Plan Review Details - Permit 22020688
Plan Review Stops For Permit 22020688
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-04-12 Cont ID  
Sent By pvalenti Date 2022-04-12 Time 09:06 Rev Time 0.00
Received By pvalenti Date 2022-04-12 Time 09:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-04-08 Cont ID  
Sent By pvalenti Date 2022-04-08 Time 12:54 Rev Time 0.00
Received By pvalenti Date 2022-04-08 Time 11:16 Sent To  
Notes
2022-04-08 13:00:16PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, THE PRODUCT APPROVAL # FOR THE SHUTTERS
 IS FL 1850-R14 BUT THE PRODUCT APPROVAL NUMBER
 INDICATED ON THE SCHEDULE IS FL 389-R10. PLEASE CORRECT
 THE PRODUCT APPROVAL NUMBER INDICATED ON THE SCHEDULE
 TO MATCH THE PRODUCT APPROVAL NUMBER THAT WAS SUBMITTED
 IF THAT REPRESENTS THE PRODUCT TO BE USED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-03-31 Cont ID  
Sent By pvalenti Date 2022-03-31 Time 06:02 Rev Time 0.00
Received By pvalenti Date 2022-03-31 Time 06:01 Sent To  
Notes
2022-03-31 06:03:02PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 THE SHUTTER SCHEDULE IS INCOMPLETE AND CORRECTIONS NEED
 TO BE MADE, SEE BELOW:
  
 1.) COLUMN #3 (PRESSURES) NEEDS TO BE COMPLETED, THE
 TOP SECTION IS FOR POSITIVE AND THE BOTTOM SECTION IS
 FOR NEGATIVE.
 2.) COLUMN #5 (SHUTTER GLASS SEPARATION) ENTER VALUE
 PER PRODUCT APPROVAL.
 3.) COLUMN #6 (SHUTTER SPAN), FOR ACCORDIAN SHUTTER
 SPANS THE SPAN IS TYPICALLY THE HEIGHT FROM TRACK TO
 TRACK. PLEASE CORRECT THIS SPACE.
 4.) COLUMN #7 (SHUTTER ORIENTATION), THIS SHOULD BE
 VERTICAL LIKE THE SPAN.
 5.) COLUMN #11 (SUBSTRATE), THE SUBSTRATE NEEDS TO BE
 IDENTIFIED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-03-16 Cont ID  
Sent By pvalenti Date 2022-03-16 Time 09:48 Rev Time 0.00
Received By pvalenti Date 2022-03-16 Time 09:42 Sent To  
Notes
2022-03-16 09:50:18PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 1. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION
 OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL
 INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL
 SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE
 NOTE FACTORS APPLY DEPENDING ON SUBSTRATE, EDGE
 DISTANCE AND FASTENER. FOR FASTENER, IF USING TAPCON,
 BE SPECIFIC AS TO WHICH TAPCON.
  
 PLEASE CONTACT ME IF YOU NEED ASSISTANCE.
  
 3. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC
 R 310.4; INCLUDE ROOM DESIGNATION.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-03-31 Cont ID  
Sent By pvalenti Date 2022-03-31 Time 06:16 Rev Time 0.00
Received By pvalenti Date 2022-03-31 Time 06:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-03-16 Cont ID  
Sent By pvalenti Date 2022-03-16 Time 09:50 Rev Time 0.00
Received By pvalenti Date 2022-02-14 Time 05:41 Sent To  
Notes
***NONE***