Plan Review Details - Permit 22030207
Plan Review Stops For Permit 22030207
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2023-07-25 Cont ID  
Sent By cpuell Date 2023-07-25 Time 16:59 Rev Time 0.00
Received By cpuell Date 2023-07-25 Time 16:59 Sent To  
Notes
2023-07-25 17:00:19ADDRESS CHANGED TO 413 @ WESTWOOD RD

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-06-14 Cont ID  
Sent By cpuell Date 2023-06-14 Time 09:47 Rev Time 0.00
Received By cpuell Date 2023-06-14 Time 09:47 Sent To  
Notes
2023-06-14 09:47:48AN @ ADDRESS NEEDS TO BE ASSIGNED TO THIS PROJECT.
 PLEASE EMAIL A SITE PLAN SHOWING THE EXACT LOCATION OF
 THE WHERE THE WORK IS TO BE DONE. IN THE FUTURE PLEASE
 MAKE SURE THAT YOU COORDINATE WITH
 [email protected] OR CALL 561-805-6659 BEFORE
 APPLYING FOR A PERMIT TO BE ISSUED AN @ ADDRESS.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By cpuell Date 2022-08-03 Time 13:10 Rev Time 0.00
Received By cpuell Date 2022-08-03 Time 13:10 Sent To  
Notes
2022-08-03 13:11:14PLEASE CONTACT [email protected], TO BE ASSIGNED A
 GENERIC PROPERTY CONTROL NUMBER FOR MCI METRO, ALSO
 PLEASE EMAIL A SITE PLAN SHOWING THE EXACT LOCATION OF
 THE WHERE THE WORK IS TO BE DONE. IN THE FUTURE PLEASE
 MAKE SURE THAT YOU COORDINATE WITH
 [email protected] OR CALL 561-805-6659 BEFORE
 APPLYING FOR A PERMIT TO BE ISSUED AN @ ADDRESS.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-08-16 Cont ID  
Sent By sberglun Date 2022-08-16 Time 14:56 Rev Time 0.00
Received By sberglun Date 2022-08-16 Time 14:55 Sent To  
Notes
2022-08-16 14:56:031) CITY UTILITIES ARE SHOWN INCORRECTLY ON PLANS.
 INCLUDE CITY UNDERGROUND UTILITIY PIPE SIZE, PIPE
 MATERIAL, AND DESCRIPTION ON BOTH PLAN VIEW AND PROFILE
 VIEW. CONTACT JANICE TARBILL, [email protected] FOR
 AS-BUILT INFORMATION. INCLUDE AS-BUILT INFORMATION IN
 YOUR RESUBMITTAL.
 2) ALL ROADWAY, SIDEWALK, AND SWALE RESTORATIONS ARE
 REQUIRED PER CITY STANDARD, PARTIAL SIDEWALK FLAG
 REPLACEMNTS ARE NOT ACCEPTABLE. PLEASE USE CITY OF WEST
 PALM BEACH STANDARD DETAILS.
  
 SUZANNE BERGLUND
 [email protected]
 561-494-1075
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2023-06-09 Time 08:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-25 Cont ID  
Sent By aoliver Date 2022-08-25 Time 08:20 Rev Time 0.00
Received By aoliver Date 2022-07-15 Time 17:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-08-25 Cont ID  
Sent By aoliver Date 2022-08-25 Time 08:20 Rev Time 0.00
Received By aoliver Date 2022-08-25 Time 08:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-24 Cont ID  
Sent By eschneid Date 2022-08-24 Time 10:39 Rev Time 0.50
Received By eschneid Date 2022-08-24 Time 10:39 Sent To  
Notes
2022-08-24 10:39:26INSUFFICIENT
  
 1) PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED
 SURVEYOR, THAT SHOWS THE RIGHT-OF-WAY LINE, THE
 SIDEWALK, AND ANY TREES WITHIN THE RIGHT-OF-WAY ALONG
 THE ENTIRE FIBER CONDUIT PATH SO THAT STAFF CAN VERIFY
 THAT THE BORE, OPEN TRENCH AND ANY REQUIRED BORE PIT
 AND HANDHOLES ARE WITHIN THE RIGHT-OF-WAY. THE SURVEY
 NEEDS TO INCLUDE THE LOCATION OF PROPOSED HANDHOLES
 00+74 AND 04+74, THE OPEN TRENCH AND THE BORE SECTION
 ALONG THE SOUTH DIXIE HIGHWAY SO THAT STAFF CAN VERIFY
 THAT THE PROPOSED WORK IS EXCLUSIVELY WITHIN FDOT
 RIGHT-OF-WAY AND NOT ON PRIVATE PROPERTY. IN ORDER TO
 INSTALL HANDHOLES AND BORE UNDER PRIVATE PROPERTY IS
 MUST BE IN A GENERAL UTILITY EASEMENT. THIS GENERAL
 UTILITY EASEMENT MUST BE CLEARLY SHOWN ON THE SURVEY.
  
 2) THE FINK MARKERS ARE NOT PERMITTED. MARKERS MAY ONLY
 BE INSTALLED WITHIN THE HANDHOLES OR OTHERWISE BURIED.
  
 3) THE BORE DEPTH IS SUFFICIENT TO AVOID TREE ROOTS.
  
 4) THE STREETLIGHT ADJACENT TO HANDHOLE 10+74 MUST BE
 SHOWN ON THE PLANS SO THAT STAFF CAN VERIFY THAT THERE
 IS NO CONFLICT WITH THE LIGHT POLE.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  
  
  