| Plan Review Stops For Permit 22021050 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-21 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-21 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-05-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-18 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-18 |
Time |
05:35 |
Sent To |
|
|
| Notes |
| 2022-05-18 08:31:40 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | 1. PROVIDE A SITE PLAN.... | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE | | | AND INCLUDED BOUNDARY LINE SURVEY. | | | (MISSING BOUNDARY LINE SURVEY) | | | | | | 2. CORRECTED. | | | | | | 3. N/A | | | | | | 4. PROVIDE THE ICC-ES REPORT FOR THE SPRAY APPLIED | | | INSULATION. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | (NOT ADDRESSED) | | | | | | 5. PROVIDE THE PRODUCT APPROVALS FOR THE PROPOSED SGD | | | AND SH WINDOWS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | (PROVIDE THE FL PRODUCT APPROVAL COVER SHEETS FOR THE | | | PROPOSED EXT. SGD-9400 | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.) | | | | | | 6. CORRECTED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-18 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2022-03-21 09:58:02 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | BU1635 BN4338 | | | ASFPM CFM US-21-11935 | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE A SITE PLAN.... | | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | | AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE | | | AND INCLUDED BOUNDARY LINE SURVEY. | | | | | | 2. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | | INCLUDED BOUNDARY LINE SURVEY. | | | | | | 3. SUBMIT THE TRUSS DRAWINGS, REVIEWED AND APPROVED BY | | | THE DESIGNER OF RECORD. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 4. PROVIDE THE ICC-ES REPORT FOR THE SPRAY APPLIED | | | INSULATION. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 5. PROVIDE THE PRODUCT APPROVALS FOR THE PROPOSED SGD | | | AND SH WINDOWS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | 6. PROVIDE THE ROUGH OPENING DEMENSIONS FOR THE SGD AND | | | SH WINDOWS. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-18 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-18 |
Time |
05:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-21 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2022-03-21 09:28:22 | ELECTRICAL PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.AN ELECTRICAL SUB-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2.PROVIDE AN UPDATED PANEL SCHEDULE | | | PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | | | 3. PROVIDE SMOKE ALARMS. | | | FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A | | | BUILDING. | | | WHERE AN ADDITION IS MADE TO A BUILDING OR STRUCTURE OF | | | A GROUP R OR I-1 OCCUPANCY, THE EXISTING BUILDING SHALL | | | BE PROVIDED WITH SMOKE ALARMS AS REQUIRED BY THE | | | FLORIDA FIRE PREVENTION CODE OR SECTION R314 OF THE | | | FLORIDA BUILDING CODE, RESIDENTIAL AS APPLICABLE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-21 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-02 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-05-20 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-20 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-17 |
Time |
18:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-02-23 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-06-27 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-06-21 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2022-06-27 16:44:13 | RECEIPT MU-2022-029354 - $0.00 NO FEES DUE. LEM | | 2022-06-21 11:39:17 | 6/21/22 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-21 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2022-03-21 09:57:06 | PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS | | | | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT | | | LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO | | | THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF. | | | THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ | | | B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE | | | RECEIPT TO PROJECT DOX OR EMAIL IT TO | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2022-06-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-06-11 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-06-11 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2022-05-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-18 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-18 |
Time |
05:36 |
Sent To |
|
|
| Notes |
| 2022-05-18 08:05:06 | PLAN REVIEW MECHANICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 2ND REVIEW | | | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. SEE | | | BELOW: | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. A MECHANICAL SUB-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE AN ENERGY SUBMITTAL. | | | SUBMIT AN ENERGY COMPLIANCE REPORT FOR THE ADDITION PER | | | FBC EC R101.5.1.1 | | | R101.5.1.1.1BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE CODE OFFICIAL TO DEMONSTRATE | | | CODE COMPLIANCE BY THIS METHOD. ALTERNATIVELY, A | | | FLORIDA RESCHECK COMPUTER PRINTOUT MAY BE SUBMITTED TO | | | DEMONSTRATE COMPLIANCE BY SECTIONS R402, R403 AND R404. | | | | | | 3. PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | R403.7HEATING AND COOLING EQUIPMENT (MANDATORY). | | | FBC E R403.7.1EQUIPMENT SIZING. | | | HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN | | | ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT | | | LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR | | | OTHER APPROVED HEATING AND COOLING CALCULATION | | | METHODOLOGIES, BASED ON BUILDING LOADS FOR THE | | | DIRECTIONAL ORIENTATION OF THE BUILDING. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-21 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2022-03-21 09:07:00 | PLAN REVIEW MECHANICAL | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2017 NEC | | | | | | 1ST REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. A MECHANICAL SUB-PERMIT IS REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 2. PROVIDE AN ENERGY SUBMITTAL. | | | SUBMIT AN ENERGY COMPLIANCE REPORT FOR THE ADDITION PER | | | FBC EC R101.5.1.1 | | | R101.5.1.1.1BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE CODE OFFICIAL TO DEMONSTRATE | | | CODE COMPLIANCE BY THIS METHOD. ALTERNATIVELY, A | | | FLORIDA RESCHECK COMPUTER PRINTOUT MAY BE SUBMITTED TO | | | DEMONSTRATE COMPLIANCE BY SECTIONS R402, R403 AND R404. | | | | | | 3. PROVIDE EQUIPMENT SIZING CALCULATIONS. | | | R403.7HEATING AND COOLING EQUIPMENT (MANDATORY). | | | FBC E R403.7.1EQUIPMENT SIZING. | | | HEATING AND COOLING EQUIPMENT SHALL BE SIZED IN | | | ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT | | | LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR | | | OTHER APPROVED HEATING AND COOLING CALCULATION | | | METHODOLOGIES, BASED ON BUILDING LOADS FOR THE | | | DIRECTIONAL ORIENTATION OF THE BUILDING. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2022-03-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-03-21 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-03-21 |
Time |
07:18 |
Sent To |
|
|
| Notes |
| 2022-03-21 07:24:40 | 3/21/22 PROVISO ON PLAN PAGE A2: A SEPERATE ROOFING | | | PERMIT IS REQUIRED. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-06-21 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-06-21 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2022-05-18 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2022-05-18 |
Time |
05:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-24 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-24 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2022-02-24 15:52:03 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | FS471/FS481 DOCUMENTS PREPARED BY AN ARCHITECT OR | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED, SEALED, DATED ORIGINALS OR DIGITALLY SEALED AND | | | SIGNED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-06-10 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-06-10 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-06-10 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-05-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-05-20 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2022-05-20 08:35:19 | 5/20/2022 | | | FAIL | | | ARTICLE III. SECTION 94-72 STATES PRINCIPLE BUILDING | | | STRUCTURES LOCATED IN SINGLE FAMILY LOW DENSITY ZONING | | | (SF7) THE REAR SETBACK IS 15 FT OF 10 PERCENT THE LOT | | | DEPTH WHICHEVER IS LESS. | | | | | | | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2022-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2022-02-28 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2022-02-28 12:58:33 | 2/28/2022 | | | FAILED | | | PLEASE PROVIDE A SURVEY SHOWING THE SIDE AND REAR | | | SETBACK. | | | | | | ALEXIS SANGELEER | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|