Plan Review Details - Permit 22020357
Plan Review Stops For Permit 22020357
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-04-04 Cont ID  
Sent By jgomez Date 2022-04-04 Time 12:54 Rev Time 0.00
Received By jgomez Date 2022-04-04 Time 11:07 Sent To  
Notes
2022-04-04 12:54:44BUILDING REVIEW APPROVED WITH PROVISO:
 (NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO
 CONSTRUCTION TO AVOID CONFLICTS/DELAYS):
 1- PROVIDE LOT DRAINAGE PLAN: NOTE: SHOW EXISTING AND
 PROPOSED GRADE ELEVATIONS SHOWING HOW KEEPING WATER
 AWAY FROM ADJACENT PROPERTIES.
 2-PROVIDE PRODUCT APPROVALS APPROVED BY ENGINEER OF
 RECORD FOR: A)EXTERIOR DOORS. B)WINDOWS. C)WINDOW
 MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE).
 D)HURRICANE SHUTTERS IF DOORS/WINDOWS DON'T HAVE IMPACT
 GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
 SEE CITY SAMPLE. E)METAL ROOF. F)ROOFING UNDERLAYMENT
 SPECIFIED ON PLANS FOR METAL ROOFING. G)SLEEPING PORCH
 UNDERLAYMENT FOR CERAMIC TILE AS SPECIFIED ON PLANS.
 3- WINDOW FALL PROTECTION SHALL BE PROVIDED ON SECOND
 FLOOR WINDOWS WHERE THE TOP OF THE WINDOW SILL OF AN
 OPERABLE WINDOW IS LOCATED LESS THAN 24" ABOVE THE
 FINISHED FLOOR . SEC. R312.2 FBC RESIDENTIAL.
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 ALUMINUM TRELLIS CONSTRUCTION. SPECIFY ALL FRAMING
 MEMBERS AND CONNECTOR AT EACH END.
 5- REVISE DOORS/WINDOWS DESIGN PRESSURES SHOWN ON THE
 EXTERIOR ELEVATIONS TO MATCH DESIGN PRESSURES SPECIFIED
 ON SHEET S1.
 6- ENGINEER OF RECORD TO REVISE END ZONE DIMENSION
 SPECIFIED UNDER WIND DESIGN CRITERIA ON SHEET S1. THE
 MINIMUM DIMENSION IS 4'-0" NOT 3'-0" AS REQUIRED BY
 NOTE "A" ON FIGURE R301.2(7) FBC-RESIDENTIAL.
 7- ENGINEER OF RECORD TO PROVIDE SPECIFICATIONS FOR THE
 CONCRETE SLAB VAPOR BARRIER AS REQUIRED BY SEC.
 R506.2.3 FBC-RESIDENTIAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-04-01 Cont ID  
Sent By jgomez Date 2022-04-01 Time 11:25 Rev Time 0.00
Received By jgomez Date 2022-03-31 Time 15:15 Sent To  
Notes
2022-04-01 11:26:14RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22020357
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO
 MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER
 THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID
 CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR
 TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME
 OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT
 ISSUANCE.
  
 NOTE:
 ADDITIONS SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 NOTE:
 LEVEL 2 ALTERATION. SEC. 603 FBC-EXISTING BUILDING.
 SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION
 ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY
 WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1-LOT DRAINAGE: PROPOSED ADDITION (AND POOL) AFFECTS
 THE LOT DRAINAGE. PROVIDE DRAINAGE PLAN SHOWING HOW THE
 SURFACE DRAINAGE IS KEPT WITHIN THE LOT AND NOT
 DIVERTED TO ADJACENT PROPERTIES. PROVIDE DRAINAGE PLAN
 SHOWING COMPLIANCE WITH THE FOLLOWING SECTIONS: R401.3
 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS AND SEC.
 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 2-PRODUCT APPROVALS
 12-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC
 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)EXTERIOR DOORS.
 B)WINDOWS.
 C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO AVOID DELAYS/CONFLICTS).
 D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)METAL ROOF.
 F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS FOR METAL
 ROOFING.
 G)SLEEPING PORCH UNDERLAYMENT FOR CERAMIC TILE AS
 SPECIFIED ON PLANS.
  
 3- WINDOW FALL PROTECTION SHALL BE PROVIDED ON SECOND
 FLOOR WINDOWS WHERE THE TOP OF THE WINDOW SILL OF AN
 OPERABLE WINDOW IS LOCATED LESS THAN 24" ABOVE THE
 FINISHED FLOOR . SEC. R312.2 FBC RESIDENTIAL.
 NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND
 FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL
 PROTECTION IF REQUIRED.
  
 4- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 ALUMINUM TRELLIS CONSTRUCTION. SPECIFY ALL FRAMING
 MEMBERS AND CONNECTOR AT EACH END. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 5- DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON THE
 EXTERIOR ELEVATIONS DON'T MATCH DESIGN PRESSURES
 SPECIFIED BY THE ENGINEER OF RECORD ON SHEET S1. REVISE
 AS REQUIRED. SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: COORDINATE WITH ITEM #6 BELOW.
  
 6- ENGINEER OF RECORD TO REVISE END ZONE DIMENSION
 SPECIFIED UNDER WIND DESIGN CRITERIA ON SHEET S1. THE
 MINIMUM DIMENSION IS 4'-0" NOT 3'-0" AS REQUIRED BY
 NOTE "A" ON FIGURE R301.2(7) FBC-RESIDENTIAL. REVISE AS
 REQUIRED.
  
 7- ENGINEER OF RECORD TO PROVIDE SPECIFICATIONS FOR THE
 CONCRETE SLAB VAPOR BARRIER AS REQUIRED BY SEC.
 R506.2.3 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-02-28 Cont ID  
Sent By mpeterso Date 2022-02-28 Time 16:32 Rev Time 0.00
Received By mpeterso Date 2022-02-28 Time 16:32 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By amhamilt Date 2022-02-24 Time 16:30 Rev Time 0.00
Received By amhamilt Date 2022-02-24 Time 16:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-04-04 Cont ID  
Sent By jgomez Date 2022-04-04 Time 13:00 Rev Time 0.00
Received By jgomez Date 2022-04-04 Time 11:07 Sent To I
Notes
2022-04-04 11:22:174-1-22 EMAIL.
 THANK YOU, MR GOMEZ. YES, IT IS PERFECTLY ACCEPTABLE TO
 US TO FALL IN LINE IMMEDIATELY WITH THE PROVISOS AFTER
 ISSUANCE OF THE PERMIT. PLEASE NOTE, WE DO NOT WISH TO
 INCLUDE THE POOL IN CONSIDERATION OF THIS APPLICATION
 FOR PERMIT.
  
 GERALD MEITZ JR
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-01 Cont ID  
Sent By jgomez Date 2022-04-01 Time 13:55 Rev Time 0.00
Received By jgomez Date 2022-02-07 Time 16:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-04-19 Cont ID  
Sent By aoliver Date 2022-04-19 Time 10:51 Rev Time 0.00
Received By aoliver Date 2022-04-08 Time 08:28 Sent To  
Notes
2022-04-19 08:27:59RECEIPT MU-2022-016094 - $546.52 PAID
2022-04-08 08:30:044/8/22 EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-04-01 Cont ID  
Sent By jgomez Date 2022-04-01 Time 13:53 Rev Time 0.00
Received By jgomez Date 2022-04-01 Time 13:52 Sent To  
Notes
2022-04-01 13:53:26IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-02-23 Cont ID  
Sent By medwards Date 2022-02-23 Time 08:25 Rev Time 0.00
Received By medwards Date 2022-02-23 Time 08:25 Sent To  
Notes
2022-02-23 08:27:34APPROVED WITH PRIVISO:
 THE HOOD EXHAUST SHALL MEET MAKE UP AIR REQUIREMENTS OF
 FBC RES M1503.4
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-02-12 Cont ID  
Sent By abelisle Date 2022-02-12 Time 16:24 Rev Time 0.00
Received By abelisle Date 2022-02-12 Time 15:23 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2022-04-04 Cont ID  
Sent By jgomez Date 2022-04-04 Time 13:17 Rev Time 0.00
Received By jgomez Date 2022-04-04 Time 13:16 Sent To  
Notes
2022-04-04 13:21:001- NEED TO PROVIDE ROOFING INFORMATION FOR REVIEW
 BEFORE ISSUING ROOFING SUB-PERMIT. JG.
  
 1-PRODUCT APPROVALS DEFERRED SUBMITTAL:
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: PROVIDE COMPLETE INFORMATION FOR REVIEW PRIOR TO
 INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT
 APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF
 RECORD PRIOR TO SUBMITTAL):
  
 A) METAL ROOF.
 B) ROOFING UNDERLAYMENT SPECIFIED ON PLANS FOR METAL
 ROOFING.
 C) SLEEPING PORCH UNDERLAYMENT FOR CERAMIC TILE AS
 SPECIFIED ON PLANS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-04-01 Cont ID  
Sent By jgomez Date 2022-04-01 Time 13:54 Rev Time 0.00
Received By jgomez Date 2022-04-01 Time 13:53 Sent To  
Notes
2022-04-01 13:55:51ROOFING REVIEW:
  
 1-PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A) METAL ROOF.
 B) ROOFING UNDERLAYMENT SPECIFIED ON PLANS FOR METAL
 ROOFING.
 C) SLEEPING PORCH UNDERLAYMENT FOR CERAMIC TILE AS
 SPECIFIED ON PLANS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-02-09 Cont ID  
Sent By medwards Date 2022-02-09 Time 06:29 Rev Time 0.00
Received By medwards Date 2022-02-09 Time 06:29 Sent To  
Notes
2022-02-09 06:30:38ROUTED ORIGINAL PAPER DRAWINGS TO STORAGE.ME

Review Stop Z ZONING
Rev No 1 Status P Date 2022-02-24 Cont ID  
Sent By vbroglia Date 2022-02-24 Time 16:30 Rev Time 0.00
Received By amhamilt Date 2022-02-24 Time 16:30 Sent To  
Notes
***NONE***