Plan Review Details - Permit 22020985
| Plan Review Stops For Permit 22020985 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-05-14 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-14 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2022-05-14 13:14:41 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC 107 PLANS ARE ILLEGIBLE. PLEASE CONTACT THE | | | ENGINEER, ASK FOR DIGITALLY SIGNED PDFS. EACH PAGE | | | SHOULD BE A SEPARATE PDF AND SHOULD BE DIGITALLY | | | SIGNED. SINCE THE PLANS WERE PREPARED BY A STRUCTURAL | | | ENGINEER THEY ARE LIKELY COMPLIANT BUT I CANNOT READ | | | THE INFORMATION ON THE PLAN. THIS IS REQUIRED TO | | | DETERMINE CODE COMPLIANCE AND TO PERFORM INSPECTIONS. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-05-14 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-02-23 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-05-14 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-14 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2022-05-14 13:15:09 | SEE BUILDING COMMENTS | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-02-25 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2022-02-25 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2022-02-25 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2022-02-25 14:12:37 | 2/25/22**** FAILED **** | | | | | | PURSENT TO CODE SECTION 94-304 (B)(3) BUILDING | | | SEPARATION. ACCESSORY STRUCTURES COVERED WITH A SOLID | | | ROOF SHALL BE LOCATED NO CLOSER THAN SIX FEET TO THE | | | PRINCIPAL STRUCTURE. ACCESSORY STRUCTURES LESS THAN SIX | | | FEET FROM THE PRIMARY STRUCTURE MUST MEET THE PRIMARY | | | STRUCTURE SETBACKS. | | | | | | SF14 SETBACKS ARE 25 FEET FROM TEH FRONT PROPERTY LINE, | | | MINUMUM OF 5 FEET FROM SIDE PROPERTY AND MUST TOTATL 15 | | | FEET WHEN ADDING BOTH SIDE SETBACKS TOGETHER, AND 15 | | | FEET OR 10 PERCENT; WHICHEVER IS LESS FROM THE REAR | | | PROPERTY | | | | | | VALENTINA BROGLIA | | | ASSOCIATE PLANNER | | | [email protected] | | | |
|
|
|