| Plan Review Stops For Permit 22020626 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-08-15 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-15 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-07 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-07 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2022-03-07 16:03:19 | ANTENNA AND EQUIPMENT | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE SHOW THE WIND DATA USED FOR THE WIND DESIGN | | | FOR THE EQUIPMENT DECK AND ANTENNA MOUNTS ETC.( RISK | | | CATEGORY, EXPOSURE, WIND SPEED - PER 2020 FBC USING | | | ASCE 7-16) PER FBC 1603.1.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-08-15 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-08-15 |
Time |
14:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-03-08 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-03-08 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2022-03-08 09:34:49 | CODES IN EFFECT: | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-3 | | | | | | 1) PANEL HAS A NOTE REQUIRING THE NEUTRAL AND GROUND BE | | | BONDED? | | | | | | 250.24 LOAD-SIDE GROUNDING CONNECTIONS. A GROUNDED | | | CONDUCTOR SHALL NOT BE CONNECTED TO NORMALLY | | | NON?CURRENT-CARRYING | | | METAL PARTS OF EQUIPMENT, TO EQUIPMENT GROUNDING | | | CONDUCTOR(S), OR BE RECONNECTED TO GROUND ON THE LOAD | | | SIDE OF THE | | | SERVICE DISCONNECTING MEANS EXCEPT AS OTHERWISE | | | PERMITTED IN THIS ARTICLE. | | | | | | 2) GROUND ROD SHOWN AT PANEL TO BE BONDED TO SYSTEM | | | GROUNDING ELECTRODE CONDUCTOR SYSTEM AT THE SERVICE. | | | | | | 250.58 COMMON GROUNDING ELECTRODE. WHERE AN AC SYSTEM | | | IS CONNECTED TO A GROUNDING ELECTRODE IN OR AT A | | | BUILDING OR STRUCTURE, | | | THE SAME ELECTRODE SHALL BE USED TO GROUND CONDUCTOR | | | ENCLOSURES AND EQUIPMENT IN OR ON THAT BUILDING OR | | | STRUCTURE. | | | WHERE SEPARATE SERVICES, FEEDERS, OR BRANCH CIRCUITS | | | SUPPLY A BUILDING AND ARE REQUIRED TO BE CONNECTED TO A | | | GROUNDING ELECTRODE( | | | S), THE SAME GROUNDING ELECTRODE(S) SHALL BE USED. TWO | | | OR MORE GROUNDING ELECTRODES THAT ARE BONDED TOGETHER | | | SHALL BE CONSIDERED AS A SINGLE GROUNDING ELECTRODE | | | SYSTEM IN THIS SENSE. | | | | | | 3) FAULT CURRENT CALCULATION REQUIRED FOR THE SERVCE | | | 110.9, 110.10, 110.24(A) | | | | | | 110.24 AVAILABLE FAULT CURRENT. (A) FIELD MARKING. | | | SERVICE EQUIPMENT AT OTHER THAN DWELLING | | | UNITS SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE | | | MAXIMUM AVAILABLE FAULT CURRENT. THE FIELD MARKING(S) | | | SHALL INCLUDE THE | | | DATE THE FAULT-CURRENT CALCULATION WAS PERFORMED AND BE | | | OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT | | | INVOLVED. | | | THE CALCULATION SHALL BE DOCUMENTED AND MADE AVAILABLE | | | TO THOSE AUTHORIZED TO DESIGN, INSTALL, INSPECT, | | | MAINTAIN, OR OPERATE | | | THE SYSTEM. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-08-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2022-08-09 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2022-08-09 07:05:41 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-02-15 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-02-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2022-02-15 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2022-02-15 12:09:50 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-08-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-08-15 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-08-03 |
Time |
13:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2022-03-28 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2022-02-11 |
Time |
05:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-08-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2022-08-03 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2022-08-03 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2022-08-03 17:11:07 | SIGNED AND SEALED CALCULATIONS ON PAPER SENT TO | | | STORAGE. RM |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-07 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-07 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-10-27 |
Time |
16:36 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-10-27 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-08-04 |
Time |
15:46 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-08-04 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2022-08-04 15:46:53 | FAILED | | | | | | REPEAT COMMENT: THE MODIFICATION TO THE EXISTING TOWER | | | REQUIRES THE APPROVAL OF A CITY WIRELESS COMMUNICATION | | | FACILITY APPLICATION. PLEASE CONTACT THE PLANNING | | | DIVISION AT THE CONTACT INFORMATION BELOW FOR A COPY OF | | | THE APPLICATION. | | | | | | ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-03-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2022-03-28 |
Time |
09:22 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2022-03-28 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2022-03-28 09:41:57 | FAILED | | | | | | THE MODIFICATION TO THE EXISTING TOWER REQUIRES THE | | | APPROVAL OF A CITY WIRELESS COMMUNICATION FACILITY | | | APPLICATION. PLEASE CONTACT THE PLANNING DIVISION AT | | | THE CONTACT INFORMATION BELOW FOR A COPY OF THE | | | APPLICATION. | | | | | | ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] |
|
|