Plan Review Details - Permit 22030166
Plan Review Stops For Permit 22030166
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-06-06 Cont ID  
Sent By shill Date 2022-06-06 Time 17:56 Rev Time 0.00
Received By shill Date 2022-06-06 Time 17:56 Sent To  
Notes
2022-06-06 18:03:30NOA FOR WALK IN COOLER HAS DP LIMITATION OF +70/-70PSF.
 SITE SPECIFIC DESIGN PRESSURES FOR SITE PREPARED BY
 DOUGLAS DEAN HARDIN, PE SPECIFY RISK CATEGORY II,
 IMPORTANCE FACTOR 1, 169MPH, +36.47/-46.04.
  
 PER THIS SITE:
  
 HTTPS://ASCE7HAZARDTOOL.ONLINE/
  
 SITE IS LOCATED IN 169MPH.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-05-31 Cont ID  
Sent By rmcphers Date 2022-05-31 Time 17:07 Rev Time 0.00
Received By rmcphers Date 2022-05-31 Time 17:07 Sent To  
Notes
2022-05-31 17:11:22EXTERIOR COOLER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) WIND DESIGN ON THE COOLER TIE DOWN CALCULATIONS AND
 THE DRAWINGS SHOW - RISK CAT. II WITH WIND SPEED OF
 169MPH - FOR A RISK CAT. II THE WIND SPEED SHOULD BE
 170MPH PER FBC WPB SECTION 120.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-05-09 Cont ID  
Sent By rmcphers Date 2022-05-09 Time 10:02 Rev Time 0.00
Received By rmcphers Date 2022-05-09 Time 10:02 Sent To  
Notes
2022-05-09 10:08:37EXTERIOR COOLER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE SIGNED AND SEALED BY AN ENGINEER OR
 ARCHITECT - COOLER ATTACHMENT TO THE FOUNDATION DETAILS
 SHOWING THE REQUIRED ANCHORAGE TYPE, SIZE AND LOCATION
 - AS STATED ON PAGE 1 OF 7 IN THE COOLER PRODUCT
 APPROVAL PROVIDED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-17 Cont ID  
Sent By rmcphers Date 2022-03-17 Time 16:15 Rev Time 0.00
Received By rmcphers Date 2022-03-17 Time 16:10 Sent To  
Notes
2022-03-17 16:14:28EXTERIOR COOLER
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE SIGNED AND SEALED COOLER ATTACHMENT
 TO THE FOUNDATION DETAILS SHOWING THE REQUIRED
 ANCHORAGE TYPE, SIZE AND LOCATION - AS STATED ON PAGE 1
 OF 7 IN THE COOLER PRODUCT APPROVAL PROVIDED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-05-09 Cont ID  
Sent By   Date 2022-05-09 Time   Rev Time 0.00
Received By jcclark Date 2022-05-09 Time 12:43 Sent To  
Notes
2022-05-09 12:43:20PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
 JOSEPH CLARK
 OFFICE OF THE FIRE MARSHAL
 561-804-4748
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-03-14 Cont ID  
Sent By   Date 2022-03-14 Time   Rev Time 0.00
Received By bdolan Date 2022-03-07 Time 13:28 Sent To  
Notes
2022-03-14 12:06:22PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-05-31 Cont ID  
Sent By rmcphers Date 2022-05-31 Time 17:12 Rev Time 0.00
Received By rmcphers Date 2022-05-22 Time 12:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-19 Cont ID  
Sent By cpuell Date 2022-05-19 Time 05:55 Rev Time 0.00
Received By cpuell Date 2022-05-07 Time 11:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-18 Cont ID  
Sent By lmarchan Date 2022-03-18 Time 10:33 Rev Time 0.00
Received By lmarchan Date 2022-03-04 Time 08:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-11 Cont ID  
Sent By medwards Date 2022-05-11 Time 15:49 Rev Time 0.00
Received By medwards Date 2022-05-11 Time 15:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By medwards Date 2022-03-09 Time 12:37 Rev Time 0.00
Received By medwards Date 2022-03-09 Time 12:37 Sent To  
Notes
2022-03-09 13:56:231ST REVIEW FBC-2020 MECHANICAL
 PERMIT-22030166
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE SHOW THE ANCHORAGE DETAILS FOR THE WALK-IN
 CONDENSING UNITS. FBC 107.2.1
  
 2) PLEASE SHOW PROTECTION FROM VEHICULAR TRAFFIC FOR
 THE CONDENSING UNITS. FBC M 303.4
  
 3) PLEASE SHOW THE CONDENSATION DISPOSAL LOCATION FOR
 THE WALK-IN. FBC M307
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-05-31 Cont ID  
Sent By rmcphers Date 2022-05-31 Time 17:12 Rev Time 0.00
Received By rmcphers Date 2022-05-31 Time 17:12 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-05-09 Cont ID  
Sent By rmcphers Date 2022-05-09 Time 10:26 Rev Time 0.00
Received By rmcphers Date 2022-05-09 Time 10:26 Sent To  
Notes
2022-05-09 10:28:00SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) FOUNDATION ATTACHMENT DRAWINGS DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR
 ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES
 NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN
 DROP OFF THE ORIGINAL SIGNED AND SEALED
 DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING
 DIVISION AT THE CITY HALL.
  
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-03-09 Cont ID  
Sent By medwards Date 2022-03-09 Time 13:57 Rev Time 0.00
Received By medwards Date 2022-03-09 Time 13:57 Sent To  
Notes
2022-03-09 14:00:26DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED,
 DATED ORIGINALS. A SCAN OF A WET / DIGITAL SIGNATURE IS
 NOT CONSIDERED A DIGITAL SIGNATURE. PLEASE SUBMIT
 DIGITALLY SIGNED DOCUMENTS.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-05-18 Cont ID  
Sent By llouie Date 2022-05-18 Time   Rev Time 0.00
Received By llouie Date 2022-05-18 Time   Sent To  
Notes
2022-05-18 15:06:25ZONING APPROVED WITH THE FOLLOWING PROVISO:
  
 1.) SUBJECT TO THE CONDITIONS IN THE CONDITIONAL
 APPROVAL LETTERS FOR ISPR 20-09 AND 20-09A.
  
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-03-18 Cont ID  
Sent By llouie Date 2022-03-18 Time   Rev Time 0.00
Received By llouie Date 2022-03-18 Time   Sent To  
Notes
2022-03-18 09:58:24** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) APPROVAL OF ISPR CASE NO. 20-09A REQUIRED PRIOR TO
 ZONING SIGN-OFF OF THIS PERMIT. ISPR 20-09A IS
 CURRENTLY PENDING/IN REVIEW WITH PPRC STAFF. ALL PLANS
 APPROVED UNDER ISPR 20-09A WILL NEED TO MATCH ALL
 BUILDING PERMIT PLANS.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: GC
  
 * REFERENCE: ISPR 20-09A (PIG BEACH MINOR SITE PLAN
 AMENDMENT).
  