Plan Review Details - Permit 22030198
Plan Review Stops For Permit 22030198
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-03-23 Cont ID  
Sent By jbrooks Date 2022-03-23 Time 14:52 Rev Time 0.00
Received By jbrooks Date 2022-03-23 Time 08:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-03-17 Cont ID  
Sent By jbrooks Date 2022-03-17 Time 11:58 Rev Time 0.00
Received By jbrooks Date 2022-03-17 Time 07:45 Sent To  
Notes
2022-03-17 11:59:05JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-1109.03 COVERS
 MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1)
 THROUGH E(4). SELECT SYSTEM TO BE USED. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS. SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By jbrooks Date 2022-03-07 Time 09:43 Rev Time 0.00
Received By jbrooks Date 2022-03-07 Time 07:56 Sent To  
Notes
2022-03-07 09:43:50JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. SUBMITTED MIAMI-DADE COUNTY NOA 18-1109.03 COVERS
 MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1)
 THROUGH E(4). SELECT SYSTEM TO BE USED. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS.
 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND INCLUDE ROOF SLOPE(S), MEAN ROOF
 HEIGHT(S). LOW SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-23 Cont ID  
Sent By jbrooks Date 2022-03-23 Time 14:51 Rev Time 0.00
Received By jbrooks Date 2022-03-20 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-03-17 Cont ID  
Sent By jbrooks Date 2022-03-17 Time 11:59 Rev Time 0.00
Received By jbrooks Date 2022-03-10 Time 14:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-07 Cont ID  
Sent By jbrooks Date 2022-03-07 Time 09:43 Rev Time 0.00
Received By jbrooks Date 2022-03-04 Time 07:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status N Date 2022-03-23 Cont ID  
Sent By jbrooks Date 2022-03-23 Time 14:51 Rev Time 0.00
Received By jbrooks Date 2022-03-23 Time 08:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-10 Cont ID  
Sent By rmcphers Date 2022-03-10 Time 15:34 Rev Time 0.00
Received By rmcphers Date 2022-03-10 Time 15:34 Sent To  
Notes
2022-03-10 15:34:59ORIGINAL SIGNED AND SEALED ENGINEERING FROM AMD GROUP -
 TO STORAGE

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By jbrooks Date 2022-03-07 Time 09:42 Rev Time 0.00
Received By jbrooks Date 2022-03-07 Time 09:27 Sent To  
Notes
2022-03-07 09:42:54JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS IS A COPY OF A WET SIGNATURE. PROVIDE
 ORIGINAL DOCUMENTS.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME,
 OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND
 SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  


Account Summary | Usage Policy | Privacy Policy