Plan Review Details - Permit 22021315
Plan Review Stops For Permit 22021315
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-05-27 Cont ID  
Sent By shill Date 2022-05-27 Time 15:51 Rev Time 0.00
Received By shill Date 2022-05-27 Time 15:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-05-18 Cont ID  
Sent By jbrooks Date 2022-05-18 Time 14:33 Rev Time 0.00
Received By jbrooks Date 2022-05-18 Time 13:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-04-20 Cont ID  
Sent By jbrooks Date 2022-04-20 Time 12:57 Rev Time 0.00
Received By jbrooks Date 2022-04-20 Time 07:55 Sent To  
Notes
2022-04-20 12:57:51JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND
 SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR
 PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL
 LIMITATIONS #7 OF MIAMI-DADE NOA NO.: 20-0131.01.
 PLEASE NOTE THIS PROJECT IS LOCATED IN AN EXPOSURE D
 CATEGORY AREA; ALSO NOTE: THERE IS NOT A SYSTEM WITHIN
 THIS PRODUCT APPROVAL THAT WILL MEET OR EXCEED EXPOSURE
 D ZONE 3 MINIMUM DESIGN PRESSURE REQUIREMENT OF -131.42
 WITHOUT ENGINEER?S SIGN AND SEALED ENHANCED NAILING
 CALCULATIONS. SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-04-13 Cont ID  
Sent By jbrooks Date 2022-04-13 Time 13:05 Rev Time 0.00
Received By jbrooks Date 2022-04-13 Time 08:02 Sent To  
Notes
2022-04-13 13:06:29JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL18355-R7 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: COVER SHEET
 (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE
 VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT).
 2. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL10450-R15 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: COVER SHEET
 (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE
 VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL
 INFORMATION ABOUT THE PRODUCT).
 3. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND
 SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR
 PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL
 LIMITATIONS #7 OF MIAMI-DADE NOA NO.: 20-0131.01.
 PLEASE NOTE THIS PROJECT IS LOCATED IN AN EXPOSURE D
 CATEGORY AREA.
 4. FBC R 301 FAC9N-3 SUBMITTED STATE OF FLORIDA PRODUCT
 APPROVAL FL14826-R6 COVERS MULTIPLE SUBSTRATES AND
 REQUIRED ANCHORS TO ACHIEVE THE REQUIRED DESIGN
 PRESSURES. SELECT SUBSTRATE AND REQUIRED ANCHORS FROM
 PAGE #1 OF THE INSTALLATION ANCHORAGE DETAILS. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. SECOND
 REQUEST.
 5. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND INCLUDE ROOF SLOPE(S), MEAN ROOF
 HEIGHT(S). LOW SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE.
 SECOND REQUEST.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-10 Cont ID  
Sent By jbrooks Date 2022-03-10 Time 08:30 Rev Time 0.00
Received By jbrooks Date 2022-03-10 Time 07:24 Sent To  
Notes
2022-03-10 08:30:34JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL16709-R9 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO
 INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN
 BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE
 BOTTOM OF THE COVER PAGE. PRINT PAGES 1-4 ONLY.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R9 COVERS MULTIPLE ROOF SYSTEM TYPES
 A-2 THROUGH E, NO. W-1 THRU W-5. PLEASE SELECT SYSTEM
 NO.; EXPOSURE; ENCLOSURE; ROOF HEIGHT; ZONE AND
 ULTIMATE WIND SPEED. THE CORRECT EXPOSURE FOR THE
 LISTED ADDRESS IS EXPOSURE D. PRODUCT APPROVAL
 FL16709-R9 WILL NOT SATISFY EXPOSURE CATEGORY D
 ENCLOSED AREAS WITHOUT USING INSULATION OR PROVIDING
 ENGINEERED ENHANCED NAILING. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING.
 3. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL14826-R6 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-7 TO
 INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN
 BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE
 BOTTOM OF THE COVER PAGE. PRINT PAGES 1-7 ONLY.
 4. FBC R 301 FAC9N-3 SUBMITTED STATE OF FLORIDA PRODUCT
 APPROVAL FL14826-R6 COVERS MULTIPLE SUBSTRATES AND
 REQUIRED ANCHORS TO ACHIEVE THE REQUIRED DESIGN
 PRESSURES. SELECT SUBSTRATE AND REQUIRED ANCHORS FROM
 PAGE #1 OF THE INSTALLATION ANCHORAGE DETAILS. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 5. SUBMITTED PRODUCT APPROVAL FL18355-R6 HAS BEEN
 REVISED TO FL18355-R7. PLEASE PROVIDE A COMPLETE SET.
 ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3
 6. SUBMITTED PRODUCT APPROVAL FL10450-R14 HAS BEEN
 REVISED TO FL10450-R15. PLEASE PROVIDE A COMPLETE SET.
 ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3.
 7. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S). FLAT/LOW
 SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2022-05-27 Cont ID  
Sent By shill Date 2022-05-27 Time 15:51 Rev Time 0.00
Received By shill Date 2022-05-26 Time 13:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-05-26 Cont ID  
Sent By shill Date 2022-05-26 Time 10:17 Rev Time 0.00
Received By shill Date 2022-05-24 Time 10:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2022-05-22 Cont ID  
Sent By shill Date 2022-05-22 Time 13:15 Rev Time 0.00
Received By shill Date 2022-05-22 Time 13:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-05-18 Cont ID  
Sent By jbrooks Date 2022-05-18 Time 14:35 Rev Time 0.00
Received By jbrooks Date 2022-05-10 Time 14:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-04-20 Cont ID  
Sent By jbrooks Date 2022-04-20 Time 12:57 Rev Time 0.00
Received By jbrooks Date 2022-04-15 Time 09:43 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-13 Cont ID  
Sent By jbrooks Date 2022-04-13 Time 13:06 Rev Time 0.00
Received By jbrooks Date 2022-04-08 Time 06:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-10 Cont ID  
Sent By jbrooks Date 2022-03-10 Time 08:30 Rev Time 0.00
Received By jbrooks Date 2022-03-09 Time 08:39 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-05-27 Cont ID  
Sent By shill Date 2022-05-27 Time 15:50 Rev Time 0.00
Received By shill Date 2022-05-27 Time 15:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-05-26 Cont ID  
Sent By shill Date 2022-05-26 Time 10:11 Rev Time 0.00
Received By shill Date 2022-05-26 Time 10:11 Sent To  
Notes
2022-05-26 10:15:36THE ENGINEERING UPLOADED HAS AN IMAGE OF A DIGITAL
 SIGNATURE BUT IS NOT DIGIALLY SIGNED. AN EMAIL HAS BEEN
 SENT:
  
 [email protected]
 [email protected]
  
 PER FLORIDA STATUTE 471, DOCUMENTS PREPARED BY AN
 ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE
 SIGNED, SEALED DATED ORIGINALS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-05-22 Cont ID  
Sent By shill Date 2022-05-22 Time 13:15 Rev Time 0.00
Received By shill Date 2022-05-22 Time 13:15 Sent To  
Notes
2022-05-22 13:16:44FS471, THE ENGINEERING UPLOADED IS NOT DIGITALLY
 SIGNED. IT HAS THE IMAGE OF A DIGITAL SIGNATURE, BUT
 THE SIGNATURE CERTIFICATE IS NO LONGER ATTACHED TO THE
 PDF. UPLOAD A DIGITALLY SIGNED ORIGINAL. IF THE
 ENGINEER NEEDS ASSISTANCE IN UNDERSTANDING WHAT IS
 REQUIRED, HAVE HIM EMAIL ME AT [email protected].
  
 BLAKE E. JOYCE, PE
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-18 Cont ID  
Sent By jbrooks Date 2022-05-18 Time 14:34 Rev Time 0.00
Received By jbrooks Date 2022-05-18 Time 13:34 Sent To  
Notes
2022-05-18 14:34:49JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS CAN NOT BE VERIFIED. FS 668.003. NOTICE:
 FLORIDA PROFESSIONAL ENGINEERS MAY NOT SELF CERTIFY
 DIGITAL SIGNATURES AND SEALS; MUST BE THIRD PARTY
 CERTIFIED.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME,
 OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND
 SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  