| Plan Review Stops For Permit 22021234 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-05-03 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-05-03 |
Time |
07:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2022-04-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-04-12 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-04-12 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2022-04-12 14:00:11 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL DESIGN PROFESSIONAL TO CORRECT | | | DESIGN PRESSURES & NAILING PATTERNS. PROVIDE | | | CALCULATIONS AND NAILING PATTERNS FOR ZONE 1 PRIME, | | | ZONE 1, ZONE 2 & ZONE 3. PROVIDE BASE SHEET ATTACHMENT | | | PATTERNS (NUMBER OF ROWS OF FASTENERS AND SPACINGS). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-24 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-24 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2022-03-24 14:02:02 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED DESIGN PROFESSIONAL; TO CORRECT EXPOSURE | | | CATEGORY, DESIGN PRESSURES & NAILING PATTERNS. THE | | | EXPOSURE CATEGORY FOR 644 56TH STREET WEST PALM BEACH, | | | FL 33407 IS EXPOSURE CATEGORY C. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-01 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-01 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2022-03-01 09:14:49 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | 1. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT | | | LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 128. GENERAL | | | LIMITATION #7 IS SPECIFICALLY REFERRED TO IN THIS NOA. | | | SUBMIT FASTENER DENSITY CALCULATIONS PREPARED, SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT, OR REGISTERED ROOF | | | CONSULTANT. NOTE: THIS PROJECT IS LOCATED IN A CATEGORY | | | C AREA. | | | 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF SLOPE(S). FLAT/LOW | | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. | | | 3. INSPECTION WAIVERS/ROOFING AFFIDAVITS ARE NOT A PART | | | OF PLAN REVIEW. ALL INSPECTION MATTERS MUST BE ADDRESS | | | BY YOUR BUILDING INSPECTOR. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-05-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-05-03 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-04-25 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-04-12 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-04-12 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-04-07 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-24 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-23 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-01 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-02-28 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-04-07 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2022-04-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2022-04-07 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-03-24 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2022-03-24 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2022-03-24 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2022-03-24 14:03:17 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PROVIDE | | | ORIGINAL DOCUMENTS. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME, | | | OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND | | | SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO: | | | BUILDING DIVISION, FIRST FLOOR | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 1ST FLOOR | | | WEST PALM BEACH, FL 33401 | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|