| 2022-05-04 15:01:01 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) RESOLVED. CIRCLE OR HI-LITE THE MODEL AND THE WIND |
| | PRESSURES OF THE 22" TCC SKYLIGHT LISTED IN THE PRODUCT |
| | APPROVAL THAT WILL BE INSTALLED. FBC AMENDMENTS 107.2.1 |
| | |
| | 2) NOT RESOLVED [ THE WIND SPEED IS 170 MPH VULT. NOT |
| | -54. ] SPECIFY THE WIND DATA (WINDSPEED, EXPOSURE |
| | CATEGORY, MEAN ROOF HEIGHT) ON THE DRAWING. |
| | FBC-R301.2.1 |
| | |
| | 3) NOT RESOLVED. [ THE -54.0 THAT IS CIRCLED IN THE |
| | SIMPLIFIED UPLIFT CHART IS COMPONENT AND CLADDING |
| | PRESSURE FOR A HIP ROOF WITH A SLOPE BETWEEN 4:12 AND |
| | 6:12 FOR ROOF ZONE 1. THE ISSUES THAT I HAVE ARE THAT |
| | THE EXPOSURE CATEGORY C IS NOT SPECIFIED FOR THIS TABLE |
| | AND THE PRODUCT APPROVAL HAS A DESIGN PRESSURE OF +/- |
| | 50 PSF FOR THE IMPACT RATED SKYLIGHT WHICH IS LESS THAN |
| | -54 PSF.] SPECIFY THE TYPE OF ROOF (GABLE OR HIP), THE |
| | ROOFING MATERIAL, THE ROOF SLOPE AND THE ROOF COMPONENT |
| | AND CLADDING PRESSURE ZONE FOR THE SKYLIGHT |
| | INSTALLATION. THE DESIGN PRESSURES FOR THE SKYLIGHT |
| | ASSEMBLY HAVE TO BE GREATER THAN THE REQUIRED |
| | PRESSURES. FBC-R301 |
| | |
| | 4) RESOLVED.PROVIDE A CLEAR AND DETAILED ROOF DIAGRAM |
| | THAT SHOWS THE PROPOSED LOCATION OF THE SKYLIGHT. THE |
| | ONE THAT WAS SUBMITTED IS NOT CLEAR OR DETAILED ENOUGH. |
| | FBC 107.2.1 |
| | |
| | 5) NOT RESOLVED. [ IT IS NOT CLEAR HOW THE CURB WILL BE |
| | ATTACHED TO THE ROOF. IS IT JUST SCREWED TO THE PLYWOOD |
| | SHEATHING OR WILL IT ATTACH TO FRAMING UNDER THE |
| | SHEATHING? BASED ON THE INSTALLATION INSTRUCTIONS |
| | FRAMING IS REQUIRED. SPECIFY THE NUMBER AND LOCATIONS |
| | OF THE SCREWS THAT WILL ATTACH THE CURB TO THE ROOF? |
| | WHAT MATERIAL WILL BE USED TO BUILD THE CURB? PROVIDE A |
| | DETAILED DRAWING SIGNED AND SEALED BY A FLORIDA |
| | LICENSED ARCHITECT OR ENGINEER. THE NEXT TWO SENTANCES |
| | ARE FROM THE INSTALLATION INSTRUCTIONS: BUILD CURB |
| | ACCORDING TO MEASUREMENTS IN THE CHART. CURB HEIGHT AND |
| | ATTACHMENT SHOULD COMPLY WITH BUILDING CODES AND |
| | REGULATIONS AND BE SECURE ENOUGH TO TRANSFER THE SUN |
| | TUNNEL LOADS TO THE FRAMING MEMBERS.] IF YOU ARE USING |
| | A CURB TO RAISE THE SKYLIGHT ABOVE A CONCRETE TILE |
| | ROOF, PROVIDE A DETAIL FOR HOW THE CURB FRAMING WILL BE |
| | SUPPORTED AND ANCHORED TO THE ROOF. FBC-R301 |
| | |
| | 6) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH |
| | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
| | |
| | |
| | |
| | |