| 2022-04-01 11:26:14 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #22020357 |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | NOTE: |
| | ADDITIONS SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 |
| | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, |
| | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE |
| | REQUIREMENTS OF THE FLORIDA BUILDING CODE. |
| | |
| | NOTE: |
| | LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING BUILDING. |
| | SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION |
| | ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY |
| | WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. |
| | |
| | 1-LOT DRAINAGE: PROPOSED ADDITION (AND POOL) AFFECTS |
| | THE LOT DRAINAGE. PROVIDE DRAINAGE PLAN SHOWING HOW THE |
| | SURFACE DRAINAGE IS KEPT WITHIN THE LOT AND NOT |
| | DIVERTED TO ADJACENT PROPERTIES. PROVIDE DRAINAGE PLAN |
| | SHOWING COMPLIANCE WITH THE FOLLOWING SECTIONS: R401.3 |
| | FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS AND SEC. |
| | 110.9 CITY AMENDMENTS. |
| | NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED |
| | GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM |
| | ADJACENT PROPERTIES. |
| | |
| | 2-PRODUCT APPROVALS |
| | 12-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| | 61G20-3.001 FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW |
| | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL |
| | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL): |
| | |
| | A)EXTERIOR DOORS. |
| | B)WINDOWS. |
| | C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE |
| | TO AVOID DELAYS/CONFLICTS). |
| | D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION |
| | SCHEDULE. SEE CITY SAMPLE. |
| | E)METAL ROOF. |
| | F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS FOR METAL |
| | ROOFING. |
| | G)SLEEPING PORCH UNDERLAYMENT FOR CERAMIC TILE AS |
| | SPECIFIED ON PLANS. |
| | |
| | 3- WINDOW FALL PROTECTION SHALL BE PROVIDED ON SECOND |
| | FLOOR WINDOWS WHERE THE TOP OF THE WINDOW SILL OF AN |
| | OPERABLE WINDOW IS LOCATED LESS THAN 24" ABOVE THE |
| | FINISHED FLOOR . SEC. R312.2 FBC RESIDENTIAL. |
| | NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND |
| | FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL |
| | PROTECTION IF REQUIRED. |
| | |
| | 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | ALUMINUM TRELLIS CONSTRUCTION. SPECIFY ALL FRAMING |
| | MEMBERS AND CONNECTOR AT EACH END. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 5- DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON THE |
| | EXTERIOR ELEVATIONS DON'T MATCH DESIGN PRESSURES |
| | SPECIFIED BY THE ENGINEER OF RECORD ON SHEET S1. REVISE |
| | AS REQUIRED. SEC. R301.2.1 FBC-RESIDENTIAL. |
| | NOTE: COORDINATE WITH ITEM #6 BELOW. |
| | |
| | 6- ENGINEER OF RECORD TO REVISE END ZONE DIMENSION |
| | SPECIFIED UNDER WIND DESIGN CRITERIA ON SHEET S1. THE |
| | MINIMUM DIMENSION IS 4'-0" NOT 3'-0" AS REQUIRED BY |
| | NOTE "A" ON FIGURE R301.2(7) FBC-RESIDENTIAL. REVISE AS |
| | REQUIRED. |
| | |
| | 7- ENGINEER OF RECORD TO PROVIDE SPECIFICATIONS FOR THE |
| | CONCRETE SLAB VAPOR BARRIER AS REQUIRED BY SEC. |
| | R506.2.3 FBC-RESIDENTIAL. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE |
| | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |