| Plan Review Stops For Permit 22020215 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-21 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-21 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2022-07-21 06:36:58 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 2ND REVIEW, PREVIOUS REVIEW NOT ADDRESSED: | | | | | | 1. FBC B 1609, FS471, ENGINEERING IS REQUIRED FOR | | | SIGNS. THE PLAN SUBMITTED IS NOT DESIGNED BY AN | | | ENGINEER AND DOES NOT INCLUDE WIND DESIGN CRITERIA. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-05-14 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-14 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2022-05-14 11:27:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC B 1609, FS471, ENGINEERING IS REQUIRED FOR | | | SIGNS. THE PLAN SUBMITTED IS NOT DESIGNED BY AN | | | ENGINEER AND DOES NOT INCLUDE WIND DESIGN CRITERIA. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2022-07-08 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-07-08 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-07-08 |
Time |
18:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-06-02 |
Time |
00:06 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-06-01 |
Time |
22:56 |
Sent To |
|
|
| Notes |
| 2022-06-02 00:06:15 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE | | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | FRANK GIAQUINTO III | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | [email protected] | | | CELL: 561-805-6744 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-21 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-06-23 |
Time |
09:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-06-02 |
|
|
Cont ID |
|
| Sent By |
fgiaquin |
Date |
2022-06-02 |
Time |
00:06 |
Rev Time |
0.00 |
| Received By |
fgiaquin |
Date |
2022-05-11 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-07-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-07-21 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-07-21 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2022-07-21 06:37:15 | SEE BUILDING COMMENTS |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2022-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-05-14 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-05-14 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2022-05-14 11:27:30 | SEE BUILDING COMMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2022-06-30 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-06-30 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-06-30 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2022-05-13 |
|
|
Cont ID |
|
| Sent By |
afowlkes |
Date |
2022-05-13 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
afowlkes |
Date |
2022-05-13 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2022-05-13 14:26:23 | 05/13/22 FAILED - THIS SIGN GREATLY EXCEEDS THE MAXIMUM | | | SQ FOOTAGE ALLOWANCE. BECAUSE THIS PROPERTY FALLS | | | WITHIN THE HAVERHILL COMMERCE CENTER INDUSTRIAL PLANNED | | | DEVELOPMENT, THE DESIGN GUIDELINES ARE GOVERNED BY | | | ORDINANCE NO. 3198-98. PLEASE REACH OUT TO ME VIA | | | E-MAIL AND I CAN SEND YOU A COPY OF THIS ORDINACE SO | | | YOU CAN ADJUST YOUR SIGN PLAN ACCORDINGLY. | | | | | | ALEXANDER FOWLKES | | | 5618221431 | | | [email protected] |
|
|