Plan Review Details - Permit 22020687
| Plan Review Stops For Permit 22020687 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-15 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-15 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2022-02-15 11:30:00 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | FOR OPENINGS 3 & 4, IN ADDITION TO THE TOP | | | TRUSSCONNECTIONSAT 24"O.C., CONNECTIONS TO 1/4" FLAT | | | BAR ARE AT 6" O.C. AS PER PRODUCT APPROVAL FL 17080-R3 | | | SHEET 12 OF 13. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-12 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-12 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2022-02-12 08:09:11 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, THE SUBMITTED SCHEDULE APPEARS TO BE | | | INCOMPLETE. FOR OPENINGS 3 AND 4 AN ADDITIONAL NOTE | | | SHOULD BE ADDED. THIS NOTE NEEDS TO CLARIFY THAT IN | | | ADDITION TO THE TOP TRUSS CONNECTIONS AT 24" O.C., | | | CONNECTIONS TO 1/4" FLAT BAR ARE AT 6" O.C. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-12 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-11 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-02-12 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2022-02-12 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2022-02-12 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2022-02-12 07:58:22 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | SIGNATURE REVIEW APPROVED BY SUBMITTED HAND | | | SIGNED/SEALED PAPER WINDLOAD DOCUMENT. |
|
|
|