMBER OF FLOOD VENTS SHOWN.
 C) A9(C) PLEASE SHOW THE TOTAL SQUARE INCHES OF FLOOD
 OPENINGS.
 D) A9(D) SMART VENTS ARE ENGINEERED VENTS - SHOULD BE
 MARKED "YES".
  
 5) SITE PLAN SHOULD SHOW THE SITE DRAINAGE - OR PROVIDE
 THE CIVIL STORM WATER DRAINAGE PLAN -
 FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED
 WATER RETAINING SWALES)
  
 6) "PLUNGE POOL" - BARRIER SHOULD SURROUND THE POOL -
 THE GATE ON THE SIDE UNITS NEEDS TO BE SELF-CLOSING AND
 LATCHING PER FBC R4501.17.1.8
 ACCESS GATES, WHEN PROVIDED, SHALL BE SELF-CLOSING AND
 SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS
 R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED
 WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON THE POOL
 SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS LOCATED
 NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE
 GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON
 EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE
 REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY
 OPENING OR GAP FROM THE OUTSIDE. GATES THAT PROVIDE
 ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM
 THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By rmcphers Date 2022-04-12 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2022-04-11 Time 14:51 Sent To  
Notes
2022-04-12 08:03:07NEW TOWNHOUSE
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE EMERGENCY EGRESS FROM THE 2ND FLOOR
 BEDROOMS THAT LEAD DIRECTLY TO A PUBLIC WAY - FBC
 R310.1 EMERGENCY ESCAPE AND RESCUE OPENING REQUIRED.
 BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM
 SHALL HAVE NOT LESS THAN ONE OPERABLE EMERGENCY ESCAPE
 AND RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE
 SLEEPING ROOMS, AN EMERGENCY ESCAPE AND RESCUE OPENING
 SHALL BE REQUIRED IN EACH SLEEPING ROOM. EMERGENCY
 ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A
 PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A
 PUBLIC WAY.
  
 2) PLEASE PROVIDE THE PRODUCT APPROVAL FOR THE OVERHEAD
 GARAGE DOOR - THE GARAGE DOOR PRODUCT APPROVAL SHOWN ON
 THE DRAWINGS ALLOWS FOR BOTTOM VENTS OF 120 SQUARE
 INCHES MAX. - CUTTING HOLES IN THE GARAGE DOOR FOR
 FLOOD VENTS WILL VOID THE PRODUCT APPROVAL - PLEASE
 PROVIDE DETAILS FROM A DESIGN PROFESSIONAL TO INSTALL
 FLOOD VENTS IN THE OVERHEAD GARAGE DOOR BEYOND THE 120
 SQUARE INCHES ALLOWED BY THE PRODUCT APPROVAL.
  
 3) FLOOD VENTS SHOULD BE PLACED IN OPPOSITE SIDES OF
 THE BUILDING - PLEASE SHOW FLOOD VENTS IN THE SIDE OF
 THE BUILDING WHERE POSSIBLE FBC R322.2.2.1
  
 4) PLEASE SHOW THE REQUIRED WIND DESIGN PRESSURE FOR
 THE WINDOW AND DOOR OPENINGS FBC R301.2.1
  
 5) PLEASE PROVIDE THE ADDITIONAL ROOF SYSTEM ATTACHMENT
 DETAILS FROM A DESIGN PROFESSIONAL FOR WIND ZONES 2 AND
 3 AS NOTED ON THE ROOF SYSTEM PRODUCT APPROVAL.
  
 6) PLEASE SHOW THE "PLUNGE POOL" BARRIER FROM THE
 RESIDENCE PER FBC R4502.17.1
  
 7) PLEASE PROVIDE AN ELEVATION CERTIFICATE MARKED
 "CONSTRUCTION DRAWINGS" FBC WPB 107.3.5.3
  
 8) PLEASE SHOW EQUIPMENT ELEVATION IN THE GARAGE OR
 OUTSIDE THE BUILDING FBC R322.1.6 PROTECTION OF
 MECHANICAL, PLUMBING AND ELECTRICAL SYSTEMS.
 ELECTRICAL SYSTEMS, EQUIPMENT AND COMPONENTS; HEATING,
 VENTILATING, AIR CONDITIONING; PLUMBING APPLIANCES AND
 PLUMBING FIXTURES; DUCT SYSTEMS; AND OTHER SERVICE
 EQUIPMENT SHALL BE LOCATED AT OR ABOVE THE ELEVATION
 REQUIRED IN SECTION R322.2 OR R322.3.
  
 9) THE WALLS SEPARATING THE TOWNHOUSES CANNOT HAVE
 OPENINGS BELOW THE 2ND FLOOR IN THE COURT YARD AREA -
 FBC R302.2.1 CONTINUITY.
 THE FIRE-RESISTANCE-RATED WALL OR ASSEMBLY SEPARATING
 TOWNHOUSES SHALL BE CONTINUOUS FROM THE FOUNDATION TO
 THE UNDERSIDE OF THE ROOF SHEATHING, DECK OR SLAB. THE
 FIRE-RESISTANCE RATING SHALL EXTEND THE FULL LENGTH OF
 THE WALL OR ASSEMBLY, INCLUDING WALL EXTENSIONS THROUGH
 AND SEPARATING ATTACHED ENCLOSED ACCESSORY STRUCTURES.
  
 10) DRAWING S2 SHOWS A CUT SECTION (9/S6) AND (10/S6)
 WHICH SHOWS THE FLOOR SHEATHING RUNNING CONTINOUS
 THROUGH THE COMMON 2 HR RATED WALL FBC R302.2.1
 CONTINUITY.
 THE FIRE-RESISTANCE-RATED WALL OR ASSEMBLY SEPARATING
 TOWNHOUSES SHALL BE CONTINUOUS FROM THE FOUNDATION TO
 THE UNDERSIDE OF THE ROOF SHEATHING, DECK OR SLAB. THE
 FIRE-RESISTANCE RATING SHALL EXTEND THE FULL LENGTH OF
 THE WALL OR ASSEMBLY, INCLUDING WALL EXTENSIONS THROUGH
 AND SEPARATING ATTACHED ENCLOSED ACCESSORY STRUCTURES.
  
 11) A SEPARATE PERMIT IS REQUIRED FOR - SITE LIGHTING,
 FENCING, POOL.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-03-25 Cont ID  
Sent By jleahy Date 2022-03-25 Time 14:16 Rev Time 0.00
Received By jleahy Date 2022-03-25 Time 12:50 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-03-25 Cont ID  
Sent By jleahy Date 2022-03-25 Time 14:17 Rev Time 0.00
Received By jleahy Date 2022-03-25 Time 14:17 Sent To  
Notes
2022-03-25 14:18:01TV AND TELEPHONE/DATA JLEAHY

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2022-06-14 Cont ID  
Sent By rrossano Date 2022-06-14 Time   Rev Time 0.00
Received By rrossano Date 2022-06-14 Time   Sent To  
Notes
2022-06-14 14:42:50PASSED WITH PROVISO: UPLOAD APPROVED CIVIL PLANS FROM
 FORMAL ENGINEERING REVIEW E21100031.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB
 ENGINEERING SERVICES DEPARTMENT
 (561) 494-1098, FAX: (561) 494-1116 EMAIL:
 [email protected]
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-03-23 Cont ID  
Sent By rrossano Date 2022-03-23 Time   Rev Time  
Received By rrossano Date 2022-03-23 Time   Sent To  
Notes
2022-03-23 13:24:11UNDER FORMAL ENGINEERING SUBMITTAL REVIEW E21100031.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-07-22 Cont ID  
Sent By pleduc Date 2022-07-22 Time   Rev Time 0.00
Received By pleduc Date 2022-07-22 Time 11:42 Sent To  
Notes
2022-07-22 11:49:29FIRE PROVISO:
  
 ALL FIRE LINE UNDERGROUND & FIRE SPRINKLER WORK SHALL
 BE SUBMITTED UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 THE FIRE SPRINKLER SYSTEM IS REQUIRED TO BE MONITORED
 WITH THE FIRE ALARM WORK BEING SUBMITTED UNDER SEPARATE
 PERMITS & SHOP DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-06-07 Cont ID  
Sent By rwbrown Date 2022-06-07 Time 13:58 Rev Time 0.00
Received By rwbrown Date 2022-06-07 Time 13:56 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-03-25 Cont ID  
Sent By lcrespo Date 2022-03-25 Time 10:47 Rev Time 0.00
Received By lcrespo Date   Time   Sent To  
Notes
2022-03-25 10:48:4903/25/22 1ST GAS REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. A SUB GAS PERMIT IS REQUIRED BY A LICENSED
 CONTRACTOR FOR THE SCOPE OF WORK PER THE WPB AMENDMENTS
 TO THE FBC SEC. 105.1. PLEASE PLACE A NOT ON PLANS.
  
 2. WOULD YOU PLEASE SUBMIT EACH LENGTH OF ALL CUT
 SECTIONS OF PIPE ON THE ISOMETRIC DRAWING PER 2020 FBC
 RES. SECS. G2413.4.1, G2413.4.2.
  
 3. IS THE POOL HEATER IN A GARAGE? WOULD YOU PLEASE
 SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE FBC RES.
 SEC. G2407.1 AND G2439.4. IF THE LOUVER IS USED, SHOW
 THE LOUVERS' LOCATIONS THAT ARE BEING INSTALLED FOR THE
 COMBUSTION AIR. THE LOUVERS CANNOT BE LOCATED ON AN
 EXTERIOR WALL THAT IS FIRE RATED AS THE FIRE RATING OF
 THE WALL MUST BE MAINTAINED PER THE WPB AMENDMENTS TO
 FBC SEC.107.2.1. PLEASE PROVIDE VENTING DIAGRAMS
 SHOWING THE TYPE AND SIZE OF GAS VENTS, GAS VENT RUNS,
 AND TERMINATION LOCATIONS FOR POOL HEATER PER THE 2020
 FBC FG SEC. 503.
  
 4. SHOW THE DISTANCE FROM THE POINT OF THE DELIVERY GAS
 METER TO THE MOST REMOTE OUTLET IN THE BUILDING AND/OR
 SYSTEM PER THE 2020 FBC RES. SEC. G2413.4.1.
  
 5. LIST THE BTU LOAD OF EACH APPLIANCE WITH THE TOTAL
 BTU LOAD ON THE SYSTEM. REFER TO THE 2020 FBC RES. SEC.
 G2413.
  
 6. WOULD YOU PLEASE PROVIDE WHAT TYPE OF GAS (LP OR
 NATURAL) IS BEING USED PER THE WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 7. INDICATE THE SYSTEM'S DELIVERY PRESSURE (PSI) ON THE
 PLAN PER THE 2020 FBC RES. SEC. G2413.2.
  
 8. WOULD YOU PLEASE PROVIDE MANUFACTURES SPECIFICATIONS
 FOR ALL EQUIPMENT TO VERIFY COMPLIANCE WITH 2020 FBC
 RES. SEC. G2408.1. GAS APPLIANCES SHALL BE LISTED AND
 LABELED. THE INSTALLATION MANUALS FOR ALL GAS
 APPLIANCES/EQUIPMENT SHALL BE ONSITE AT THE TIME OF
 INSPECTION PER THE 2020 FBC RES. SEC. G2413.2 AND
 G2404.3.
  
 9. A GAS GRILL IS LABELED FOR OUTDOOR USE, AND IT SEEMS
 TO BE IN A COVERED PATIO; IF SO, PLEASE PROVIDE
 MANUFACTURERS RECOMMENDATION FOR A VENTILATION HOOD PER
 THE 2020 FG 305.1 OR 2020 FBC RES. SEC. G2408.1. A
 SEPARATE PERMIT MAY BE REQUIRED FOR HOOD PER THE WPB
 AMENDMENTS TO THE FBC SEC. 105.1.
  
 10. WOULD YOU PLEASE LABEL THE SHUTOFF VALVES AND DRIP
 LEGS ON GAS ISOMERIC PER THE 2020 FBC RES. SEC. G2420.5
 AND SHOW SHUT OFF ON THE MAIN METER, PLEASE.
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-08-15 Cont ID  
Sent By lmarchan Date 2022-08-15 Time 12:55 Rev Time 0.00
Received By lmarchan Date 2022-08-03 Time 13:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-07-27 Cont ID  
Sent By aoliver Date 2022-07-27 Time 14:09 Rev Time 0.00
Received By aoliver Date 2022-07-21 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-06 Cont ID  
Sent By rmcphers Date 2022-07-06 Time 08:50 Rev Time 0.00
Received By aoliver Date 2022-06-06 Time 07:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-13 Cont ID  
Sent By aoliver Date 2022-04-13 Time 09:04 Rev Time 0.00
Received By aoliver Date 2022-03-21 Time 09:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-08-26 Cont ID  
Sent By lmarchan Date 2022-08-26 Time 11:24 Rev Time 0.00
Received By lmarchan Date 2022-08-15 Time 12:55 Sent To  
Notes
2022-08-26 10:27:25RECEIPT MU-2022-039292-0000 $52,506.16 PAID AO
2022-08-15 12:55:298/15/22 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By rmcphers Date 2022-04-12 Time 08:03 Rev Time 0.00
Received By rmcphers Date 2022-04-12 Time 08:03 Sent To  
Notes
2022-04-12 08:05:09PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-13 Cont ID  
Sent By medwards Date 2022-06-13 Time 11:14 Rev Time 0.00
Received By medwards Date 2022-06-13 Time 11:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-25 Cont ID  
Sent By medwards Date 2022-03-25 Time 08:53 Rev Time 0.00
Received By medwards Date 2022-03-25 Time 08:30 Sent To  
Notes
2022-03-25 08:56:291ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22030459
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) AN ENERGY CALCULATION MUST BE SUBMITTED FOR EACH
 TOWN HOUSE, THIS SUBMITTAL MUST INCLUDE THE ADDRESS FOR
 EACH TOWNHOME. FBC EC R402
  
 2) A MECHANICAL EQUIPMENT SIZING CALCULATION MUST BE
 SUBMITTED FOR EACH TOWN HOUSE. FBC EC R403.7
  
 3) THE PERMIT APPLICATION MUST HAVE THE CORRECT ADDRESS
 FOR EACH TOWN HOUSE. FBC 107.2.1
  
 4) EACH TOWN HOUSE MUST HAVE A SEPARATE PERMIT
 APPLICATION. THE PERMIT APPLICATIONS ?WORK DESCRIPTION?
 STATES NEW CONSTRUCTION OF 7 TOWNHOUSES ON EACH
 APPLICATION SUBMITTED. PLEASE SHOW THAT EACH
 APPLICATION IS FOR A SPECIFIC ADDRESS AND PROJECT FOR
 THAT ADDRESS. FBC 107.2.1
  
 5) UNIT SHEETS: KEYNOTE 3 SPECS OUT A RE-CIRCULATING
 TYPE RANGE HOOD BUT IN THE SUPPORTING DOCUMENTS THERE
 IS A 600 CFM HOOD EXHAUST FAN. PLEASE EITHER SHOW THE
 DUCTWORK FOR THE HOOD AND THE TERMINATION LOCATION OR
 REMOVE THE 600 CFM HOOD MOTOR IN THE SUPPORTING
 DOCUMENTS FOR THIS SUBMITTAL. FBC 107.2.1
  
 6) PLEASE PROVIDE VENTILATION REQUIREMENTS FROM THE
 MANUFACTURER FOR THE POOL MOTOR AND POOL PUMPS THAT ARE
 LOCATED IN THE GARAGES. FBC 107.2.1
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2022-06-08 Cont ID  
Sent By rmcphers Date 2022-06-08 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2022-06-08 Time 13:22 Sent To  
Notes
2022-06-08 13:23:11FIRM = AE 12.1
  
 PROPOSED LOWEST FLOOR = 14.2 NAVD
  
 GARAGE FLOOR AT = 11.0 - WITH FLOOD VENTS

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status P Date 2022-04-12 Cont ID  
Sent By rmcphers Date 2022-04-12 Time 08:36 Rev Time 0.00
Received By rmcphers Date 2022-04-12 Time 08:36 Sent To  
Notes
2022-04-12 08:42:44FIRM = AE 12.1
  
 PROPOSED LOWEST FLOOR = 14.2
  
 GARAGE FLOOR AT = 11.0 - WITH FLOOD VENTS

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-06-07 Cont ID  
Sent By rwbrown Date 2022-06-07 Time 13:58 Rev Time 0.00
Received By rwbrown Date 2022-06-07 Time 13:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-03-25 Cont ID  
Sent By lcrespo Date 2022-03-25 Time 10:44 Rev Time 0.00
Received By lcrespo Date 2022-03-25 Time 09:08 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status N Date 2022-08-11 Cont ID  
Sent By rmcphers Date 2022-08-11 Time 09:38 Rev Time 0.00
Received By rmcphers Date 2022-08-11 Time 09:38 Sent To  
Notes
2022-08-11 09:38:50ROOFING SYSTEM TO BE DEFERRED

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2022-07-26 Cont ID  
Sent By rmcphers Date 2022-07-26 Time 11:35 Rev Time 0.00
Received By rmcphers Date 2022-07-26 Time 11:35 Sent To  
Notes
2022-07-26 11:35:37SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-06-08 Cont ID  
Sent By rmcphers Date 2022-06-08 Time 13:30 Rev Time 0.00
Received By rmcphers Date 2022-06-08 Time 13:30 Sent To  
Notes
2022-06-08 13:30:29SEE BUILDING PLAN REVIEW

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By rmcphers Date 2022-04-12 Time 08:05 Rev Time 0.00
Received By rmcphers Date 2022-04-12 Time 08:05 Sent To  
Notes
2022-04-12 08:05:57SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status P Date 2022-08-26 Cont ID  
Sent By dbattles Date 2022-08-26 Time 15:17 Rev Time 0.00
Received By dbattles Date 2022-08-26 Time 15:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-08-11 Cont ID  
Sent By rmcphers Date 2022-08-11 Time 09:50 Rev Time 0.00
Received By rmcphers Date 2022-08-11 Time 09:50 Sent To  
Notes
2022-08-11 09:50:55SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A203 DOES NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-07-26 Cont ID  
Sent By rmcphers Date 2022-07-26 Time 13:12 Rev Time 0.00
Received By rmcphers Date 2022-07-26 Time 13:09 Sent To  
Notes
2022-07-26 13:11:58SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A101, A102, A103, A201, A203, A302, A303,
 A401 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-06-08 Cont ID  
Sent By rmcphers Date 2022-06-08 Time 13:34 Rev Time 0.00
Received By rmcphers Date 2022-06-08 Time 13:34 Sent To  
Notes
2022-06-08 13:35:30SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWING SP-1 DOES NOT SHOW AS DIGITALLY SIGNED IN
 ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-04-12 Cont ID  
Sent By rmcphers Date 2022-04-12 Time 08:32 Rev Time 0.00
Received By rmcphers Date 2022-04-12 Time 08:32 Sent To  
Notes
2022-04-12 08:35:07SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) THE PROVIDED SURVEY AND SOIL REPORT DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  
2022-03-25 09:00:14MECHANICAL DIGITAL SIGNATURES APPROVED. ME

Review Stop Z ZONING
Rev No 4 Status P Date 2022-08-15 Cont ID  
Sent By llouie Date 2022-08-15 Time   Rev Time 0.00
Received By llouie Date 2022-08-15 Time   Sent To  
Notes
2022-08-15 09:56:59ZONING APPROVED WITH THE FOLLOWING PROVISOS:
  
 1.) A MINOR PLANNED DEVELOPMENT (PD) AMENDMENT FOR THE
 AS-BUILT SHALL BE REQUIRED PRIOR TO THE ISSUANCE OF THE
 FIRST CERTIFICATE OF OCCUPANCY (C.O.).
  
 2.) ALL CONDITIONS IN ORDINANCE NO. 4967-21 SHALL BE
 ADDRESSED PER THE TIMELINES SPECIFIED.
  
 3.) BASE BUILDING HEIGHT MEASUREMENT SHALL BE AT FEMA
 APPROVED ELEVATION. MAXIMUM BUILDING HEIGHT SHALL NOT
 EXCEED 30 FT. WITH EXCEPTION TO THE 10% ALLOWANCE FOR
 ARCHITECTURAL FEATURES.
  
 * SEE STAMPED SHEETS FOR ZONING APPROVAL AND NOTES.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2022-07-27 Cont ID  
Sent By llouie Date 2022-07-27 Time   Rev Time 0.00
Received By llouie Date 2022-07-27 Time   Sent To  
Notes
2022-07-27 11:32:37ZONING APPROVED WITH THE FOLLOWING PROVISOS:
  
 1.) A MINOR PLANNED DEVELOPMENT (PD)) AMENDMENT FOR THE
 AS-BUILT SHALL BE REQUIRED PRIOR TO THE ISSUANCE OF THE
 FIRST CERTIFICATE OF OCCUPANCY (C.O.).
  
 2.) ALL CONDITIONS IN ORDINANCE NO. 4967-21 SHALL BE
 ADDRESSED PER THE TIMELINES SPECIFIED.
  
 3.) BASE BUILDING HEIGHT MEASUREMENT SHALL BE AT FEMA
 APPROVED ELEVATION. MAXIMUM BUILDING HEIGHT SHALL NOT
 EXCEED 30 FT. WITH EXCEPTION TO THE 10% ALLOWANCE FOR
 ARCHITECTURAL FEATURES.
  
 * SEE STAMPED SHEETS FOR ZONING APPROVAL AND NOTES.

Review Stop Z ZONING
Rev No 2 Status F Date 2022-06-21 Cont ID  
Sent By llouie Date 2022-06-21 Time   Rev Time 0.00
Received By llouie Date 2022-06-21 Time   Sent To  
Notes
2022-06-21 11:10:17** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) MINOR CHANGES HAVE BEEN DETECTED THAT DO NOT MATCH
 THE APPROVED PLANS (I.E. ARCHITECTURAL, MINOR SITE
 DEVIATIONS, FLOOR PLANS, ETC.). A MINOR PD AMENDMENT IS
 REQUIRED PRIOR TO ZONING SIGN-OFF OF THIS PERMIT.
 PLEASE CONTACT ZONING STAFF FOR ADDITIONAL INFORMATION
 ON THE PROCESS (IF NECESSARY).
  
 2.) CONDITIONS OF APPROVAL PER ORDINANCE NO. 4967-21
 HAVE NOT BEEN MET. A TREE ALTERNATION PERMIT HAS YET TO
 BE SUBMITTED. THIS PERMIT SHOULD HAVE BEEN APPLIED FOR
 PRIOR TO SITE CLEARING, WHICH HAS ALREADY BEEN
 COMPLETED.
  
  
 NOTES:
  
 * CONDITIONS OF APPROVAL, PER ORDINANCE NO. MUST BE
 SATISFIED PRIOR TO THE ISSUANCE OF A PERMIT AND/OR
 CERTIFICATE OF OCCUPANCY (C.O.) FOR THIS PROJECT.
 PLEASE ENSURE ALL CONDITIONS ARE MET IN A TIMELY
 MANNER. SUPPORTING DOCUMENTATION WILL BE REQUIRED TO
 ENSURE ALL CONDITIONS HAVE BEEN MET.
  
 * SEPARATE PERMITS REQUIRED: SITE LIGHTING (INCLUDE
 PHOTOMETRICS), LIGHTING, PLUNGE POOL FOR LOT 14.
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: RPD (PARK CENTRAL)/ORDINANCE NO. 4967-21.
  
 * PLAT REFERENCE: RESOLUTION NO. 231-21 (PLAT BOOK/PAGE
 #: 133/100).
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-03-28 Cont ID  
Sent By llouie Date 2022-03-28 Time   Rev Time  
Received By llouie Date 2022-03-28 Time   Sent To  
Notes
2022-03-28 13:42:57** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) ALL PERMIT PLANS SHALL EXACTLY MATCH THE PLANS
 APPROVED BY ORDINANCE NO. 4967-21/CONDITIONAL SITE PLAN
 APPROVAL LETTER ISSUED BY PLANNING STAFF ON 11/19/2021.
 ANY DEVIATION TO THE PLANS (I.E. SITE PLAN, LANDSCAPE
 PLAN, ARCHITECTURAL DRAWINGS (FLOOR PLANS AND
 ELEVATIONS), UNIT SIZE, ETC.) WILL REQUIRE AN AMENDMENT
 TO THE PARK CENTRAL RESIDENTIAL PLANNED DEVELOPMENT
 (RPD). MINOR DEVIATIONS (I.E. UNIT SIZE, FLOOR PLANS,
 PROPOSED FENCING LOCATION, HOW DOES THE PROPOSED
 SMALLER BUILDING FOOTPRINT IMPACT BUILDING SETBACKS,
 ETC.) HAVE BEEN DETECTED IN THE PERMIT PLANS THAT DO
 NOT MATCH THE APPROVED SITE PLAN. PLEASE ADDRESS.
  
 2.) COMPLETE OVERALL SITE PLAN AND ASSOCIATED PLAN
 NOTES SHALL BE PROVIDED IN THE SITE PLAN. PLAN NOTES
 HAVE BEEN CUT OFF FROM THE SITE PLAN PROVIDED IN THE
 BUILDING PERMIT SET.
  
 3.) PLANS SHOW THE MECHANICAL EQUIPMENT LOCATED WITHIN
 THE GARAGE. PLEASE CLARIFY/CORRECT. ALSO THERE SEEMS TO
 BE A/C CONDENSER UNITS ON THE ROOFTOP FOR EACH UNIT;
 WHAT TYPE OF MECHANICAL EQUIPMENT IS PROVIDED ON THE
 FIRST LEVEL?
  
 4.) SINCE EACH UNIT IS BEING PROVIDED AS A SEPARATE
 PERMIT, A SURVEY OF EACH LOT IS REQUIRED AS PART OF THE
 PERMIT SUBMISSION.
  
 5.) ARCHITECTURAL ELEVATIONS HAVE NOT BEEN PROVIDED
 WITH THE PERMIT SUBMITTAL. ARCHITECTURAL ELEVATIONS ARE
 REQUIRED AS PART OF THE PERMIT PACKET.
  
 NOTES:
  
 * CONDITIONS OF APPROVAL, PER ORDINANCE NO. MUST BE
 SATISFIED PRIOR TO THE ISSUANCE OF A CERTIFICATE OF
 OCCUPANCY (C.O.) FOR THIS PROJECT. PLEASE ENSURE ALL
 CONDITIONS ARE MET IN A TIMELY MANNER. SUPPORTING
 DOCUMENTATION WILL BE REQUIRED TO ENSURE ALL CONDITIONS
 HAVE BEEN MET.
  
 * SEPARATE PERMITS REQUIRED: SITE LIGHTING (INCLUDE
 PHOTOMETRICS), PLUNGE POOL (UNIT 14), LANDSCAPING, ETC.
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: RPD (PARK CENTRAL)/ORDINANCE NO. 4967-21.
  
 * PLAT REFERENCE: RESOLUTION NO. 231-21 (PLAT BOOK/PAGE
 #: 133/100)
  