| Plan Review Stops For Permit 22021436 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2022-04-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-24 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-23 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2022-04-18 08:48:24 | SHELL BUILD OUT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-06 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-20 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-20 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2022-04-20 16:59:34 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE THE FRONT PAGES OF THE PRODUCT | | | APPROVALS (FRONT PAGE SHOULD SHOW THE "APPLICATION | | | STATUS" AS APPROVED) - PLEASE PROVIDE A COMPLETE (FRONT | | | PAGES AND THE INSTALLATION INSTRUCTIONS) MIAMI DADE OR | | | FLORIDA STATE PRODUCT APPROVAL FOR THE NEW EXTERIOR | | | DOOR - ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND | | | MARKED APPROVED BY THE ARCHITECT OF RECORD FBC WPB | | | 107.3.4 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-24 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-23 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2022-03-24 09:41:47 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE NEW EXTERIOR DOOR - ALL | | | PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE ARCHITECT OF RECORD FBC WPB 107.3.4 | | | | | | 2) DRAWING G200 DETAILS A AND B SHOWS WALL TILE AT A | | | HEIGHT OF 3' 1 5/8" - PLEASE SHOW WALL FINISH AT | | | TOILETS AND URINALS TO COMPLY WITH FBC 1210.2.2 WALLS | | | AND PARTITIONS. | | | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE | | | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS | | | THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT | | | CONSIDERED A HARD SURFACE). | | | | | | 3) PLEASE SHOW IF TERMITE TREATMENT IS REQUIRED - | | | 1816.1.2 | | | IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE | | | PREVENTION, SOIL AREA DISTURBED AFTER INITIAL CHEMICAL | | | SOIL TREATMENT SHALL BE RETREATED WITH A CHEMICAL SOIL | | | TREATMENT | | | | | | 4) ACCESSIBLE RESTROOMS - PLEASE SHOW THE LOCATION | | | DIMENSIONS FOR THE TOILET PAPER HOLDER - FBC A 604.7 | | | DISPENSERS. | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE | | | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 | | | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND | | | SHALL NOT BE LOCATED BEHIND GRAB BARS. | | | | | | 5) ACCESSIBLE RESTROOMS - PLEASE USE THE WORDS | | | "REFLECTIVE SURFACE" OF THE MIRROR WHEN REFERRING TO | | | THE DIMENSIONS FROM THE FLOOR - FBC A 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. | | | | | | 6) ACCESSIBLE RESTROOM - PLEASE SHOW RESTROOM SIGNAGE | | | HEIGHT TO COMPLY WITH FBC A 703.4.1 HEIGHT ABOVE FINISH | | | FLOOR OR GROUND. | | | TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES | | | (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND | | | SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST | | | TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE | | | THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE | | | BASELINE OF THE HIGHEST TACTILE CHARACTER. | | | | | | 7) ACCESSIBLE RESTROOM - VERTICAL GRAB BAR IS NOT | | | REQUIRED PER FBC ACCESSIBILITY - PLEASE SHOW THE | | | CLEARANCE ABOVE THE GRAB BARS TO COMPLY WITH FBC A | | | 609.3 THE SPACE BETWEEN THE GRAB BAR AND PROJECTING | | | OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) MINIMUM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-04 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-05-04 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-21 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-21 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-21 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-21 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2022-03-21 11:27:51 | VOICE AND DATA JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-04-14 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-04-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-04-14 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2022-04-14 12:55:43 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-03-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
bdolan |
Date |
2022-03-18 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2022-03-18 12:25:52 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | | | | LT. BRIAN DOLAN | | | DIVISION OF FIRE PREVENTION | | | 561-804-4752 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-05-26 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-04 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2022-05-04 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2022-04-13 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-24 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-03 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-05-31 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-05-31 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-04-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-26 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-26 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-16 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-16 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2022-03-16 09:43:26 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-22021436 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SUBMIT THE ENTIRE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS. IF USING THE COMCHECK PLEASE USE THE | | | CORRECT CODE I.E. 2020 FLORIDA. FBC EC C403.2.1 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-05-31 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-05-31 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-04-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-04-14 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-04-14 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2022-04-14 08:23:09 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 22021436 | | | 4/14/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. COMMENT #1 FROM THE 1ST | | | REVIEW COPIED BELOW STILL EXISTS- PLEASE COMPLY. | | | | | | 1) FAILED P-001: THE WATER HEATER THERMOSTAT CANNOT | | | SERVE AS THE TEMPERATURE LIMITING MEANS FOR HOT WATER | | | SUPPLIES TO THE MOP SINK AND BREAK ROOM SINK. PLEASE | | | PROVIDE EITHER A MASTER THERMOSTATIC MIXING VALVE OR | | | MIXING VALVES AT EACH FIXTURE- SEC. 607.1.1 FBC P. THE | | | WATER HEATER DETAIL DOES NOT SHOW A MASTER THERMOSTATIC | | | MIXING VALVE AND INDIVIDUAL MIXING VALVES WERE NOT | | | PROVIDED AT THE MOP AND KITCHENETTE SINKS. IF USING A | | | MASTER VALVE PLEASE SEE SECTION 607.2.2: THE HOT WATER | | | OR TEMPERED WATER RETURN LINE SHALL BE ROUTED TO THE | | | COLD WATER INLET PIPE OF THE WATER HEATER AND THE COLD | | | WATER INLET PIPE OR THE HOT WATER RETURN CONNECTION OF | | | THE THERMOSTATIC MIXING VALVE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | CCOLE@WPB | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-16 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-16 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2022-03-16 09:31:30 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22021436 | | | 3/16/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P-001: THE WATER HEATER THERMOSTAT CANNOT SERVE AS | | | THE TEMPERATURE LIMITING MEANS FOR HOT WATER SUPPLIES | | | TO THE MOP SINK AND BREAK ROOM SINK. PLEASE PROVIDE | | | EITHER A MASTER THERMOSTATIC MIXING VALVE OR MIXING | | | VALVES AT EACH FIXTURE- SEC. 607.1.1 FBC P. A) PLEASE | | | INDICATE TEMPERED WATER WILL BE PROVIDED TO THE | | | LAVATORY SINK USING A MIXING VALVE THAT IS ASSE 1070 | | | APPROVED- SECS. 419.5 & 607.1.2 FBC P. | | | | | | 2) P-001: THE 1/2-INCH HW PIPE TO THE LAVATORY HAS | | | EXCEEDED THE MAXIMUM ALLOWABLE LENGTH FROM THE HW | | | SOURCE- SEC. C404.5.1 FBC EC. PROVIDE EITHER A | | | RECIRCULATION PUMP ON A POINT OF USE WATER HEATER. | | | | | | 3) P-001: INDICATE HOW TRAP SEAL PROTECTION WILL BE | | | PROVIDED FOR THE FLOOR DRAIN- SEC. 1002.4.1 FBC P. | | | | | | 4) P-001: A WATER HAMMER ARRESTOR IS REQUIRED FOR THE | | | WC FLUSH VALVE- SEC. 604.9 FBC P. | | | | | | 5) P-001: PLEASE ADD THE MOP SINK AND DRINKING FOUNTAIN | | | TO THE FIXTURE SCHEDULE- SECS. 410.1 & 422.1 FBC P. | | | | | | 6) P-001: PROVIDE HW PIPE INSULATION SPECIFICATIONS- | | | TABLE C403.2.10 FBC EC. | | | | | | 7) G-200: PROVIDE THE CLEAR FLOOR SPACE DIAGRAMS AND | | | DIMENSIONS FOR THE ACCESSIBLE WATER CLOSET AND | | | LAVATORY- SECS. 604.3 & 606.2 FBC ACC. | | | | | | 8) G-200: PROVIDE KNEE AND TOE CLEARANCES FOR THE | | | WHEELCHAIR ACCESSIBLE DRINKING FOUNTAIN AND THE SPOUT | | | AND BOTTLE FILLER HEIGHTS ABOVE THE FINISH FLOOR- SECS. | | | 306, 308 AND 602 FBC ACC. | | | | | | 9) G-200, A500: SHOW THE CLEAR FLOOR SPACE FORWARD | | | APPROACH DIAGRAM AND DIMENSIONS FOR THE BREAKROOM SINK, | | | AND THE REQUIRED KNEE AND TOE CLEARANCES- SEC. 306 & | | | 606.2 FBC ACC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-06-06 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2022-05-31 10:14:36 | DIGITAL SIGNATURE FOR MECHANICAL APPROVED ME |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-04-20 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-04-20 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-04-20 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2022-04-20 17:07:30 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE STRUCTURAL DRAWINGS PROVIDED DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | THE MECHANICAL DRAWINGS APPEAR TO HAVE A COPY OF THE | | | DIGITAL SIGNATURE. DIGITAL SIGNATURE REVIEW FAILED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-24 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-24 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2022-03-24 10:07:16 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ALL OF THE DRAWINGS PROVIDED DO NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | 2022-03-16 09:45:11 | THE MECHANICAL DRAWINGS APPEAR TO HAVE A COPY OF THE | | | DIGITAL SIGNATURE. DIGITAL SIGNATURE REVIEW FAILED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-06-03 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2022-06-03 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2022-06-03 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2022-06-03 15:03:01 | 6/3/22 ? PASSED | | | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. IN ACCORDANCE WITH THE CITY?S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION | | | 94-408(D)(1)(A), PLEASE ADD THE ADDRESS OF THE BUILDING | | | TO AT LEAST ONE (1) OF THE PROPOSED WALL MOUNTED SIGNS | | | ON THE EXTERIOR ELEVATIONS, SHEET A200. [SATISFIED] | | | 2. IN ACCORDANCE WITH ZLDR SUBSECTION 94-408(D)(1)(B), | | | PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING | | | BUILDING FA?ADES SIZE (SQUARE FOOTAGE) FOR WHERE THE | | | PROPOSED WALL MOUNTED SIGNS ARE LOCATED AND THE | | | (PERMITTED AND PROPOSED) WALL MOUNTED SIGNS SIZE | | | (SQUARE FOOTAGE) ON THE EXTERIOR ELEVATIONS, SHEET | | | A200. [SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRE A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 1. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [RESPONSE | | | PROVIDED AND SUBMITTAL PENDING] | | | 2. THE VALUE OF THE CONSTRUCTION ($650,000.00) EXCEEDS | | | 50% OF THE STRUCTURE'S VALUE ($340,000.00) ACCORDING TO | | | THE PALM BEACH COUNTY PROPERTY APPRAISER'S OFFICE; | | | THEREFORE, PURSUANT TO SUBSECTION 94-441(B) OF THE | | | ZLDR, THE LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. THEREFORE, PLEASE SUBMIT A LANDSCAPE PERMIT | | | APPLICATION OR A LANDSCAPE CONDITIONAL APPROVAL PERMIT | | | FORM. [SATISFIED] | | | | | | NEW COMMENT TO BE ADDRESSED: | | | 1. PLEASE PROVIDE THE WIDTH DIMENSION OF THE FRONT | | | STREET FA?ADE OF THE EXISTING BUILDING; PERMITTED WALL | | | MOUNTED SIGNS SIZE (SQUARE FOOTAGE) IN ACCORDANCE WITH | | | ZLDR SUBSECTION 94-408(D)(1)(B); AND PROPOSED WALL | | | MOUNTED SIGNS SIZE (SQUARE FOOTAGE) NOT EXCEEDING THE | | | PERMITTED WALL MOUNTED SIGN SIZE IN ACCORDANCE WITH | | | ZLDR SUBSECTION 94-408(D)(1)(B) ON THE EXTERIOR | | | ELEVATIONS, SHEET A200. [SATISFIED] | | | | | | | | | KEVIE DEFRANC | | | PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-04-15 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2022-04-15 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2022-04-15 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2022-04-15 09:55:23 | 4/15/22 ? FAILED | | | | | | PREVIOUS REVIEW COMMENTS TO BE ADDRESSED: | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. IN ACCORDANCE WITH THE CITY?S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION | | | 94-408(D)(1)(A), PLEASE ADD THE ADDRESS OF THE BUILDING | | | TO AT LEAST ONE (1) OF THE PROPOSED WALL MOUNTED SIGNS | | | ON THE EXTERIOR ELEVATIONS, SHEET A200. [SATISFIED] | | | 2. IN ACCORDANCE WITH ZLDR SUBSECTION 94-408(D)(1)(B), | | | PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING | | | BUILDING FA?ADES SIZE (SQUARE FOOTAGE) FOR WHERE THE | | | PROPOSED WALL MOUNTED SIGNS ARE LOCATED AND THE | | | (PERMITTED AND PROPOSED) WALL MOUNTED SIGNS SIZE | | | (SQUARE FOOTAGE) ON THE EXTERIOR ELEVATIONS, SHEET | | | A200. [PARTIALLY SATISFIED] | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRE A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 1. PLEASE SUBMIT A SIGN PERMIT APPLICATION. [NOT | | | SATISFIED] | | | 2. THE VALUE OF THE CONSTRUCTION ($650,000.00) EXCEEDS | | | 50% OF THE STRUCTURE'S VALUE ($340,000.00) ACCORDING TO | | | THE PALM BEACH COUNTY PROPERTY APPRAISER'S OFFICE; | | | THEREFORE, PURSUANT TO SUBSECTION 94-441(B) OF THE | | | ZLDR, THE LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. THEREFORE, PLEASE SUBMIT A LANDSCAPE PERMIT | | | APPLICATION OR A LANDSCAPE CONDITIONAL APPROVAL PERMIT | | | FORM. [NOT SATISFIED] | | | | | | NEW COMMENT TO BE ADDRESSED: | | | 1. PLEASE PROVIDE THE WIDTH DIMENSION OF THE FRONT | | | STREET FA?ADE OF THE EXISTING BUILDING; PERMITTED WALL | | | MOUNTED SIGNS SIZE (SQUARE FOOTAGE) IN ACCORDANCE WITH | | | ZLDR SUBSECTION 94-408(D)(1)(B); AND PROPOSED WALL | | | MOUNTED SIGNS SIZE (SQUARE FOOTAGE) NOT EXCEEDING THE | | | PERMITTED WALL MOUNTED SIGN SIZE IN ACCORDANCE WITH | | | ZLDR SUBSECTION 94-408(D)(1)(B) ON THE EXTERIOR | | | ELEVATIONS, SHEET A200. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-18 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2022-03-18 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2022-03-18 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2022-03-18 10:48:03 | 3/18/22 ? FAILED | | | | | | REVIEW COMMENTS TO BE ADDRESSED: | | | 1. IN ACCORDANCE WITH THE CITY?S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR) SUBSECTION | | | 94-408(D)(1)(A), PLEASE ADD THE ADDRESS OF THE BUILDING | | | TO AT LEAST ONE (1) OF THE PROPOSED WALL MOUNTED SIGNS | | | ON THE EXTERIOR ELEVATIONS, SHEET A200. | | | 2. IN ACCORDANCE WITH ZLDR SUBSECTION 94-408(D)(1)(B), | | | PLEASE IDENTIFY/INDICATE/DEMONSTRATE THE EXISTING | | | BUILDING FA?ADES SIZE (SQUARE FOOTAGE) FOR WHERE THE | | | PROPOSED WALL MOUNTED SIGNS ARE LOCATED AND THE | | | (PERMITTED AND PROPOSED) WALL MOUNTED SIGNS SIZE | | | (SQUARE FOOTAGE) ON THE EXTERIOR ELEVATIONS, SHEET | | | A200. | | | | | | ADDITIONAL REVIEW COMMENTS (THAT REQUIRE A SEPARATE | | | PERMIT) TO BE ADDRESSED: | | | 1. PLEASE SUBMIT A SIGN PERMIT APPLICATION. | | | 2. THE VALUE OF THE CONSTRUCTION ($650,000.00) EXCEEDS | | | 50% OF THE STRUCTURE'S VALUE ($340,000.00) ACCORDING TO | | | THE PALM BEACH COUNTY PROPERTY APPRAISER'S OFFICE; | | | THEREFORE, PURSUANT TO SUBSECTION 94-441(B) OF THE | | | ZLDR, THE LANDSCAPE ON THE SITE SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. THEREFORE, PLEASE SUBMIT A LANDSCAPE PERMIT | | | APPLICATION OR A LANDSCAPE CONDITIONAL APPROVAL PERMIT | | | FORM. | | | | | | | | | KEVIE DEFRANC | | | PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|