Plan Review Details - Permit 22021414
Plan Review Stops For Permit 22021414
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2022-03-23 Cont ID  
Sent By rrossano Date 2022-03-23 Time   Rev Time 0.00
Received By rrossano Date 2022-03-23 Time   Sent To  
Notes
2022-03-23 13:19:44PASSED WITH PROVISOS:
  
 CALL FOR LOCATES, DIAL 811 BEFORE YOU DIG. FOR MORE
 INFO ON "CALL BEFORE YOU DIG", GO TO
 HTTP://WWW.SUNSHINE811.COM (REF: UNDERGROUND FACILITY
 DAMAGE PREVENTION AND SAFETY ACT, FLORIDA STATUTE,
 CHAPTER 556.)
  
 ADDRESS ANY OUTSTANDING REVIEWERS COMMENTS.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-03-07 Cont ID  
Sent By ldeloren Date 2022-03-07 Time   Rev Time  
Received By ldeloren Date 2022-03-07 Time   Sent To  
Notes
2022-03-07 09:18:36GENERAL DRIVEWAY COMMENTS
 1) DIMENSION DRIVEWAYS, LOCATED HORIZONTALLY AND
 VERTICALLY. CALL OUT SETBACK (3 FEET FROM PROPERTY
 LINE).
 2) SHOW PROPOSED CONCRETE APRON(S), CONSTRUCT DRIVEWAY
 APRON IN COMPLIANCE WITH WPB CONSTRUCTION STANDARD
 DETAIL GC-5 (WHEN DISTANCE BETWEEN CURB OR EDGE OF
 PAVEMENT IS 10 FT. OR GREATER), OR STANDARD DETAIL GC-6
 (WHEN DISTANCE BETWEEN CURB OR EDGE OF PAVEMENT IS LESS
 THAN 10 FT.) CITY STANDARD DETAIL IS REQUIRED, SEE LINK
 BELOW: HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGIN
 EERING-STANDARDS-DETAILS
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-04-07 Cont ID  
Sent By afowlkes Date 2022-04-07 Time 15:23 Rev Time 0.00
Received By afowlkes Date 2022-04-04 Time 10:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-03-25 Cont ID  
Sent By afowlkes Date 2022-03-25 Time 09:49 Rev Time 0.00
Received By afowlkes Date 2022-03-25 Time 09:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-08 Cont ID  
Sent By aoliver Date 2022-03-08 Time 09:59 Rev Time 0.00
Received By aoliver Date 2022-03-02 Time 16:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-04-07 Cont ID  
Sent By afowlkes Date 2022-04-07 Time 15:23 Rev Time 0.00
Received By afowlkes Date 2022-04-07 Time 15:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-03-25 Cont ID  
Sent By afowlkes Date 2022-03-25 Time 09:49 Rev Time 0.00
Received By afowlkes Date 2022-03-25 Time 09:44 Sent To  
Notes
2022-03-25 09:49:2503/25/22 FAILED - THE PROPOSED DRIVEWAY EXPANSION ONLY
 LEAVES 818 SQ FEET OF LANDSCAPING IN THE FRONT YARD.
 PER CITY CODE, THE LESSER OF 1000 SQ FEET OR 75% OF THE
 FRONT YARD SHALL BE LANDSCAPED WITH LIVING PLANT
 MATERIAL. BY MY CALCULATIONS, THE FRONT YARD IS 1560 SQ
 FEET, THEREFORE THE LESSER REQUIRED VALUE IS 1000 SQ
 FEET. THE SITEPLAN MUST BE ADJUSTED TO PROVIDE MORE
 LANDSCAPED AREA WHILE STILL MEETING MINIMUM RADIUS,
 WIDTH, AND SETBACK REQUIREMENTS.
  
 ALEXANDER FOWLKES
 5618221431
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-03-04 Cont ID  
Sent By afowlkes Date 2022-03-04 Time 13:10 Rev Time 0.00
Received By afowlkes Date 2022-03-04 Time 12:09 Sent To  
Notes
2022-03-04 13:10:3503/04/22 FAILED - IF THE REQUIRED OFF STREET PARKING IS
 LOCATED IN THE FRONT YARD, THE LESSER OF 1,000 SQUARE
 FEET OR 75 PERCENT OF THE FRONT YARD AREA SHALL BE
 LANDSCAPED WITH LIVING PLANT MATERIAL. THE SITE PLAN
 DOES NOT SPECIFY THE SQUARE FOOTAGE OF THE PROPOSED AND
 EXISTING DRIVEWAYS, THEREFORE THIS CALCUALTION CANNOT
 BE MADE AND APPROVED. SEE CITY CODE SEC. 94-482 (A)
  
 EXPANSIONS TO EXISTING OFF-STREET PARKING SPACES AND
 DRIVEWAYS WITHIN A FRONT YARD OR A CORNER SIDE YARD
 SHALL BE SET BACK A MINIMUM OF FIVE FEET FROM A FRONT
 AND/OR CORNER SIDE PROPERTY LINE AND THREE FEET FROM A
 SIDE OR REAR PROPERTY LINE, EXCEPT FOR THAT PORTION OF
 THE DRIVEWAY ADJOINING THE APRON. THE SITE PLAN DOES
 NOT SPECIFY THE SETBACK DISTANCE OF THE PROPOSED
 DRIVEWAY. SEE CITY CODE SEC. 94-482 (D)(2)
  
 FOR CIRCULAR DRIVEWAYS THE INTERIOR ARC MAY BE AN
 IRREGULAR SHAPE, BUT SHALL HAVE A MINIMUM RADIUS OF
 FIVE FEET, THE SITE PLAN DOES NOT SPECIFY THE RADIUS OF
 THE PROPOSED CIRCULAR DIRVIEWAY. SEE CITY CODE SEC.
 94-482 (D)(5)
  
 FURTHERMORE, THE MAXIMUM WIDTH OF THE PAVED PORTIONS OF
 A CIRCULAR DRIVEWAY CANNOT EXCEED 10 FEET ON EITHER
 SIDE OF THE DRIVEWAY. THE PROPOSED DRIVEWAY MEETS THIS
 REQUIREMENT, BUT THE WIDTH OF THE EXISTING DRIVEWAY IS
 NOT SPECIFIED.
  
 ALEXANDER FOWLKES
 [email protected]
 561-822-1431
  
  
  


Account Summary | Usage Policy | Privacy Policy