| Plan Review Stops For Permit 22021058 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-17 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-17 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-12 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-12 10:52:36 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | PLEASE SHOW COOLER AND IDENTIFY ELECTRICAL POWER | | | CIRCUIT(S) FOR COOLER. 215.5 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-03-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-17 08:41:36 | FIRE PROVISO COMMENTS: | | | | | | LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, | | | A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION | | | FROM THE EGRESS SIDE. NFPA 101, LIFE SAFETY CODE, | | | 7.2.1.5.3 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2022-12-05 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-12-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-05 09:47:36 | FIRE PROVISO COMMENTS: | | | | | | LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE OF A KEY, | | | A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION | | | FROM THE EGRESS SIDE. NFPA 101, LIFE SAFETY CODE, | | | 7.2.1.5.3 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2022-12-01 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-12-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-12-01 11:19:01 | FIRE REVIEW COMMENTS: | | | | | | ADDRESS THE FOLLOWING COMMENTS ON THE PLAN. | | | | | | (1) WHAT IS THE TRAVEL DISTANCE FROM THE MOST REMOTE | | | POINT INSIDE THE WALK-IN COOLER TO AN APPROVED EXIT. | | | | | | (2) WHAT IS THE DOOR LOCKING HARDWARE ON THE WALK-IN | | | COOLER. | | | | | | (3) THERE IS NO INDICATION ON THE PLAN TO PROVIDE | | | EMERGENCY LIGHTING OR EXIT SIGNAGE INSIDE THE WALK-IN | | | COOLER. | | | | | | (4) THERE IS NO MENTION OF FIRE SPRINKLER COVERAGE | | | INSIDE THE WALK-IN COOLER. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2022-11-22 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-11-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-11-22 09:45:49 | FIRE REVIEW COMMENTS: | | | | | | ADDRESS THE FOLLOWING ON THE PLAN: | | | | | | (1) WHAT IS THE TRAVEL DISTANCE FROM THE MOST REMOTE | | | POINT INSIDE THE WALK- IN COOLER TO AN APPROVED EXIT? | | | | | | (2) WHAT IS THE DOOR LOCKING HARDWARE ON THE WALK-IN | | | COOLER DOOR? | | | | | | (3) NO INDICATION ON THE PLAN TO PROVIDE EMERGENCY | | | LIGHTING OR EXIT SIGNAGE INSIDE THE COOLER. | | | | | | (4) NO MENTION OF FIRE SPRINKLER COVERAGE INSIDE THE | | | WALK-IN COOLER. | | | | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2022-10-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2022-10-18 10:46:53 | FIRE REVIEW: | | | | | | ADDRESS THE FOLLOWING ITEM: | | | | | | (1) WHAT IS THE TRAVEL DISTANCE FROM THE MOST REMOTE | | | POINT TO AN EXIT? | | | | | | (2) WHAT IS THE DOOR LOCKING HARDWARE? | | | | | | (3) NO INDICATION OF EMERGENCY LIGHTING OR EXIT SIGNAGE | | | INSIDE THE COOLER. | | | | | | (4) NO MENTION OF FIRE SPRINKLER COVERAGE INSIDE THE | | | WALK IN COOLER. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-20 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-16 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-12 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-12-02 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-12-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-12-02 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-11-29 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-11-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-23 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-21 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-10-19 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2022-10-19 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-10-06 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-17 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-17 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2023-03-17 08:19:54 | IT APPEARS THAT THE ONLY DIFFERENCE IN THE PREVIOUSLY | | | APPROVED M2.1 SHEET AND THIS REVISED M2.1 SHEET IS THE | | | ENGINEERS SIGNATURE DATE. PLEASE EXPALIN THE REVISION | | | TO THIS M2.1 SHEET. | | | | | | ENGINEER CALLED ON 3/20/2023 AND EXPLAINED IT WAS | | | RESUBMITTED BECAUSE OF ELECTRICAL CHANGES. NO CHANGES | | | FROM PREVIOUS DRAWING EXCEPT DESIGNERS DIGITAL | | | SIGNATURE. APPROVED ME | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-30 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-30 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-11-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-23 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-23 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2022-11-23 07:52:06 | ENGINEER OF RECORD MUST DIGITALLY SIGN DIGITALLY | | | SUBMITTED DRAWINGS. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-18 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-18 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2022-10-18 06:42:58 | PROVIDE INFORMATION ABOUT THE WALK-IN COOLER INCLUDING | | | A COMPLETE DRAWING OF THE REFRIGERATION LINES AND THE | | | LOCATION OF THE CONDENSING UNIT FOR THE WALK-IN COOLER. | | | THE AMOUNT OF REFRIGERATION IN THIS SYSTEM, THE TYPE OF | | | REFRIGERANT. THE ALLOWABLE QUANTITIES OF REFRIGERANT. | | | | | | FMC 1102.1 GENERAL. THE SYSTEM CLASSIFICATION, | | | ALLOWABLE REFRIGERANTS, | | | MAXIMUM QUANTITY, ENCLOSURE REQUIREMENTS, LOCATION | | | LIMITATIONS, AND FIELD PRESSURE TEST REQUIREMENTS SHALL | | | BE | | | DETERMINED AS FOLLOWS: | | | 1. DETERMINE THE REFRIGERATION SYSTEM'S CLASSIFICATION, | | | IN | | | ACCORDANCE WITH SECTION 1103.3. | | | 2. DETERMINE THE REFRIGERANT CLASSIFICATION IN | | | ACCORDANCE | | | WITH SECTION 1103.1. | | | 3. DETERMINE THE MAXIMUM ALLOWABLE QUANTITY OF | | | REFRIGERANT | | | IN ACCORDANCE WITH SECTION 1104, BASED ON TYPE OF | | | REFRIGERANT, SYSTEM CLASSIFICATION AND OCCUPANCY. | | | 4. DETERMINE THE SYSTEM ENCLOSURE REQUIREMENTS IN | | | ACCORDANCE | | | WITH SECTION 1104. | | | 5. REFRIGERATION EQUIPMENT AND APPLIANCE LOCATION AND | | | INSTALLATION SHALL BE SUBJECT TO THE LIMITATIONS OF | | | CHAPTER | | | 3. | | | 6. NONFACTORY-TESTED, FIELD-ERECTED EQUIPMENT AND | | | APPLIANCES | | | SHALL BE PRESSURE TESTED IN ACCORDANCE WITH SECTION | | | 1108. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-17 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-17 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2022-12-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-12-12 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-11-30 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-30 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-30 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-11-23 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-11-23 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-11-23 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2022-11-23 07:54:04 | ENGINEER OF RECORD MUST DIGITALLY SIGN DIGITALLY | | | SUBMITTED DRAWINGS. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-10-18 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-10-18 |
Time |
06:43 |
Sent To |
|
|
| Notes |
|
|