Plan Review Details - Permit 22020213
Plan Review Stops For Permit 22020213
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-06-07 Cont ID  
Sent By rmcphers Date 2022-06-07 Time 17:03 Rev Time 0.00
Received By rmcphers Date 2022-06-07 Time 17:02 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-05-04 Cont ID  
Sent By rmcphers Date 2022-05-04 Time 11:33 Rev Time 0.00
Received By rmcphers Date 2022-05-04 Time 09:42 Sent To  
Notes
2022-05-04 11:33:40PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-10-04 Cont ID  
Sent By rmcphers Date 2022-10-04 Time 11:28 Rev Time 0.00
Received By rmcphers Date 2022-10-04 Time 11:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-07 Cont ID  
Sent By rmcphers Date 2022-06-07 Time 16:59 Rev Time 0.00
Received By rmcphers Date 2022-06-07 Time 16:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-04 Cont ID  
Sent By rmcphers Date 2022-05-04 Time 11:33 Rev Time 0.00
Received By rmcphers Date 2022-05-04 Time 09:42 Sent To  
Notes
2022-05-04 11:44:44REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ACCESSIBLE RESTROOM - PLEASE SHOW THE MAXIMUM HEIGHT
 OF THE TOILET GRAB BARS TO BE TO THE TOP OF THE
 "GRIPPING SURFACE" NOT TO THE CENTER OF THE BAR AS
 SHOWN ON THE DRAWINGS - PER FBC A 609.4 POSITION OF
 GRAB BARS.
  
 2) PLEASE PROVIDE THE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE ROOFING SYSTEM - OR - STATE ON
 THE DRAWNGS THAT THE ROOFING IS TO BE UNDER A SEPARATE
 PERMIT.
  
 3) ROOFING SYSTEMS MAY BE DEFERRED SUBMITTALS BY
 LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION
 DOCUMENTS - 107.3.4.1 DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE,
  
 4) A SEPARATE PERMIT IS REQUIRED FOR THE DUMPSTER
 ENCLOSURE - PLEASE ACKNOWLEDGE THIS.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2022-10-13 Cont ID  
Sent By mpeterso Date 2022-10-13 Time 09:37 Rev Time 0.00
Received By mpeterso Date 2022-10-13 Time 09:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2022-08-09 Cont ID  
Sent By mpeterso Date 2022-08-09 Time 08:11 Rev Time 0.00
Received By mpeterso Date 2022-08-09 Time 08:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-03 Cont ID  
Sent By mpeterso Date 2022-06-03 Time 13:23 Rev Time 0.00
Received By mpeterso Date 2022-06-03 Time 13:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-03 Cont ID  
Sent By mpeterso Date 2022-05-03 Time 13:11 Rev Time 0.00
Received By mpeterso Date 2022-05-03 Time 13:11 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-01-06 Cont ID  
Sent By jleahy Date 2023-01-06 Time 10:22 Rev Time 0.00
Received By jleahy Date 2023-01-06 Time 10:22 Sent To  
Notes
2023-01-06 10:22:43VOICE , DATA, TV JLEAHY

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2022-06-07 Cont ID  
Sent By rrossano Date 2022-06-07 Time   Rev Time 0.00
Received By rrossano Date 2022-06-07 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-07-26 Cont ID  
Sent By   Date 2022-07-26 Time   Rev Time 0.00
Received By bdolan Date 2022-07-26 Time 10:38 Sent To  
Notes
2022-07-26 10:38:28THIS PLAN WAS REVIEWED AND APPROVED BY LT. BRIAN DOLAN,
 DIVISION OF FIRE PREVENTION, WITH THE FOLLOWING
 COMMENT:
  
 ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 EXISTING FIRE ALARM SYSTEMS (IF PRESENT) FOR CODE
 COVERAGE AND COMPLIANCE BY CERTIFIED CONTRACTORS. ANY
 WORK MUST BE SUBMITTED UNDER A SEPERATE PERMIT.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-05-23 Cont ID  
Sent By   Date 2022-05-23 Time   Rev Time 0.00
Received By bdolan Date 2022-05-23 Time 12:02 Sent To  
Notes
2022-05-23 12:02:44THIS PLAN WAS REVIEWED AND APPROVED BY LT. BRIAN DOLAN,
 DIVISION OF FIRE PREVENTION, WITH THE FOLLOWING
 COMMENT:
  
 ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 EXISTING FIRE ALARM SYSTEMS (IF PRESENT) FOR CODE
 COVERAGE AND COMPLIANCE BY CERTIFIED CONTRACTORS. ANY
 WORK MUST BE SUBMITTED UNDER A SEPERATE PERMIT.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-03-31 Cont ID  
Sent By   Date 2022-03-31 Time   Rev Time 0.00
Received By bdolan Date 2022-03-31 Time 14:31 Sent To  
Notes
2022-03-31 14:03:00THIS PLAN WAS REVIEWED AND APPROVED BY LT. BRIAN DOLAN,
 DIVISION OF FIRE PREVENTION, WITH THE FOLLOWING
 COMMENT:
  
 ANY REMOVAL AND/OR CONSTRUCTION OF THE CEILING/WALL
 AREAS MAY REQUIRE AN EVALUATION OR MODIFICATION OF THE
 EXISTING FIRE ALARM SYSTEMS (IF PRESENT) FOR CODE
 COVERAGE AND COMPLIANCE BY CERTIFIED CONTRACTORS. ANY
 WORK MUST BE SUBMITTED UNDER A SEPERATE PERMIT.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-10-13 Cont ID  
Sent By mpeterso Date 2022-10-13 Time 09:37 Rev Time 0.00
Received By mpeterso Date 2022-09-16 Time 09:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-08-09 Cont ID  
Sent By asangele Date 2022-08-09 Time 09:22 Rev Time 0.00
Received By asangele Date 2022-08-09 Time 09:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-10 Cont ID  
Sent By asangele Date 2022-06-10 Time   Rev Time 0.00
Received By asangele Date 2022-05-22 Time 15:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-12 Cont ID  
Sent By rmcphers Date 2022-05-12 Time 09:21 Rev Time 0.00
Received By asangele Date 2022-05-12 Time 09:21 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-05-04 Cont ID  
Sent By rmcphers Date 2022-05-04 Time 11:44 Rev Time 0.00
Received By rmcphers Date 2022-05-04 Time 11:44 Sent To  
Notes
2022-05-04 11:45:28NO CHANGE OF OCCUPANCY CLASSIFICATION - NO ADDED SQUARE
 FOOTAGE

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2022-10-04 Cont ID  
Sent By medwards Date 2022-09-22 Time 14:46 Rev Time 0.00
Received By medwards Date 2022-10-04 Time 09:10 Sent To  
Notes
2022-10-04 09:14:36APPROVED WITH PRIVISO:
 PLEASE PROVIDE A REVISION BEFORE 1ST MECHANICAL
 INSPECTION SHOWING THE NEW LOCATION FOR THE EF-4 WILL
 MEET THE CLEARANCES FROM THE DOOR ACCORDING TO FMC
 501.3.1 NUMBER 1 OR SHOW THAT THIS EXHAUST IS NOT
 EXPLOSIVE OR FLAMMABLE VAPORS, FUMES.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-07-28 Cont ID  
Sent By medwards Date 2022-07-28 Time 10:38 Rev Time 0.00
Received By medwards Date 2022-07-28 Time 10:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-01 Cont ID  
Sent By medwards Date 2022-06-01 Time 07:46 Rev Time 0.00
Received By medwards Date 2022-06-01 Time 07:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-04-26 Cont ID  
Sent By medwards Date 2022-04-26 Time 14:21 Rev Time 0.00
Received By medwards Date 2022-04-26 Time 14:21 Sent To  
Notes
2022-04-26 14:21:301ST REVIEW FMC
 PERMIT: 22020213
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS FOR THE NEW SYSTEMS. FMC 312.1
  
 2) PLEASE ADD THE DUCT SIZES TO ALL DUCTS LEADING TO
 THE SUPPLY AND RETURN GRILLES. FBC 107.2.1
  
 3) SHEET M101 FOOT NOTE 6 CALLS FOR A 1 HOUR FIRE DUCT
 WRAP. PLEASE PROVIDE A DETAIL OF THIS FIRE RATED DUCT
 WRAP WITH THIS DESIGN. DOES THE WRAP INCLUDE THE EF-4
 EXHAUST FAN? DOES THE 1 HOUR DUCT FIRE WRAP CONTINUE TO
 THE EXHAUST DUCT TERMINATION LOCATION? FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop MEDGAS MEDICAL GAS
Rev No 4 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 09:48 Rev Time 0.00
Received By ccole Date 2022-10-03 Time 09:45 Sent To  
Notes
2022-10-04 09:49:30SUB-PERMIT REQUIRED.
 SEE MECHANICAL PROVISO FOR MED-GAS EXHAUST FAN.

Review Stop MEDGAS MEDICAL GAS
Rev No 3 Status F Date 2022-08-02 Cont ID  
Sent By ccole Date 2022-08-02 Time 12:15 Rev Time 0.00
Received By ccole Date 2022-08-01 Time 11:25 Sent To  
Notes
2022-08-02 12:15:453RD REVIEW FBC-2020 PLUMBING/ MED-GAS
 PERMIT- 22020213
 8/2/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 NFPA-99-2018
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST AND 2ND ARE LISTED BELOW WITH ADDITIONAL NOTES.
 PLEASE REVIEW THE COMMENTS BELOW AND NOTE THAT
 INSTALLATION OF THE MED GAS SYSTEM MAY BE DONE UNDER A
 SEPARATE PERMIT.
  
 2) FAILED: LABEL THE GAS CYLINDERS IN DETAIL 10/P501 AS
 EITHER O2 OR N2O. INDICATE THE CU. FT. CAPACITIES OF
 THE CYLINDERS AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 SECS. 15.3.3.1.1 & 5.1.3.1.1 NFPA 99. THE CYLINDERS
 SHALL BE DESIGNED, FABRICATED, TESTED AND STAMPED IN
 ACCORDANCE WITH REGULATIONS OF DOT, TRANSPORT CANADA
 (TC) TRANSPORTATION OF DANGEROUS GOODS REGULATIONS, OR
 THE ASME BOILER AND PRESSURE VESSEL CODE. REQUESTED
 TANK SPECS NOT PROVIDED.
  
 8) FAILED.: INDICATE HOW MAKEUP AIR FOR THE EXHAUST
 WILL BE PROVIDED- SECS. 15.3.2.1, 5.1.3.3.3.1 &
 9.3.6.5.3.7 NFPA 99. THE M101 PLAN DOES NOT
 SPECIFICALLY SHOW HOW MAKEUP AIR FOR THE EXHAUST IS
 BEING PROVIDED. PLEASE REFER TO SEC. 9.3.6.5.3.7 ITEMS
 1, 2, & 3) NFPA 99- A NON-COMBUSTIBLE DUCT CAN BE USED
 TO TRANSFER AIR FROM ADJACENT SPACES OF FROM THE
 OUTSIDE. PLEASE NOTE THE ARCHITECTURAL PLANS INDICATE
 THE ROOM AND DOOR ARE FIRE-RATED AND SMOKE SEALED. 8A)
 SHEET M101 SHOWS AN IN-LINE EXHAUST FAN INSTALLED IN
 THE 2- HR. FIRE-WRAPPED DUCT, HOWEVER THE FIRE-RATED
 ENCLOSURE OR SHAFT IS REQUIRED TO BE CONTINUOUS FROM
 THE GAS ROOM TO THE EXTERIOR OF THE BUILDING- SECS.
 502.9.1 & 510.7.3 FBC M. PLEASE CLARIFY IF THE FAN WILL
 BE HOUSED IN A 2-HR FIRE-RATED ENCLOSURE WITH SERVICE
 ACCESS, OR WILL SOME OTHER MEANS BE PROVIDED TO
 MAINTAIN THE CONTINUITY OF THE SHAFT.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 CCOLE
  

Review Stop MEDGAS MEDICAL GAS
Rev No 2 Status F Date 2022-06-08 Cont ID  
Sent By ccole Date 2022-06-08 Time 11:03 Rev Time 0.00
Received By ccole Date 2022-06-07 Time 08:37 Sent To  
Notes
2022-06-08 11:04:392ND REVIEW FBC-2020 PLUMBING/ MED-GAS
 PERMIT- 22020213
 6/8/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 NFPA-99-2018
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS ARE LISTED
 BELOW WITH ADDITIONAL NOTES. PLEASE REVIEW THE COMMENTS
 BELOW AND NOTE THAT INSTALLATION OF THE MED GAS SYSTEM
 MAY BE DONE UNDER A SEPARATE PERMIT.
  
 2) FAILED. REQUESTED TANK SPECS NOT PROVIDED.P103 &
 P501: LABEL THE GAS CYLINDERS IN DETAIL 10/P501 AS
 EITHER O2 OR N2O. INDICATE THE CU. FT. CAPACITIES OF
 THE CYLINDERS AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 SECS. 15.3.3.1.1 & 5.1.3.1.1 NFPA 99. THE CYLINDERS
 SHALL BE DESIGNED, FABRICATED, TESTED AND STAMPED IN
 ACCORDANCE WITH REGULATIONS OF DOT, TRANSPORT CANADA
 (TC) TRANSPORTATION OF DANGEROUS GOODS REGULATIONS, OR
 THE ASME BOILER AND PRESSURE VESSEL CODE.
  
 5) FAILED. TANK SPECS WERE NOT SUBMITTED, HOWEVER THE
 NITROUS MANIFOLD SUBMITTAL DOCUMENT INDICATES RELIEF
 VALVES ARE TO BE INSTALLED. NO INFORMATION PROVIDED TO
 VERIFY WHETHER THE TANKS ARE EQUIPPED WITH RELIEF
 VALVES AND IF VENTING IS APPLICABLE. P103 & P501: FOR
 CYLINDERS EQUIPPED WITH RELIEF VALVES PLEASE PROVIDE
 VALVE VENTING DETAILS- SECS. 15.3.2.1 & 5.1.3.5.6.1
 NFPA 99. INCLUDE THE TYPES AND SIZES OF VENT PIPING,
 PIPING RUNS AND DISCHARGE LOCATIONS.
  
 8) FAILED. THE M101 PLAN DOES NOT SPECIFICALLY SHOW HOW
 MAKEUP AIR FOR THE EXHAUST IS BEING PROVIDED. P103 &
 P501: INDICATE HOW MAKEUP AIR FOR THE EXHAUST WILL BE
 PROVIDED- SECS. 15.3.2.1, 5.1.3.3.3.1 & 9.3.6.5.3.7
 NFPA 99.
  
 9) FAILED. THE NITROUS MANIFOLD SUBMITTAL IS NOT FOR
 CONSTRUCTION HOWEVER IT DOES PROVIDE BURST PRESSURE
 LIMITATION FOR FLEX PIPING OTHER THAN METAL. P103 &
 P501 DETAIL 10/P510: LABEL THE TYPES AND SIZES OF
 FLEXIBLE SUPPLY CONNECTORS FROM THE TANK TO THE
 MANIFOLD- SEC. 5.1.10.11.6.1 NFPA 99 B) SHOW SHUTOFF
 VALVE, RELIEF VALVE AND CHECK VALVE LOCATIONS- SEC.
 5.1.4.1.1 NFPA 99.
  
 10) FAILED. LISTED PRESSURE REGULATORS, VALVES, AND
 FLEX CONNECTOR SPECIFICATIONS NOT PROVIDED. P103 &
 P501: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR ALL
 EQUIPMENT AND PIPING IN THE GAS ROOM INCLUDING THE
 MANIFOLD, ALARM SYSTEM, PIPING, REGULATORS, VALVES, AND
 FLEX HOSES- SECS. 15.3.2.1.4, 15.3.2.1.6, 15.3.2.11
 NFPA 99. SHOW THE LOCATIONS OF RELIEF VALVES AND
 PROVIDE RELIEF VALVE VENTING DETAILS INCLUDING TYPE OF
 VENT PIPING, VENT PIPING RUN AND DISCHARGE LOCATION-
 SEC. 15.3.2.11 NFPA 99.
  
 11) FAILED. NOT PROVIDED. P103 & P501: PROVIDE 02, N20
 PIPING SPECIFICATIONS AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS- SECS. 15.3.2.8, 5.1.10.1- 5.1.10.1.8
 NFPA 99. A) INDICATE THE TYPE OF FITTINGS OR TECHNIQUES
 TO BE USED FOR PIPING TURNS, OFFSETS, AND OTHER CHANGES
 IN DIRECTION- SEC. 5.1.10.3.1 ITEMS 1-5 NFPA 99. B)
 PROVIDE PIPE SUPPORT AND HANGING DETAILS- SEC.
 5.1.10.11.4 NFPA 99. C) PROVIDE PIPE LABELING DETAILS-
 SE. 5.1.11.1.1 NFPA 99.
  
 12) FAILED. PLEASE PROVIDE EITHEER SPECIFIC LOCATIONS
 ON THE PLAN OR A GENERAL NOTE. P103: PROVIDE NOTES OR
 SYMBOLS TO SHOW THE LOCATIONS OF ALL SHUTOFF VALVES FOR
 THE GAS PIPING SYSTEMS- SECS. 5.1.4.1.1- 5.1.4.7 NFPA
 99. A) PROVIDE VALVE LABELING DETAILS- SEC. 5.1.11.2.1.
  
 13) FAILED. NO REPONSE OR INFORMATION PROVIDED. P103:
 PROVIDE A GAS STATION INLET AND OUTLET DETAIL- SECS.
 15.3.2.3 & 5.1.5 NFPA 99. A) PROVIDE STATION LABELING
 DETAILS- SEC. 5.1.11.3.1.
  
 14) FAILED. NO RESPONSE OR INFORMATION PROVIDED. P103,
 P501, & P601: PROVIDE MANUFACTURER'S SPECIFICATIONS FOR
 ALL COMPONENTS OF THE WAGD SYSTEM- SECS. 15.3.2.1.7,
 5.1.3.8- 5.1.3.8.3 NFPA 99. A) PROVIDE EXHAUST DETAILS-
 SEC. 5.1.3.7.7 NFPA 99.
  
 17) FAILED. REQUESTED DIAGRAM NOT PROVIDED. P103, P501,
 P601: PROVIDE COMPRESSOR INTAKE AND VACUUM EXHAUST
 PIPING DIAGRAMS SHOWING THE TYPES AND SIZES OF PIPING,
 PIPING RUNS AND TERMINATION LOCATIONS WITH CLEARANCE
 DISTANCE MEASUREMENTS TO OTHER AIR INTAKES AND EXHAUST
 OUTLETS OR OPENINGS INTO THE BUILDING- SEC.
 5.1.3.6.3.11 & 5.1.3.7.7.1 NFPA 99, SEC. 107.2.1 WPB.
  
  
 19) FAILED. NO RESPONSE OR INFORMATION PROVIDED P103:
 PLACE A NOTE ON THE PLAN TO INDICATE THE MED-GAS SYSTEM
 INSTALLED SHALL BE CERTIFIED IN ACCORDANCE WITH ASSE
 6010- SEC. 5.1.10.11.10.2 NFPA 99.
  
 20) FAILED. NO RESPONSE OR INFORMATION PROVIDED. PLEASE
 ACKNOWLEDGE RECEIPT AND REVIEW OF THE ORDINANCE. PLEASE
 NOTE THE COPIED SECTIONS BELOW DERIVED FROM THE CITY OF
 WEST PALM BEACH CODE OF ORDINANCES PERTAINING TO DENTAL
 AND MEDICAL FACILITY WASTE DISPOSAL. NOTE IN PARTICULAR
 SEC.90-126(I1) CONCERNING THE VACUUM SYSTEM.
  
 SECS. 90-126 (H-M)
 ALL OWNERS AND OPERATORS OF DENTAL FACILITIES THAT
 REMOVE OR PLACE AMALGAM FILLINGS SHALL COMPLY WITH THE
 FOLLOWING REPORTING AND WASTE MANAGEMENT PRACTICES:
 (1)
 FOR EXISTING SOURCES, A ONE-TIME COMPLIANCE REPORT IS
 DUE NO LATER THAN 90 DAYS AFTER TRANSFER OF OWNERSHIP.
 (2)
 FOR NEW SOURCES, A ONE-TIME COMPLIANCE REPORT IS DUE
 WITHIN 90 DAYS OF THE START OF DISCHARGE TO THE SEWER
 COLLECTION SYSTEM.
 (3)
 NO PERSON SHALL RINSE CHAIRSIDE TRAPS, VACUUM SCREENS,
 OR AMALGAM SEPARATORS EQUIPMENT IN A SINK OR OTHER
 CONNECTION TO THE SANITARY SEWER.
 (4)
 OWNERS AND OPERATORS OF DENTAL FACILITIES SHALL ENSURE
 THAT ALL STAFF MEMBERS WHO HANDLE AMALGAM WASTE ARE
 TRAINED IN PROPER HANDLING, MANAGEMENT AND DISPOSAL OF
 MERCURY-CONTAINING MATERIAL AND FIXER-CONTAINING
 SOLUTIONS AND SHALL MAINTAIN TRAINING RECORDS THAT
 SHALL BE AVAILABLE FOR INSPECTION BY THE CITY
 INDUSTRIAL PRETREATMENT DIVISION DURING NORMAL BUSINESS
 HOURS.
 (5)
 AMALGAM WASTE SHALL BE STORED AND MANAGED IN ACCORDANCE
 WITH THE INSTRUCTIONS OF THE RECYCLER OR HAULER OF SUCH
 MATERIALS.
 (6)
 BLEACH AND OTHER CHLORINE-CONTAINING DISINFECTANTS
 SHALL NOT BE USED TO DISINFECT THE VACUUM LINE SYSTEM.
 (7)
 THE USE OF BULK MERCURY IS PROHIBITED. ONLY
 PRE-CAPSULATED DENTAL AMALGAM IS PERMITTED.
 (I)
 ALL OWNERS AND OPERATORS OF DENTAL VACUUM SUCTION
 SYSTEMS, EXCEPT AS SET FORTH IN SUBSECTIONS (J) AND (K)
 OF THIS SECTION, SHALL COMPLY WITH THE FOLLOWING:
 (1)
 AN ISO 11143 OR ANSI/ADA STANDARD NO. 108 CERTIFIED
 AMALGAM SEPARATOR OR EQUIVALENT DEVICE SHALL BE
 INSTALLED FOR EACH DENTAL VACUUM SUCTION SYSTEM. THE
 INSTALLED DEVICE MUST BE ISO 11143 OR ANSI/ADA STANDARD
 NO. 108 CERTIFIED AS CAPABLE OF REMOVING A MINIMUM OF
 95 PERCENT OF AMALGAM. THE AMALGAM SEPARATOR SYSTEM
 SHALL BE CERTIFIED AT FLOW RATES COMPARABLE TO THE FLOW
 RATE OF THE ACTUAL VACUUM SUCTION SYSTEM OPERATION.
 NEITHER THE SEPARATOR DEVICE NOR THE RELATED PLUMBING
 SHALL INCLUDE AN AUTOMATIC FLOW BYPASS. FOR FACILITIES
 THAT REQUIRE AN AMALGAM SEPARATOR THAT EXCEEDS THE
 PRACTICAL CAPACITY OF ISO 11143 TEST METHODOLOGY, A
 NON-CERTIFIED SEPARATOR WILL BE ACCEPTED, PROVIDED THAT
 SMALLER UNITS FROM THE SAME MANUFACTURER AND OF THE
 SAME TECHNOLOGY ARE ISO-CERTIFIED.
 (2)
 PROOF OF CERTIFICATION AND INSTALLATION RECORDS SHALL
 BE SUBMITTED TO THE CITY INDUSTRIAL PRETREATMENT
 DIVISION WITHIN 30 DAYS OF INSTALLATION.
 (3)
 AMALGAM SEPARATORS SHALL BE MAINTAINED IN ACCORDANCE
 WITH MANUFACTURER RECOMMENDATIONS. INSTALLATION,
 CERTIFICATION, AND MAINTENANCE RECORDS SHALL BE
 AVAILABLE FOR IMMEDIATE INSPECTION UPON REQUEST
 THEREFOR BY THE CITY INDUSTRIAL PRETREATMENT DIVISION
 DESIGNEE DURING NORMAL BUSINESS HOURS. RECORDS SHALL BE
 MAINTAINED FOR A MINIMUM OF THREE YEARS.
 (J)
 FACILITIES WITH VACUUM SUCTION SYSTEMS THAT MEET ALL
 THE FOLLOWING CONDITIONS MAY APPLY TO THE CITY
 INDUSTRIAL PRETREATMENT DIVISION FOR AN EXEMPTION TO
 THE REQUIREMENTS OF SUBSECTION (I) OF THIS SECTION:
 (1)
 THE SYSTEM IS A DRY VACUUM PUMP SYSTEM WITH AN
 AIR-WATER SEPARATOR.
 (2)
 THE SEDIMENTATION TANK IS NON-BOTTOM DRAINING, WITH THE
 DRAIN ABOVE THE ANTICIPATED MAXIMUM LEVEL OF
 ACCUMULATED SLUDGE.
 (3)
 EVIDENCE OF REGULAR PUMP OUTS BY A LICENSED HAULER (A
 MINIMUM OF ONCE A YEAR, OR MORE OFTEN IF EITHER
 DIRECTED BY THE MANUFACTURER OR NECESSARY TO KEEP
 SOLIDS FROM EXITING THROUGH THE DRAIN) IS MAINTAINED
 AND OPEN TO INSPECTION BY CITY STAFF DURING NORMAL
 BUSINESS HOURS.
 (4)
 THE SYSTEM HAS NO DIRECT DISCHARGE PIPE TO THE SEWER ON
 THE BOTTOM OF THE SEDIMENTATION TANK.
 AN OWNER OR OPERATOR WHOSE FACILITY MEETS CONDITIONS
 (1) THROUGH (4) MAY APPLY FOR THIS EXEMPTION BY WRITTEN
 LETTER TO THE CITY INDUSTRIAL PRETREATMENT DIVISION. AN
 IPP DESIGNEE WILL REVIEW THE SYSTEM AND, IF THE
 EXEMPTION IS APPROVED, SHALL PROVIDE A WRITTEN LETTER
 OF EXEMPTION.
 AN EXEMPTION OBTAINED PURSUANT TO THIS SUBSECTION (J)
 SHALL EXPIRE UPON INSTALLATION OF A NEW VACUUM SYSTEM.
 UPON EXPIRATION OF THE EXEMPTION, THE FACILITY SHALL
 COMPLY WITH SUBSECTION (I) OF THIS SECTION BEFORE
 COMMENCING FURTHER OPERATION.
 (K)
 DENTAL DISCHARGERS THAT EXCLUSIVELY PRACTICE ONE OR
 MORE OF THE FOLLOWING SPECIALTIES ARE NOT SUBJECT TO
 THE REQUIREMENTS OF THIS SECTION: (1) ORTHODONTICS; (2)
 PERIODONTICS; (3) ORAL AND MAXILLOFACIAL SURGERY; (4)
 RADIOLOGY; (5) ORAL PATHOLOGY OR ORAL MEDICINE; (6)
 ENDODONTISTRY AND PROSTHODONTISTRY.
 (L)
 DENTAL PRACTICES THAT DO NOT PLACE DENTAL AMALGAM, AND
 DO NOT REMOVE AMALGAM EXCEPT IN LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, ARE EXEMPT FROM
 THE REQUIREMENTS OF THIS PART, PROVIDED THE DENTAL
 PRACTICE:
 (1)
 SUBMITS THE FOLLOWING STATEMENT TO THE CITY INDUSTRIAL
 PRETREATMENT DIVISION, SIGNED BY A RESPONSIBLE
 CORPORATE OFFICER, GENERAL PARTNER, PROPRIETOR, OR A
 DULY AUTHORIZED REPRESENTATIVE BY THE APPLICABLE
 COMPLIANCE DEADLINE IDENTIFIED IN SECTION 90-126(H)(1)
 AND 90-126(H)(2):
 "THIS FACILITY IS A DENTAL DISCHARGER SUBJECT TO THIS
 RULE AND DOES NOT PLACE OR REMOVE DENTAL AMALGAM EXCEPT
 IN LIMITED EMERGENCY OR UNPLANNED, UNANTICIPATED
 CIRCUMSTANCES. I AM A RESPONSIBLE CORPORATE OFFICER, A
 GENERAL PARTNER OR PROPRIETOR (IF THE FACILITY IS A
 PARTNERSHIP OR SOLE PROPRIETORSHIP), OR A DULY
 AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE
 REQUIREMENTS OF 403.12(L) OF THE ABOVE NAMED DENTAL
 FACILITY, AND CERTIFY UNDER PENALTY OF LAW THAT THIS
 DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY
 DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM
 DESIGNED TO ASSURE THAT QUALIFIED PERSONNEL PROPERLY
 GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON
 MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE
 SYSTEM, OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR
 GATHERING THE INFORMATION, THE INFORMATION SUBMITTED
 IS, TO THE BEST OF MY KNOWLEDGE AND BELIEF, TRUE,
 ACCURATE, AND COMPLETE. I AM AWARE THAT THERE ARE
 SIGNIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION,
 INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT FOR
 KNOWING VIOLATIONS."
 (2)
 REMOVES DENTAL AMALGAM FOR LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, LESS THAN TEN
 TIMES PER YEAR OR NO MORE THAN TEN PERCENT OF DENTAL
 PROCEDURES; AND
 (3)
 THE DENTAL PRACTICE NOTIFIES THE CITY OF ANY CHANGES
 AFFECTING THE APPLICABILITY OF THIS CERTIFICATION.
 (4)
 DISPOSAL OF HAULED WASTE FROM DENTAL FACILITIES TO THE
 SANITARY SEWER IS PROHIBITED IN ACCORDANCE WITH SECTION
 90-126(B)(8).
 (M)
 CONTROL OF DISCHARGE. IF ANY WASTES OR WASTEWATERS ARE
 DISCHARGED, OR ARE PROPOSED TO BE DISCHARGED, TO THE
 WWF WHICH CONTAIN THE SUBSTANCES OR POSSESS THE
 CHARACTERISTICS ENUMERATED IN THIS SECTION AS
 PROHIBITED BY THIS ARTICLE, DO NOT MEET APPLICABLE
 PRETREATMENT STANDARDS AND REQUIREMENTS, AND/OR WHICH
 MAY HAVE A DELETERIOUS EFFECT UPON THE WWF, ITS
 PROCESSES, EQUIPMENT, OR RECEIVING WATERS, OR WHICH
 OTHERWISE CREATE A HAZARD TO LIFE OR CONSTITUTE A
 PUBLIC NUISANCE, THE CITY MAY:
 (1)
 REJECT THE WASTES OR DENY OR CONDITION THE INTRODUCTION
 OF NEW SOURCES OF WASTEWATER TO THE WWF; OR
 (2)
 REQUIRE THE INDUSTRIAL USER TO DEMONSTRATE THAT
 IN-PLANT IMPROVEMENTS WILL MODIFY THE DISCHARGE TO SUCH
 A DEGREE AS TO BE ACCEPTABLE; AND/OR
 (3)
 REQUIRE PRETREATMENT OF THE INDUSTRIAL USER'S DISCHARGE
 TO ENSURE COMPLIANCE WITH THIS ARTICLE; AND/OR
 (4)
 REQUIRE PAYMENT OF AN INDUSTRIAL WASTE SURCHARGE TO
 COVER THE ADDED COST OF HANDLING AND TREATING EXCESS
 LOADS IMPOSED ON THE WWF BY SUCH DISCHARGE. SURCHARGE
 AMOUNTS SHALL BE ESTABLISHED BY A RESOLUTION OF THE
 CITY, TOGETHER WITH A SCHEDULE OF RATES AND FEES OF THE
 WWF. IMPOSITION OF INDUSTRIAL WASTE SURCHARGES FOR THE
 RECOVERY OF TREATMENT COSTS DOES NOT REPLACE OR
 SUPERSEDE THE REQUIREMENTS FOR PRETREATMENT FACILITIES,
 SHOULD THEY BE FOUND NECESSARY BY THE CITY.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop MEDGAS MEDICAL GAS
Rev No 1 Status F Date 2022-04-28 Cont ID  
Sent By ccole Date 2022-04-27 Time 17:31 Rev Time 0.00
Received By ccole Date 2022-04-19 Time 17:15 Sent To  
Notes
2022-04-27 17:33:111ST REVIEW FBC-2020 PLUMBING/ MED-GAS
 PERMIT- 22020213
 4/28/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 NFPA-99-2018
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW THE COMMENTS
 BELOW AND NOTE THAT INSTALLATION OF THE MED GAS SYSTEM
 MAY BE DONE UNDER A SEPARATE PERMIT.
  
 1) SHEET P103: REFER TO SEC. 15.1.1- 15.1.4 NFPA 99 AND
 INDICATE ON THE PLAN THE CATEGORY OF THE MED GAS
 SYSTEM- CATEGORY 1, 2, 3 OR 4. FOR PURPOSE OF REVIEW IT
 IS ASSUMED THE SYSTEM IS CATEGORY 1.
  
 2) P103 & P501: LABEL THE GAS CYLINDERS IN DETAIL
 10/P501 AS EITHER O2 OR N2O. INDICATE THE CU. FT.
 CAPACITIES OF THE CYLINDERS AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS- SECS. 15.3.3.1.1 & 5.1.3.1.1 NFPA 99.
 THE CYLINDERS SHALL BE DESIGNED, FABRICATED, TESTED AND
 STAMPED IN ACCORDANCE WITH REGULATIONS OF DOT,
 TRANSPORT CANADA (TC) TRANSPORTATION OF DANGEROUS GOODS
 REGULATIONS, OR THE ASME BOILER AND PRESSURE VESSEL
 CODE.
  
 3) P103 & P501: PROVIDE DOOR SIGNAGE DETAILS FOR THE
 GAS STORAGE CLOSET IN COMPLIANCE WITH SECS. 15.3.2.1 &
 5.1.3.1.9 NFPA 99.
  
 4) A101, P103, & P105: THE GAS ROOM MUST BE SEPARATED
 FROM OTHER AREAS OF THE BUILDING BY WALLS AND FLOORS
 HAVING BY A 1-HR. RATED FIRE RESISTANCE RATING WITH
 DOORS AND OTHER OPENING PROTECTIVES HAVE A 3/4 -HR.
 FIRE PROTECTION RATING- SECS.15.3.2.1 & 5.1.3.3.2 NFPA
 99. SEE RELATED CODE SECTIONS-SEC. 415.10.2 FBC B, SEC.
 9.3.6.6 NFPA 99, SEC. 6.4 NFPA, SEC. 502.9 FBC M.
  
 5) P103 & P501: FOR CYLINDERS EQUIPPED WITH RELIEF
 VALVES PLEASE PROVIDE VALVE VENTING DETAILS- SECS.
 15.3.2.1 & 5.1.3.5.6.1 NFPA 99. INCLUDE THE TYPES AND
 SIZES OF VENT PIPING, PIPING RUNS AND DISCHARGE
 LOCATIONS.
  
 6) P103 & P501: CONTINUOUS MECHANICAL VENTILATION AT A
 RATE OF 1 CFM PER 5 CU. FT. OF FLUID SHALL BE PROVIDED,
 AND NOT LESS THAN 50 CFM OR MORE THAN 500 CFM- SECS.
 15.3.2.1, 5.1.3.3.3.1, 19.3.6.5.3.1 & 9.3.6.5.3.2 NFPA
 99.
  
 7) P103 & P501: THE EXHAUST INLET SHALL FOR THE
 CYLINDER CLOSET SHALL BE UNOBSTRUCTED AND DRAW AIR
 WITHIN 1 FT. OF THE FLOOR ADJACENT TO THE CYLINDERS-
 SECS. 15.3.2.1, 5.1.3.3.3.1 & 9.3.6.5.3.3 NFPA 99.
  
 8) P103 & P501: INDICATE HOW MAKEUP AIR FOR THE EXHAUST
 WILL BE PROVIDED- SECS. 15.3.2.1, 5.1.3.3.3.1 &
 9.3.6.5.3.7 NFPA 99.
  
 9) P103 & P501 DETAIL 10/P510: LABEL THE TYPES AND
 SIZES OF FLEXIBLE SUPPLY CONNECTORS FROM THE TANK TO
 THE MANIFOLD- SEC. 5.1.10.11.6.1 NFPA 99 B) SHOW
 SHUTOFF VALVE, RELIEF VALVE AND CHECK VALVE LOCATIONS-
 SEC. 5.1.4.1.1 NFPA 99.
  
 10) P103 & P501: SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR ALL EQUIPMENT AND PIPING IN THE GAS ROOM INCLUDING
 THE MANIFOLD, ALARM SYSTEM, PIPING, REGULATORS, VALVES,
 AND FLEX HOSES- SECS. 15.3.2.1.4, 15.3.2.1.6, 15.3.2.11
 NFPA 99. SHOW THE LOCATIONS OF RELIEF VALVES AND
 PROVIDE RELIEF VALVE VENTING DETAILS INCLUDING TYPE OF
 VENT PIPING, VENT PIPING RUN AND DISCHARGE LOCATION-
 SEC. 15.3.2.11 NFPA 99.
  
 11) P103 & P501: PROVIDE 02, N20 PIPING SPECIFICATIONS
 AND SUBMIT MANUFACTURER'S SPECIFICATIONS- SECS.
 15.3.2.8, 5.1.10.1- 5.1.10.1.8 NFPA 99. A) INDICATE THE
 TYPE OF FITTINGS OR TECHNIQUES TO BE USED FOR PIPING
 TURNS, OFFSETS, AND OTHER CHANGES IN DIRECTION- SEC.
 5.1.10.3.1 ITEMS 1-5 NFPA 99. B) PROVIDE PIPE SUPPORT
 AND HANGING DETAILS- SEC. 5.1.10.11.4 NFPA 99. C)
 PROVIDE PIPE LABELING DETAILS- SE. 5.1.11.1.1 NFPA 99.
  
 12) P103: PROVIDE NOTES OR SYMBOLS TO SHOW THE
 LOCATIONS OF ALL SHUTOFF VALVES FOR THE GAS PIPING
 SYSTEMS- SECS. 5.1.4.1.1- 5.1.4.7 NFPA 99. A) PROVIDE
 VALVE LABELING DETAILS- SEC. 5.1.11.2.1.
  
 13) P103: PROVIDE A GAS STATION INLET AND OUTLET
 DETAIL- SECS. 15.3.2.3 & 5.1.5 NFPA 99. A) PROVIDE
 STATION LABELING DETAILS- SEC. 5.1.11.3.1.
  
 14) P103, P501, & P601: PROVIDE MANUFACTURER'S
 SPECIFICATIONS FOR ALL COMPONENTS OF THE WAGD SYSTEM-
 SECS. 15.3.2.1.7, 5.1.3.8- 5.1.3.8.3 NFPA 99. A)
 PROVIDE EXHAUST DETAILS- SEC. 5.1.3.7.7 NFPA 99.
  
 15) P103, P501 & P601: SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE AIR COMPRESSOR AND VACUUM PUMP-
 SECS. 15.3.3.3.4.1 & 15.3.3.5.2.1 NFPA 99.
  
 16) P103, P501, P601: PROVIDE COMPRESSED AIR AND VACUUM
 PIPING AND FITTING SPECIFICATIONS- SEC. 15.3.3.7.1-
 15.3.3.7.3.4 NFPA 99. A) SHOW ALL SHUTOFF VALVE
 LOCATIONS FOR THE SYSTEMS.
  
 17) P103, P501, P601: PROVIDE COMPRESSOR INTAKE AND
 VACUUM EXHAUST PIPING DIAGRAMS SHOWING THE TYPES AND
 SIZES OF PIPING, PIPING RUNS AND TERMINATION LOCATIONS
 WITH CLEARANCE DISTANCE MEASUREMENTS TO OTHER AIR
 INTAKES AND EXHAUST OUTLETS OR OPENINGS INTO THE
 BUILDING- SEC. 5.1.3.6.3.11 & 5.1.3.7.7.1 NFPA 99, SEC.
 107.2.1 WPB.
  
 18) P103: INDICATE HOW THE EQUIPMENT ROOM WILL BE
 VENTILATED- SEC. 15.3.3.2.3 NFPA 99.
  
 19) P103: PLACE A NOTE ON THE PLAN TO INDICATE THE
 MED-GAS SYSTEM INSTALLED SHALL BE CERTIFIED IN
 ACCORDANCE WITH ASSE 6010- SEC. 5.1.10.11.10.2 NFPA 99.
  
 20) PLEASE NOTE THE COPIED SECTIONS BELOW DERIVED FROM
 THE THE CITY OF WEST PALM BEACH CODE OF ORDINANCES
 PERTAINING TO DENTAL AND MEDICAL FACILITY WASTE
 DISPOSAL. NOTE IN PARTICULAR SEC.90-126(I1) CONCERNING
 THE VACUUM SYSTEM.
  
 SECS. 90-126 (H-M)
 ALL OWNERS AND OPERATORS OF DENTAL FACILITIES THAT
 REMOVE OR PLACE AMALGAM FILLINGS SHALL COMPLY WITH THE
 FOLLOWING REPORTING AND WASTE MANAGEMENT PRACTICES:
 (1)
 FOR EXISTING SOURCES, A ONE-TIME COMPLIANCE REPORT IS
 DUE NO LATER THAN 90 DAYS AFTER TRANSFER OF OWNERSHIP.
 (2)
 FOR NEW SOURCES, A ONE-TIME COMPLIANCE REPORT IS DUE
 WITHIN 90 DAYS OF THE START OF DISCHARGE TO THE SEWER
 COLLECTION SYSTEM.
 (3)
 NO PERSON SHALL RINSE CHAIRSIDE TRAPS, VACUUM SCREENS,
 OR AMALGAM SEPARATORS EQUIPMENT IN A SINK OR OTHER
 CONNECTION TO THE SANITARY SEWER.
 (4)
 OWNERS AND OPERATORS OF DENTAL FACILITIES SHALL ENSURE
 THAT ALL STAFF MEMBERS WHO HANDLE AMALGAM WASTE ARE
 TRAINED IN PROPER HANDLING, MANAGEMENT AND DISPOSAL OF
 MERCURY-CONTAINING MATERIAL AND FIXER-CONTAINING
 SOLUTIONS AND SHALL MAINTAIN TRAINING RECORDS THAT
 SHALL BE AVAILABLE FOR INSPECTION BY THE CITY
 INDUSTRIAL PRETREATMENT DIVISION DURING NORMAL BUSINESS
 HOURS.
 (5)
 AMALGAM WASTE SHALL BE STORED AND MANAGED IN ACCORDANCE
 WITH THE INSTRUCTIONS OF THE RECYCLER OR HAULER OF SUCH
 MATERIALS.
 (6)
 BLEACH AND OTHER CHLORINE-CONTAINING DISINFECTANTS
 SHALL NOT BE USED TO DISINFECT THE VACUUM LINE SYSTEM.
 (7)
 THE USE OF BULK MERCURY IS PROHIBITED. ONLY
 PRE-CAPSULATED DENTAL AMALGAM IS PERMITTED.
 (I)
 ALL OWNERS AND OPERATORS OF DENTAL VACUUM SUCTION
 SYSTEMS, EXCEPT AS SET FORTH IN SUBSECTIONS (J) AND (K)
 OF THIS SECTION, SHALL COMPLY WITH THE FOLLOWING:
 (1)
 AN ISO 11143 OR ANSI/ADA STANDARD NO. 108 CERTIFIED
 AMALGAM SEPARATOR OR EQUIVALENT DEVICE SHALL BE
 INSTALLED FOR EACH DENTAL VACUUM SUCTION SYSTEM. THE
 INSTALLED DEVICE MUST BE ISO 11143 OR ANSI/ADA STANDARD
 NO. 108 CERTIFIED AS CAPABLE OF REMOVING A MINIMUM OF
 95 PERCENT OF AMALGAM. THE AMALGAM SEPARATOR SYSTEM
 SHALL BE CERTIFIED AT FLOW RATES COMPARABLE TO THE FLOW
 RATE OF THE ACTUAL VACUUM SUCTION SYSTEM OPERATION.
 NEITHER THE SEPARATOR DEVICE NOR THE RELATED PLUMBING
 SHALL INCLUDE AN AUTOMATIC FLOW BYPASS. FOR FACILITIES
 THAT REQUIRE AN AMALGAM SEPARATOR THAT EXCEEDS THE
 PRACTICAL CAPACITY OF ISO 11143 TEST METHODOLOGY, A
 NON-CERTIFIED SEPARATOR WILL BE ACCEPTED, PROVIDED THAT
 SMALLER UNITS FROM THE SAME MANUFACTURER AND OF THE
 SAME TECHNOLOGY ARE ISO-CERTIFIED.
 (2)
 PROOF OF CERTIFICATION AND INSTALLATION RECORDS SHALL
 BE SUBMITTED TO THE CITY INDUSTRIAL PRETREATMENT
 DIVISION WITHIN 30 DAYS OF INSTALLATION.
 (3)
 AMALGAM SEPARATORS SHALL BE MAINTAINED IN ACCORDANCE
 WITH MANUFACTURER RECOMMENDATIONS. INSTALLATION,
 CERTIFICATION, AND MAINTENANCE RECORDS SHALL BE
 AVAILABLE FOR IMMEDIATE INSPECTION UPON REQUEST
 THEREFOR BY THE CITY INDUSTRIAL PRETREATMENT DIVISION
 DESIGNEE DURING NORMAL BUSINESS HOURS. RECORDS SHALL BE
 MAINTAINED FOR A MINIMUM OF THREE YEARS.
 (J)
 FACILITIES WITH VACUUM SUCTION SYSTEMS THAT MEET ALL
 THE FOLLOWING CONDITIONS MAY APPLY TO THE CITY
 INDUSTRIAL PRETREATMENT DIVISION FOR AN EXEMPTION TO
 THE REQUIREMENTS OF SUBSECTION (I) OF THIS SECTION:
 (1)
 THE SYSTEM IS A DRY VACUUM PUMP SYSTEM WITH AN
 AIR-WATER SEPARATOR.
 (2)
 THE SEDIMENTATION TANK IS NON-BOTTOM DRAINING, WITH THE
 DRAIN ABOVE THE ANTICIPATED MAXIMUM LEVEL OF
 ACCUMULATED SLUDGE.
 (3)
 EVIDENCE OF REGULAR PUMP OUTS BY A LICENSED HAULER (A
 MINIMUM OF ONCE A YEAR, OR MORE OFTEN IF EITHER
 DIRECTED BY THE MANUFACTURER OR NECESSARY TO KEEP
 SOLIDS FROM EXITING THROUGH THE DRAIN) IS MAINTAINED
 AND OPEN TO INSPECTION BY CITY STAFF DURING NORMAL
 BUSINESS HOURS.
 (4)
 THE SYSTEM HAS NO DIRECT DISCHARGE PIPE TO THE SEWER ON
 THE BOTTOM OF THE SEDIMENTATION TANK.
 AN OWNER OR OPERATOR WHOSE FACILITY MEETS CONDITIONS
 (1) THROUGH (4) MAY APPLY FOR THIS EXEMPTION BY WRITTEN
 LETTER TO THE CITY INDUSTRIAL PRETREATMENT DIVISION. AN
 IPP DESIGNEE WILL REVIEW THE SYSTEM AND, IF THE
 EXEMPTION IS APPROVED, SHALL PROVIDE A WRITTEN LETTER
 OF EXEMPTION.
 AN EXEMPTION OBTAINED PURSUANT TO THIS SUBSECTION (J)
 SHALL EXPIRE UPON INSTALLATION OF A NEW VACUUM SYSTEM.
 UPON EXPIRATION OF THE EXEMPTION, THE FACILITY SHALL
 COMPLY WITH SUBSECTION (I) OF THIS SECTION BEFORE
 COMMENCING FURTHER OPERATION.
 (K)
 DENTAL DISCHARGERS THAT EXCLUSIVELY PRACTICE ONE OR
 MORE OF THE FOLLOWING SPECIALTIES ARE NOT SUBJECT TO
 THE REQUIREMENTS OF THIS SECTION: (1) ORTHODONTICS; (2)
 PERIODONTICS; (3) ORAL AND MAXILLOFACIAL SURGERY; (4)
 RADIOLOGY; (5) ORAL PATHOLOGY OR ORAL MEDICINE; (6)
 ENDODONTISTRY AND PROSTHODONTISTRY.
 (L)
 DENTAL PRACTICES THAT DO NOT PLACE DENTAL AMALGAM, AND
 DO NOT REMOVE AMALGAM EXCEPT IN LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, ARE EXEMPT FROM
 THE REQUIREMENTS OF THIS PART, PROVIDED THE DENTAL
 PRACTICE:
 (1)
 SUBMITS THE FOLLOWING STATEMENT TO THE CITY INDUSTRIAL
 PRETREATMENT DIVISION, SIGNED BY A RESPONSIBLE
 CORPORATE OFFICER, GENERAL PARTNER, PROPRIETOR, OR A
 DULY AUTHORIZED REPRESENTATIVE BY THE APPLICABLE
 COMPLIANCE DEADLINE IDENTIFIED IN SECTION 90-126(H)(1)
 AND 90-126(H)(2):
 "THIS FACILITY IS A DENTAL DISCHARGER SUBJECT TO THIS
 RULE AND DOES NOT PLACE OR REMOVE DENTAL AMALGAM EXCEPT
 IN LIMITED EMERGENCY OR UNPLANNED, UNANTICIPATED
 CIRCUMSTANCES. I AM A RESPONSIBLE CORPORATE OFFICER, A
 GENERAL PARTNER OR PROPRIETOR (IF THE FACILITY IS A
 PARTNERSHIP OR SOLE PROPRIETORSHIP), OR A DULY
 AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE
 REQUIREMENTS OF 403.12(L) OF THE ABOVE NAMED DENTAL
 FACILITY, AND CERTIFY UNDER PENALTY OF LAW THAT THIS
 DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY
 DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM
 DESIGNED TO ASSURE THAT QUALIFIED PERSONNEL PROPERLY
 GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON
 MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE
 SYSTEM, OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR
 GATHERING THE INFORMATION, THE INFORMATION SUBMITTED
 IS, TO THE BEST OF MY KNOWLEDGE AND BELIEF, TRUE,
 ACCURATE, AND COMPLETE. I AM AWARE THAT THERE ARE
 SIGNIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION,
 INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT FOR
 KNOWING VIOLATIONS."
 (2)
 REMOVES DENTAL AMALGAM FOR LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, LESS THAN TEN
 TIMES PER YEAR OR NO MORE THAN TEN PERCENT OF DENTAL
 PROCEDURES; AND
 (3)
 THE DENTAL PRACTICE NOTIFIES THE CITY OF ANY CHANGES
 AFFECTING THE APPLICABILITY OF THIS CERTIFICATION.
 (4)
 DISPOSAL OF HAULED WASTE FROM DENTAL FACILITIES TO THE
 SANITARY SEWER IS PROHIBITED IN ACCORDANCE WITH SECTION
 90-126(B)(8).
 (M)
 CONTROL OF DISCHARGE. IF ANY WASTES OR WASTEWATERS ARE
 DISCHARGED, OR ARE PROPOSED TO BE DISCHARGED, TO THE
 WWF WHICH CONTAIN THE SUBSTANCES OR POSSESS THE
 CHARACTERISTICS ENUMERATED IN THIS SECTION AS
 PROHIBITED BY THIS ARTICLE, DO NOT MEET APPLICABLE
 PRETREATMENT STANDARDS AND REQUIREMENTS, AND/OR WHICH
 MAY HAVE A DELETERIOUS EFFECT UPON THE WWF, ITS
 PROCESSES, EQUIPMENT, OR RECEIVING WATERS, OR WHICH
 OTHERWISE CREATE A HAZARD TO LIFE OR CONSTITUTE A
 PUBLIC NUISANCE, THE CITY MAY:
 (1)
 REJECT THE WASTES OR DENY OR CONDITION THE INTRODUCTION
 OF NEW SOURCES OF WASTEWATER TO THE WWF; OR
 (2)
 REQUIRE THE INDUSTRIAL USER TO DEMONSTRATE THAT
 IN-PLANT IMPROVEMENTS WILL MODIFY THE DISCHARGE TO SUCH
 A DEGREE AS TO BE ACCEPTABLE; AND/OR
 (3)
 REQUIRE PRETREATMENT OF THE INDUSTRIAL USER'S DISCHARGE
 TO ENSURE COMPLIANCE WITH THIS ARTICLE; AND/OR
 (4)
 REQUIRE PAYMENT OF AN INDUSTRIAL WASTE SURCHARGE TO
 COVER THE ADDED COST OF HANDLING AND TREATING EXCESS
 LOADS IMPOSED ON THE WWF BY SUCH DISCHARGE. SURCHARGE
 AMOUNTS SHALL BE ESTABLISHED BY A RESOLUTION OF THE
 CITY, TOGETHER WITH A SCHEDULE OF RATES AND FEES OF THE
 WWF. IMPOSITION OF INDUSTRIAL WASTE SURCHARGES FOR THE
 RECOVERY OF TREATMENT COSTS DOES NOT REPLACE OR
 SUPERSEDE THE REQUIREMENTS FOR PRETREATMENT FACILITIES,
 SHOULD THEY BE FOUND NECESSARY BY THE CITY.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 07:45 Rev Time 0.00
Received By ccole Date 2022-10-03 Time 09:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2022-08-02 Cont ID  
Sent By ccole Date 2022-08-02 Time 10:35 Rev Time 0.00
Received By ccole Date 2022-08-01 Time 11:24 Sent To  
Notes
2022-08-02 10:38:433RD REVIEW FBC-2020 PLUMBING
 PERMIT- 22020213
 8/2/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST AND 2ND REVIEW ARE LISTED BELOW WITH ADDITIONAL
 NOTES. PLEASE REVIEW THE COMMENTS AND IF YOU QUESTIONS
 PLEASE CONTACT ME FOR ASSISTANCE.
  
 5) FAILED. P102: PROVIDE A MASTER THERMOSTATIC MIXING
 VALVE AT THE WATER HEATER OR INDIVIDUAL MIXING VALVES
 AT ALL HOT WATER SUPPLIED FIXTURES- SEC. 607.1.1 FBC P.
 HOT WATER AT A MINIMUM TEMPERATURE 0F 110 DEGREES F IS
 REQUIRED AT THE LAB SINK P-3E AND FROM ONE BOWL OF LAB
 SINK P-9 PER SEC. 607.1 FBC P. PLEASE CORRECT THE NOTES
 IN THE PLUMBING FIXTURE SCHEDULE ON P601 AND PROVIDE A
 MEANS OF LIMITING THE HOT WATER TEMPERATURE DELIVERY AT
 THE SINKS- SEC. 607.1.1. ACKNOWLEDGED THAT THE EYE WASH
 IN IN COMPLIANCE. THE MANUFACTURER'S SPECIFICATIONS AND
 INSTALLATION GUIDELINES WILL BE DEFERRED SUBMITTALS.
  
 6) FAILED. P102: NOTE #3 FOR THE WATER HEATER IS BEING
 USED TO IDENTIFY ANOTHER UNKNOWN PIECE OF EQUIPMENT IN
 THE RM 121. PLEASE CORRECT THE NOTE AND ADD THE
 EQUIPMENT TO THE SCHEDULE- SEC. 107.2.1 WPB. THE
 EQUIPMENT PLAN AND SCHEDULE INDICATE A WATER SOLENOID
 VALVE AT NOTE #3. PLEASE PROVIDE A DIFFERENT NUMBERED
 NOTE AND A DETAIL FOR THE ASSEMBLY ON SHEET P501.
  
 NEW COMMENT
  
 1) REFER TO SEC. 107.3.4.1 WPB AND PROVIDE A LIST OF
 DEFERRED SUBMITTALS ON TJHE PLAN INCLUDING BUT NOT
 LIMITED TO:
 EYEWASH STATION
 PLASTER TRAPS
 WATER HEATER
 WASHING MACHINE
 LINT INTERCEPTOR
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-06-07 Cont ID  
Sent By ccole Date 2022-06-07 Time 09:15 Rev Time 0.00
Received By ccole Date 2022-06-07 Time 08:37 Sent To  
Notes
2022-06-07 13:32:412ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22020213
 6/7/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES.
 PLEASE NOTE THAT THE COMMENT RESPONSES FROM THE
 ARCHITECT WERE INCOMPLETE AND DID NOT ADDRESS ALL OF
 THE COMMENTS.
  
 1) FAILED. SHEET A501 DETAIL 2C: THE CENTERLINES OF THE
 TOILET PAPER DISPENSERS SHALL BE 7-INCHES MINIMUM AND
 9-INCHES MAXIMUM MEASURED FROM THE FRONTS OF THE WATER
 CLOSETS- SEC. AND FIG. 604.7 FBC ACC. CENTERLINE OF THE
 DISPENSER NOT THE ROLL AS THE DETAIL SHOWS. NEW
 COMMENT: ON SHEET A501 PLEASE CHANGE THE 54-INCH CLEAR
 FLOOR SPACE DIMESNION FOR THE WATER CLOSETS TO
 56-INCHES AS REQUIRED BY SEC. 604.3.1 FBC ACC. THE PLAN
 ALSO APPEARS TO SHOW A FIXED PIECE OF FURNITURE
 OBSTRUCTING THE CLEARANCE- SEC. 604.3.2.
  
 4) FAILED. A101 & A503: IN ACCORDANCE WITH SEC. 212.3
 FBC ACC- WHERE SINKS ARE PROVIDED, AT LEAST 5 PERCENT,
 BUT NO FEWER THAN ONE, OF EACH TYPE PROVIDED IN EACH
 ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH 606. PLEASE
 SHOW THE CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR
 THE ACCESSIBLE SINKS INCLUDING THE BREAKROOM, WORK AND
 EXAM SINKS- SEC. 606.2 FBC ACC. PROVIDE ELEVATION
 DETAILS FOR THE SINKS. MINIMUM OF ONE EXAM ROOM SINK
 SHALL BE ACCESSIBILE. PLEASE NOTE THAT THE EXAM ROOM
 SINKS ARE MISLABELED AS P-3A IN THE SANITARY RISER
 DRAWING. PLEASE PROVIDE P-3C LABELS AT THE SINKS.
  
 5) FAILED. P102: PROVIDE A MASTER THERMOSTATIC MIXING
 VALVE AT THE WATER HEATER OR INDIVIDUAL MIXING VALVES
 AT ALL HOT WATER SUPPLIED FIXTURES- SEC. 607.1.1 FBC P.
 THE RESPONSE LETTER CALLS OUT ASSE 1070 MIXING VALVES
 FOR TEMPERED DELIIVERY FROM THE LAVATORIES, HOWEVER A
 MEANS OF LIMITING THE HOT WATER TEMPERATURE DELIVERY AT
 THE OTHER SINKS IN THE FACILITY IS REQUIRED AND CANNOT
 BE THE THERMOSTAT EQUIPPED WITH THE WATER HEATER.
  
 6) FAILED. P102: NOTE #3 FOR THE WATER HEATER IS BEING
 USED TO IDENTIFY ANOTHER UNKNOWN PIECE OF EQUIPMENT IN
 THE RM 121. PLEASE CORRECT THE NOTE AND ADD THE
 EQUIPMENT TO THE SCHEDULE- SEC. 107.2.1 WPB. THE
 EQUIPMENT PLAN AND SCHEDULE INDICATE A SOLENOID VALVE
 AT NOTE #3. PLEASE PROVIDE A DIFFERENT NUMBERED NOTE
 AND A DETAIL FOR THE ASSEMBLY ON SHEET P501.
  
 7) FAILED. P101, P201, P501, P601: DETAILS 5/P501 &
 6/P501 APPEAR TO BE IN CONFLICT CONCERNING VACUUM PUMP
 DRAINAGE. PLEASE NOTE AN INDIRECT WASTE RECEPTOR IS
 REQUIRED PER SEC. 802.1.5 FBC P. PLEASE REVISE THE
 SANITARY DRAINAGE LAYOUT PLAN AND ISOMETRIC DRAWING TO
 SHOW THE FLOOR DRAIN, THE VENTING, AND TRAP SEAL
 PROTECTION- SEC. 107.3.5.1.3 WPB & SEC.1002.4.1 FBC P.
 REMOVE ALL NON-COMPLIANT OR INCONSISTENT DETAILS AND
 PROVIDE AN VACUUM INTAKE/EXHAUST DIAGRAM PER DETAIL
 7/P501. SHOW THE TYPE AND SIZE OF PIPING, PIPING RUNS,
 AND TERMINATION LOCATIONS- SEC. 107.2.1 WPB & SEC.
 1202.1 FBC P. A) SUBMIT MANUFACTURER'S SPECS FOR THE
 VACUUM, COMPRESSOR AND ALL ASSOCIATED PIPING AND
 APPURTENANCES- SEC. 107.2.1 WPB & SEC.1202.1 FBC P, AND
 SECS. 5.1.3.6.3.4- 5.1.3.6.3.11 & 5.1.3.7.2 NFPA 99.
 2ND REQUEST FOR VACUUM AND COMPRESSOR INTAKE AND
 EXHAUST DIAGRAMS PLEASE SHOW ON THE PLANS THE PIPING
 RUNS, TYPES AND SIZES OF PIPES, AND TERMINATION
 LOCATIONS. PLEASE NOTE THAT THE VACUUM MUST BE EQUIPPED
 WITH A HEAT EXCHANGER IF SCHEDULE 40 PVC EXHAUST PIPING
 IS TO BE USED.
  
 8) FAILED. NO RESPONSE PROVIDED. P101: CLARIFY IF THE
 COMPRESSOR WILL PRODUCE CONDENSATE AND PROVIDE A
 CONDENSATE DISPOSAL PLAN IF APPLICABLE- SECS. 314.2 &
 314.2.1 FBC P. THE SUBMITTED SPECIFICATIONS INDICATE
 THE COMPRESSOR REQUIRES A MEANS OF DISPOSING CONDENSATE
 FROM THE REMOTE AIR INTAKE AND MOSITURE FROM THE
 MEMBRANE DRYER- PAGE 10. A WASTE RECEPTOR SHALL BE
 PROVIDED IN THE EQUIPMENT ROOM- SEC. 802.1 FBC P.
  
 9) FAILED. NO RESPONSE PROVIDED. P102: PROVIDE A WATER
 RISER DRAWING- SEC. 107.3.5.1.3 WPB.
  
 12) FAILED. NO RESPONSE PROVIDED.P101 & P601: PLEASE
 PLACE NOTES ON THE PLAN TO IDENTIFY THE LOCATIONS OF
 THE WASHING MACHINE AND REQUIRED LINT TRAP- SECS. 406.1
 & 1003.6 FBC P. A) PROVIDE AN ENLARGED DETAIL SHOWING
 THE WATER SUPPLY PIPING CONNECTIONS, WATER HAMMER
 ARRESTOR, AND THE DRAINAGE AND VENT PIPE CONNECTIONS
 FOR THE INTERCEPTOR. SUBMIT MANUFACTURER'S SPECS FOR
 THE WASHING MACHINE AND LINT TRAP.
  
 13) FAILED. NO REPONSE PROVIDED. P102 NOTE 6: INDICATE
 THE RPZ BACKFLOW PREVENTER INSTALLATION WILL BE UNDER
 SEPARATE PERMIT- SEC. 105.1 FBC P. PLEASE NOTE THE
 FOLLOWING CONCERNING THE BACKFLOW PREVENTER FOR THE
 POTABLE WATER SERVICE (SHEET C-111) AND FOR THE WATER
 SUPPLY TO THE VACUUM SHALL BE UNDER SEPARATE PERMITS.
 DUE TO A CHANGE IN PROCESS, THE BACKFLOW PERMITS ARE
 REQUIRED TO BE SUBMITTED PRIOR TO ISSUANCE OF THE
 PRIMARY PERMIT (AS APPLICABLE). YOU CAN SUBMIT AN
 APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT HAVE
 A CONTRACTOR SELECTED BY EMAILING A COMPLETED PERMIT
 APPLICATION TO [email protected] . YOU WILL
 RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU
 MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE
 APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT
 YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER
 YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL
 AND I WILL CHANGE THE REVIEW STATUS TO PASS.
  
 14) FAILED. NO RESPONSES PROVIDED. PLEASE NOTE THE
 COPIED SECTIONS BELOW DERIVED FROM THE CITY OF WEST
 PALM BEACH CODE OF ORDINANCES PERTAINING TO DENTAL AND
 MEDICAL FACILITY WASTE DISPOSAL. NOTE IN PARTICULAR
 SEC.90-126(I1) CONCERNING THE VACUUM SYSTEM. PLEASE
 NOTE THAT MANUFACTURER'S SPECIFICATIONS FOR THE AMALGAM
 SEPARATOR WERE NOT SUBMITTED FOR REVIEW.
 AN ISO 11143 OR ANSI/ADA STANDARD NO. 108 CERTIFIED
 AMALGAM SEPARATOR OR EQUIVALENT DEVICE SHALL BE
 INSTALLED FOR EACH DENTAL VACUUM SUCTION SYSTEM. THE
 INSTALLED DEVICE MUST BE ISO 11143 OR ANSI/ADA STANDARD
 NO. 108 CERTIFIED AS CAPABLE OF REMOVING A MINIMUM OF
 95 PERCENT OF AMALGAM. THE AMALGAM SEPARATOR SYSTEM
 SHALL BE CERTIFIED AT FLOW RATES COMPARABLE TO THE FLOW
 RATE OF THE ACTUAL VACUUM SUCTION SYSTEM OPERATION.
 NEITHER THE SEPARATOR DEVICE NOR THE RELATED PLUMBING
 SHALL INCLUDE AN AUTOMATIC FLOW BYPASS. FOR FACILITIES
 THAT REQUIRE AN AMALGAM SEPARATOR THAT EXCEEDS THE
 PRACTICAL CAPACITY OF ISO 11143 TEST METHODOLOGY, A
 NON-CERTIFIED SEPARATOR WILL BE ACCEPTED, PROVIDED THAT
 SMALLER UNITS FROM THE SAME MANUFACTURER AND OF THE
 SAME TECHNOLOGY ARE ISO-CERTIFIED.
  
 CONCERNING THE ITEMS BELOW PLEASE ACKNOWLEDGE RECEIPT
 AND REVIEW OF THE ORDINANCE.
  
 SECS. 90-126 (H-M)
 ALL OWNERS AND OPERATORS OF DENTAL FACILITIES THAT
 REMOVE OR PLACE AMALGAM FILLINGS SHALL COMPLY WITH THE
 FOLLOWING REPORTING AND WASTE MANAGEMENT PRACTICES:
 (1)
 FOR EXISTING SOURCES, A ONE-TIME COMPLIANCE REPORT IS
 DUE NO LATER THAN 90 DAYS AFTER TRANSFER OF OWNERSHIP.
 (2)
 FOR NEW SOURCES, A ONE-TIME COMPLIANCE REPORT IS DUE
 WITHIN 90 DAYS OF THE START OF DISCHARGE TO THE SEWER
 COLLECTION SYSTEM.
 (3)
 NO PERSON SHALL RINSE CHAIRSIDE TRAPS, VACUUM SCREENS,
 OR AMALGAM SEPARATORS EQUIPMENT IN A SINK OR OTHER
 CONNECTION TO THE SANITARY SEWER.
 (4)
 OWNERS AND OPERATORS OF DENTAL FACILITIES SHALL ENSURE
 THAT ALL STAFF MEMBERS WHO HANDLE AMALGAM WASTE ARE
 TRAINED IN PROPER HANDLING, MANAGEMENT AND DISPOSAL OF
 MERCURY-CONTAINING MATERIAL AND FIXER-CONTAINING
 SOLUTIONS AND SHALL MAINTAIN TRAINING RECORDS THAT
 SHALL BE AVAILABLE FOR INSPECTION BY THE CITY
 INDUSTRIAL PRETREATMENT DIVISION DURING NORMAL BUSINESS
 HOURS.
 (5)
 AMALGAM WASTE SHALL BE STORED AND MANAGED IN ACCORDANCE
 WITH THE INSTRUCTIONS OF THE RECYCLER OR HAULER OF SUCH
 MATERIALS.
 (6)
 BLEACH AND OTHER CHLORINE-CONTAINING DISINFECTANTS
 SHALL NOT BE USED TO DISINFECT THE VACUUM LINE SYSTEM.
 (7)
 THE USE OF BULK MERCURY IS PROHIBITED. ONLY
 PRE-CAPSULATED DENTAL AMALGAM IS PERMITTED.
 (I)
 ALL OWNERS AND OPERATORS OF DENTAL VACUUM SUCTION
 SYSTEMS, EXCEPT AS SET FORTH IN SUBSECTIONS (J) AND (K)
 OF THIS SECTION, SHALL COMPLY WITH THE FOLLOWING:
 (1)
 AN ISO 11143 OR ANSI/ADA STANDARD NO. 108 CERTIFIED
 AMALGAM SEPARATOR OR EQUIVALENT DEVICE SHALL BE
 INSTALLED FOR EACH DENTAL VACUUM SUCTION SYSTEM. THE
 INSTALLED DEVICE MUST BE ISO 11143 OR ANSI/ADA STANDARD
 NO. 108 CERTIFIED AS CAPABLE OF REMOVING A MINIMUM OF
 95 PERCENT OF AMALGAM. THE AMALGAM SEPARATOR SYSTEM
 SHALL BE CERTIFIED AT FLOW RATES COMPARABLE TO THE FLOW
 RATE OF THE ACTUAL VACUUM SUCTION SYSTEM OPERATION.
 NEITHER THE SEPARATOR DEVICE NOR THE RELATED PLUMBING
 SHALL INCLUDE AN AUTOMATIC FLOW BYPASS. FOR FACILITIES
 THAT REQUIRE AN AMALGAM SEPARATOR THAT EXCEEDS THE
 PRACTICAL CAPACITY OF ISO 11143 TEST METHODOLOGY, A
 NON-CERTIFIED SEPARATOR WILL BE ACCEPTED, PROVIDED THAT
 SMALLER UNITS FROM THE SAME MANUFACTURER AND OF THE
 SAME TECHNOLOGY ARE ISO-CERTIFIED.
 (2)
 PROOF OF CERTIFICATION AND INSTALLATION RECORDS SHALL
 BE SUBMITTED TO THE CITY INDUSTRIAL PRETREATMENT
 DIVISION WITHIN 30 DAYS OF INSTALLATION.
 (3)
 AMALGAM SEPARATORS SHALL BE MAINTAINED IN ACCORDANCE
 WITH MANUFACTURER RECOMMENDATIONS. INSTALLATION,
 CERTIFICATION, AND MAINTENANCE RECORDS SHALL BE
 AVAILABLE FOR IMMEDIATE INSPECTION UPON REQUEST
 THEREFOR BY THE CITY INDUSTRIAL PRETREATMENT DIVISION
 DESIGNEE DURING NORMAL BUSINESS HOURS. RECORDS SHALL BE
 MAINTAINED FOR A MINIMUM OF THREE YEARS.
 (J)
 FACILITIES WITH VACUUM SUCTION SYSTEMS THAT MEET ALL
 THE FOLLOWING CONDITIONS MAY APPLY TO THE CITY
 INDUSTRIAL PRETREATMENT DIVISION FOR AN EXEMPTION TO
 THE REQUIREMENTS OF SUBSECTION (I) OF THIS SECTION:
 (1)
 THE SYSTEM IS A DRY VACUUM PUMP SYSTEM WITH AN
 AIR-WATER SEPARATOR.
 (2)
 THE SEDIMENTATION TANK IS NON-BOTTOM DRAINING, WITH THE
 DRAIN ABOVE THE ANTICIPATED MAXIMUM LEVEL OF
 ACCUMULATED SLUDGE.
 (3)
 EVIDENCE OF REGULAR PUMP OUTS BY A LICENSED HAULER (A
 MINIMUM OF ONCE A YEAR, OR MORE OFTEN IF EITHER
 DIRECTED BY THE MANUFACTURER OR NECESSARY TO KEEP
 SOLIDS FROM EXITING THROUGH THE DRAIN) IS MAINTAINED
 AND OPEN TO INSPECTION BY CITY STAFF DURING NORMAL
 BUSINESS HOURS.
 (4)
 THE SYSTEM HAS NO DIRECT DISCHARGE PIPE TO THE SEWER ON
 THE BOTTOM OF THE SEDIMENTATION TANK.
 AN OWNER OR OPERATOR WHOSE FACILITY MEETS CONDITIONS
 (1) THROUGH (4) MAY APPLY FOR THIS EXEMPTION BY WRITTEN
 LETTER TO THE CITY INDUSTRIAL PRETREATMENT DIVISION. AN
 IPP DESIGNEE WILL REVIEW THE SYSTEM AND, IF THE
 EXEMPTION IS APPROVED, SHALL PROVIDE A WRITTEN LETTER
 OF EXEMPTION.
 AN EXEMPTION OBTAINED PURSUANT TO THIS SUBSECTION (J)
 SHALL EXPIRE UPON INSTALLATION OF A NEW VACUUM SYSTEM.
 UPON EXPIRATION OF THE EXEMPTION, THE FACILITY SHALL
 COMPLY WITH SUBSECTION (I) OF THIS SECTION BEFORE
 COMMENCING FURTHER OPERATION.
 (K)
 DENTAL DISCHARGERS THAT EXCLUSIVELY PRACTICE ONE OR
 MORE OF THE FOLLOWING SPECIALTIES ARE NOT SUBJECT TO
 THE REQUIREMENTS OF THIS SECTION: (1) ORTHODONTICS; (2)
 PERIODONTICS; (3) ORAL AND MAXILLOFACIAL SURGERY; (4)
 RADIOLOGY; (5) ORAL PATHOLOGY OR ORAL MEDICINE; (6)
 ENDODONTISTRY AND PROSTHODONTISTRY.
 (L)
 DENTAL PRACTICES THAT DO NOT PLACE DENTAL AMALGAM, AND
 DO NOT REMOVE AMALGAM EXCEPT IN LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, ARE EXEMPT FROM
 THE REQUIREMENTS OF THIS PART, PROVIDED THE DENTAL
 PRACTICE:
 (1)
 SUBMITS THE FOLLOWING STATEMENT TO THE CITY INDUSTRIAL
 PRETREATMENT DIVISION, SIGNED BY A RESPONSIBLE
 CORPORATE OFFICER, GENERAL PARTNER, PROPRIETOR, OR A
 DULY AUTHORIZED REPRESENTATIVE BY THE APPLICABLE
 COMPLIANCE DEADLINE IDENTIFIED IN SECTION 90-126(H)(1)
 AND 90-126(H)(2):
 "THIS FACILITY IS A DENTAL DISCHARGER SUBJECT TO THIS
 RULE AND DOES NOT PLACE OR REMOVE DENTAL AMALGAM EXCEPT
 IN LIMITED EMERGENCY OR UNPLANNED, UNANTICIPATED
 CIRCUMSTANCES. I AM A RESPONSIBLE CORPORATE OFFICER, A
 GENERAL PARTNER OR PROPRIETOR (IF THE FACILITY IS A
 PARTNERSHIP OR SOLE PROPRIETORSHIP), OR A DULY
 AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE
 REQUIREMENTS OF 403.12(L) OF THE ABOVE NAMED DENTAL
 FACILITY, AND CERTIFY UNDER PENALTY OF LAW THAT THIS
 DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY
 DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM
 DESIGNED TO ASSURE THAT QUALIFIED PERSONNEL PROPERLY
 GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON
 MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE
 SYSTEM, OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR
 GATHERING THE INFORMATION, THE INFORMATION SUBMITTED
 IS, TO THE BEST OF MY KNOWLEDGE AND BELIEF, TRUE,
 ACCURATE, AND COMPLETE. I AM AWARE THAT THERE ARE
 SIGNIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION,
 INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT FOR
 KNOWING VIOLATIONS."
 (2)
 REMOVES DENTAL AMALGAM FOR LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, LESS THAN TEN
 TIMES PER YEAR OR NO MORE THAN TEN PERCENT OF DENTAL
 PROCEDURES; AND
 (3)
 THE DENTAL PRACTICE NOTIFIES THE CITY OF ANY CHANGES
 AFFECTING THE APPLICABILITY OF THIS CERTIFICATION.
 (4)
 DISPOSAL OF HAULED WASTE FROM DENTAL FACILITIES TO THE
 SANITARY SEWER IS PROHIBITED IN ACCORDANCE WITH SECTION
 90-126(B)(8).
 (M)
 CONTROL OF DISCHARGE. IF ANY WASTES OR WASTEWATERS ARE
 DISCHARGED, OR ARE PROPOSED TO BE DISCHARGED, TO THE
 WWF WHICH CONTAIN THE SUBSTANCES OR POSSESS THE
 CHARACTERISTICS ENUMERATED IN THIS SECTION AS
 PROHIBITED BY THIS ARTICLE, DO NOT MEET APPLICABLE
 PRETREATMENT STANDARDS AND REQUIREMENTS, AND/OR WHICH
 MAY HAVE A DELETERIOUS EFFECT UPON THE WWF, ITS
 PROCESSES, EQUIPMENT, OR RECEIVING WATERS, OR WHICH
 OTHERWISE CREATE A HAZARD TO LIFE OR CONSTITUTE A
 PUBLIC NUISANCE, THE CITY MAY:
 (1)
 REJECT THE WASTES OR DENY OR CONDITION THE INTRODUCTION
 OF NEW SOURCES OF WASTEWATER TO THE WWF; OR
 (2)
 REQUIRE THE INDUSTRIAL USER TO DEMONSTRATE THAT
 IN-PLANT IMPROVEMENTS WILL MODIFY THE DISCHARGE TO SUCH
 A DEGREE AS TO BE ACCEPTABLE; AND/OR
 (3)
 REQUIRE PRETREATMENT OF THE INDUSTRIAL USER'S DISCHARGE
 TO ENSURE COMPLIANCE WITH THIS ARTICLE; AND/OR
 (4)
 REQUIRE PAYMENT OF AN INDUSTRIAL WASTE SURCHARGE TO
 COVER THE ADDED COST OF HANDLING AND TREATING EXCESS
 LOADS IMPOSED ON THE WWF BY SUCH DISCHARGE. SURCHARGE
 AMOUNTS SHALL BE ESTABLISHED BY A RESOLUTION OF THE
 CITY, TOGETHER WITH A SCHEDULE OF RATES AND FEES OF THE
 WWF. IMPOSITION OF INDUSTRIAL WASTE SURCHARGES FOR THE
 RECOVERY OF TREATMENT COSTS DOES NOT REPLACE OR
 SUPERSEDE THE REQUIREMENTS FOR PRETREATMENT FACILITIES,
 SHOULD THEY BE FOUND NECESSARY BY THE CITY.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-04-19 Cont ID  
Sent By ccole Date 2022-04-19 Time 17:12 Rev Time 0.00
Received By ccole Date 2022-04-19 Time 15:03 Sent To  
Notes
2022-04-19 17:12:581ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22020213
 4/19/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A501 DETAIL 2C: THE CENTERLINES OF THE TOILET
 PAPER DISPENSERS SHALL BE 7-INCHES MINIMUM AND 9-INCHES
 MAXIMUM MEASURED FROM THE FRONTS OF THE WATER CLOSETS-
 SEC. AND FIG. 604.7 FBC ACC.
  
 2) A501 DETAILS 2B & 2C: THE GRAB BAR HEIGHT
 MEASUREMENTS ARE SHOWN TO THE CENTER OF THE BARS AND
 NOT TO THE TOPS OF THE GRIPPING SURFACES- SEC. 609.4
 FBC ACC.
  
 3) A101 & A501 DRINKING FOUNTAINS: A) SHOW THE CLEAR
 FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE DRINKING
 FOUNTAINS- SEC. 602.2 FBC ACC. B) PROVIDE ELEVATION
 DETAILS SHOWING KNEE AND TOE CLEARANCES, SPOUT HEIGHTS,
 AND SPOUT LOCATIONS- SEC. 306, 307, & 602 FBC ACC. C)
 PLACE A NOTE TO INDICATE THE DRINKING FOUNTAINS ARE
 BARRIER-FREE TYPES OR PROVIDE BARRIERS PER SEC. 307.2
 FBC ACC.
  
 4) A101 & A503: IN ACCORDANCE WITH SEC. 212.3 FBC ACC-
 WHERE SINKS ARE PROVIDED, AT LEAST 5 PERCENT, BUT NO
 FEWER THAN ONE, OF EACH TYPE PROVIDED IN EACH
 ACCESSIBLE ROOM OR SPACE SHALL COMPLY WITH 606.
 PLEASE SHOW THE CLEAR FLOOR SPACE DIAGRAMS AND
 DIMENSIONS FOR THE ACCESSIBLE SINKS INCLUDING THE
 BREAKROOM, WORK AND EXAM SINKS- SEC. 606.2 FBC ACC.
 PROVIDE ELEVATION DETAILS FOR THE SINKS.
  
 5) P102: PROVIDE A MASTER THERMOSTATIC MIXING VALVE AT
 THE WATER HEATER OR INDIVIDUAL MIXING VALVES AT ALL HOT
 WATER SUPPLIED FIXTURES- SEC. 607.1.1 FBC P.
  
 6) P102: NOTE #3 FOR THE WATER HEASTER IS BEING USED TO
 IDENTIFY ANOTHER UNKNOWN PIECE OF EQUIPMENT IN THE RM
 121. PLEASE CORRECT THE NOTE AND ADD THE EQUIPMENT TO
 THE SCHEDULE- SEC. 107.2.1 WPB.
  
 7) P101, P201, P501, P601: DETAILS 5/P501 & 6/P501
 APPEAR TO BE IN CONFLICT CONCERNING VACUUM PUMP
 DRAINAGE. PLEASE NOTE AN INDIRECT WASTE RECEPTOR IS
 REQUIRED PER SEC. 802.1.5 FBC P. PLEASE REVISE THE
 SANITARY DRAINAGE LAYOUT PLAN AND ISOMETRIC DRAWING TO
 SHOW THE FLOOR DRAIN, THE VENTING, AND TRAP SEAL
 PROTECTION- SEC. 107.3.5.1.3 WPB & SEC.1002.4.1 FBC P.
 REMOVE ALL NON-COMPLIANT OR INCONSISTENT DETAILS AND
 PROVIDE AN VACUUM INTAKE/EXHAUST DIAGRAM PER DETAIL
 7/P501. SHOW THE TYPE AND SIZE OF PIPING, PIPING RUNS,
 AND TERMINATION LOCATIONS- SEC. 107.2.1 WPB & SEC.
 1202.1 FBC P. A) SUBMIT MANUFACTURER'S SPECS FOR THE
 VACUUM, COMPRESSOR AND ALL ASSOCIATED PIPING AND
 APPURTENANCES- SEC. 107.2.1 WPB & SEC.1202.1 FBC P, AND
 SECS. 5.1.3.6.3.4- 5.1.3.6.3.11 & 5.1.3.7.2 NFPA 99.
  
 8) P101: CLARIFY OIF THE COMPRESSOR WILL PRODUCE
 CONDENSATE AND PROVIDE A CONDENSATE DISPOSAL PLAN IF
 APPLICABLE- SECS. 314.2 & 314.2.1 FBC P.
  
 9) P102: PROVIDE A WATER RISER DRAWING- SEC.
 107.3.5.1.3 WPB.
  
 10) P601: PLEASE INDICATE THE EFFICIENCY RATING OF THE
 WATER HEATER IN THE EQUIPMENT SCHEDULE AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS- TABLE C404.1 FBC EC.
  
 11) P501 & P601: SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE PLASTER TRAPS- SEC. 107.2.1 WPB.
  
 12) P101 & P601: PLEASE PLACE NOTES ON THE PLAN TO
 IDENTIFY THE LOCATIONS OF THE WASHING MACHINE AND
 REQUIRED LINT TRAP- SECS. 406.1 & 1003.6 FBC P. A)
 PROVIDE AN ENLARGED DETAIL SHOWING THE WATER SUPPLY
 PIPING CONNECTIONS, WATER HAMMER ARRESTOR, AND THE
 DRAINAGE AND VENT PIPE CONNECTIONS FOR THE INTERCEPTOR.
 SUBMIT MANIUFACTURER'S SPECS FOR THE WASHINE MACHINE
 AND LINT TRRAP.
  
 13) P102 NOTE 6: INDICATE THE RPZ BACKFLOW PREVENTER
 INSTALLATION WILL BE UNDER SEPARATE PERMIT- SEC. 105.1
 FBC P.
  
 14) PLEASE NOTE THE COPIED SECTIONS BELOW DERIVED FROM
 THE THE CITY OF WEST PALM BEACH CODE OF ORDINANCES
 PERTAINING TO DENTAL AND MEDICAL FACILITY WASTE
 DISPOSAL. NOTE IN PARTICULAR SEC.90-126(I1) CONCERNING
 THE VACUUM SYSTEM.
  
 SECS. 90-126 (H-M)
 ALL OWNERS AND OPERATORS OF DENTAL FACILITIES THAT
 REMOVE OR PLACE AMALGAM FILLINGS SHALL COMPLY WITH THE
 FOLLOWING REPORTING AND WASTE MANAGEMENT PRACTICES:
 (1)
 FOR EXISTING SOURCES, A ONE-TIME COMPLIANCE REPORT IS
 DUE NO LATER THAN 90 DAYS AFTER TRANSFER OF OWNERSHIP.
 (2)
 FOR NEW SOURCES, A ONE-TIME COMPLIANCE REPORT IS DUE
 WITHIN 90 DAYS OF THE START OF DISCHARGE TO THE SEWER
 COLLECTION SYSTEM.
 (3)
 NO PERSON SHALL RINSE CHAIRSIDE TRAPS, VACUUM SCREENS,
 OR AMALGAM SEPARATORS EQUIPMENT IN A SINK OR OTHER
 CONNECTION TO THE SANITARY SEWER.
 (4)
 OWNERS AND OPERATORS OF DENTAL FACILITIES SHALL ENSURE
 THAT ALL STAFF MEMBERS WHO HANDLE AMALGAM WASTE ARE
 TRAINED IN PROPER HANDLING, MANAGEMENT AND DISPOSAL OF
 MERCURY-CONTAINING MATERIAL AND FIXER-CONTAINING
 SOLUTIONS AND SHALL MAINTAIN TRAINING RECORDS THAT
 SHALL BE AVAILABLE FOR INSPECTION BY THE CITY
 INDUSTRIAL PRETREATMENT DIVISION DURING NORMAL BUSINESS
 HOURS.
 (5)
 AMALGAM WASTE SHALL BE STORED AND MANAGED IN ACCORDANCE
 WITH THE INSTRUCTIONS OF THE RECYCLER OR HAULER OF SUCH
 MATERIALS.
 (6)
 BLEACH AND OTHER CHLORINE-CONTAINING DISINFECTANTS
 SHALL NOT BE USED TO DISINFECT THE VACUUM LINE SYSTEM.
 (7)
 THE USE OF BULK MERCURY IS PROHIBITED. ONLY
 PRE-CAPSULATED DENTAL AMALGAM IS PERMITTED.
 (I)
 ALL OWNERS AND OPERATORS OF DENTAL VACUUM SUCTION
 SYSTEMS, EXCEPT AS SET FORTH IN SUBSECTIONS (J) AND (K)
 OF THIS SECTION, SHALL COMPLY WITH THE FOLLOWING:
 (1)
 AN ISO 11143 OR ANSI/ADA STANDARD NO. 108 CERTIFIED
 AMALGAM SEPARATOR OR EQUIVALENT DEVICE SHALL BE
 INSTALLED FOR EACH DENTAL VACUUM SUCTION SYSTEM. THE
 INSTALLED DEVICE MUST BE ISO 11143 OR ANSI/ADA STANDARD
 NO. 108 CERTIFIED AS CAPABLE OF REMOVING A MINIMUM OF
 95 PERCENT OF AMALGAM. THE AMALGAM SEPARATOR SYSTEM
 SHALL BE CERTIFIED AT FLOW RATES COMPARABLE TO THE FLOW
 RATE OF THE ACTUAL VACUUM SUCTION SYSTEM OPERATION.
 NEITHER THE SEPARATOR DEVICE NOR THE RELATED PLUMBING
 SHALL INCLUDE AN AUTOMATIC FLOW BYPASS. FOR FACILITIES
 THAT REQUIRE AN AMALGAM SEPARATOR THAT EXCEEDS THE
 PRACTICAL CAPACITY OF ISO 11143 TEST METHODOLOGY, A
 NON-CERTIFIED SEPARATOR WILL BE ACCEPTED, PROVIDED THAT
 SMALLER UNITS FROM THE SAME MANUFACTURER AND OF THE
 SAME TECHNOLOGY ARE ISO-CERTIFIED.
 (2)
 PROOF OF CERTIFICATION AND INSTALLATION RECORDS SHALL
 BE SUBMITTED TO THE CITY INDUSTRIAL PRETREATMENT
 DIVISION WITHIN 30 DAYS OF INSTALLATION.
 (3)
 AMALGAM SEPARATORS SHALL BE MAINTAINED IN ACCORDANCE
 WITH MANUFACTURER RECOMMENDATIONS. INSTALLATION,
 CERTIFICATION, AND MAINTENANCE RECORDS SHALL BE
 AVAILABLE FOR IMMEDIATE INSPECTION UPON REQUEST
 THEREFOR BY THE CITY INDUSTRIAL PRETREATMENT DIVISION
 DESIGNEE DURING NORMAL BUSINESS HOURS. RECORDS SHALL BE
 MAINTAINED FOR A MINIMUM OF THREE YEARS.
 (J)
 FACILITIES WITH VACUUM SUCTION SYSTEMS THAT MEET ALL
 THE FOLLOWING CONDITIONS MAY APPLY TO THE CITY
 INDUSTRIAL PRETREATMENT DIVISION FOR AN EXEMPTION TO
 THE REQUIREMENTS OF SUBSECTION (I) OF THIS SECTION:
 (1)
 THE SYSTEM IS A DRY VACUUM PUMP SYSTEM WITH AN
 AIR-WATER SEPARATOR.
 (2)
 THE SEDIMENTATION TANK IS NON-BOTTOM DRAINING, WITH THE
 DRAIN ABOVE THE ANTICIPATED MAXIMUM LEVEL OF
 ACCUMULATED SLUDGE.
 (3)
 EVIDENCE OF REGULAR PUMP OUTS BY A LICENSED HAULER (A
 MINIMUM OF ONCE A YEAR, OR MORE OFTEN IF EITHER
 DIRECTED BY THE MANUFACTURER OR NECESSARY TO KEEP
 SOLIDS FROM EXITING THROUGH THE DRAIN) IS MAINTAINED
 AND OPEN TO INSPECTION BY CITY STAFF DURING NORMAL
 BUSINESS HOURS.
 (4)
 THE SYSTEM HAS NO DIRECT DISCHARGE PIPE TO THE SEWER ON
 THE BOTTOM OF THE SEDIMENTATION TANK.
 AN OWNER OR OPERATOR WHOSE FACILITY MEETS CONDITIONS
 (1) THROUGH (4) MAY APPLY FOR THIS EXEMPTION BY WRITTEN
 LETTER TO THE CITY INDUSTRIAL PRETREATMENT DIVISION. AN
 IPP DESIGNEE WILL REVIEW THE SYSTEM AND, IF THE
 EXEMPTION IS APPROVED, SHALL PROVIDE A WRITTEN LETTER
 OF EXEMPTION.
 AN EXEMPTION OBTAINED PURSUANT TO THIS SUBSECTION (J)
 SHALL EXPIRE UPON INSTALLATION OF A NEW VACUUM SYSTEM.
 UPON EXPIRATION OF THE EXEMPTION, THE FACILITY SHALL
 COMPLY WITH SUBSECTION (I) OF THIS SECTION BEFORE
 COMMENCING FURTHER OPERATION.
 (K)
 DENTAL DISCHARGERS THAT EXCLUSIVELY PRACTICE ONE OR
 MORE OF THE FOLLOWING SPECIALTIES ARE NOT SUBJECT TO
 THE REQUIREMENTS OF THIS SECTION: (1) ORTHODONTICS; (2)
 PERIODONTICS; (3) ORAL AND MAXILLOFACIAL SURGERY; (4)
 RADIOLOGY; (5) ORAL PATHOLOGY OR ORAL MEDICINE; (6)
 ENDODONTISTRY AND PROSTHODONTISTRY.
 (L)
 DENTAL PRACTICES THAT DO NOT PLACE DENTAL AMALGAM, AND
 DO NOT REMOVE AMALGAM EXCEPT IN LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, ARE EXEMPT FROM
 THE REQUIREMENTS OF THIS PART, PROVIDED THE DENTAL
 PRACTICE:
 (1)
 SUBMITS THE FOLLOWING STATEMENT TO THE CITY INDUSTRIAL
 PRETREATMENT DIVISION, SIGNED BY A RESPONSIBLE
 CORPORATE OFFICER, GENERAL PARTNER, PROPRIETOR, OR A
 DULY AUTHORIZED REPRESENTATIVE BY THE APPLICABLE
 COMPLIANCE DEADLINE IDENTIFIED IN SECTION 90-126(H)(1)
 AND 90-126(H)(2):
 "THIS FACILITY IS A DENTAL DISCHARGER SUBJECT TO THIS
 RULE AND DOES NOT PLACE OR REMOVE DENTAL AMALGAM EXCEPT
 IN LIMITED EMERGENCY OR UNPLANNED, UNANTICIPATED
 CIRCUMSTANCES. I AM A RESPONSIBLE CORPORATE OFFICER, A
 GENERAL PARTNER OR PROPRIETOR (IF THE FACILITY IS A
 PARTNERSHIP OR SOLE PROPRIETORSHIP), OR A DULY
 AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE
 REQUIREMENTS OF 403.12(L) OF THE ABOVE NAMED DENTAL
 FACILITY, AND CERTIFY UNDER PENALTY OF LAW THAT THIS
 DOCUMENT AND ALL ATTACHMENTS WERE PREPARED UNDER MY
 DIRECTION OR SUPERVISION IN ACCORDANCE WITH A SYSTEM
 DESIGNED TO ASSURE THAT QUALIFIED PERSONNEL PROPERLY
 GATHER AND EVALUATE THE INFORMATION SUBMITTED. BASED ON
 MY INQUIRY OF THE PERSON OR PERSONS WHO MANAGE THE
 SYSTEM, OR THOSE PERSONS DIRECTLY RESPONSIBLE FOR
 GATHERING THE INFORMATION, THE INFORMATION SUBMITTED
 IS, TO THE BEST OF MY KNOWLEDGE AND BELIEF, TRUE,
 ACCURATE, AND COMPLETE. I AM AWARE THAT THERE ARE
 SIGNIFICANT PENALTIES FOR SUBMITTING FALSE INFORMATION,
 INCLUDING THE POSSIBILITY OF FINE AND IMPRISONMENT FOR
 KNOWING VIOLATIONS."
 (2)
 REMOVES DENTAL AMALGAM FOR LIMITED EMERGENCY OR
 UNPLANNED, UNANTICIPATED CIRCUMSTANCES, LESS THAN TEN
 TIMES PER YEAR OR NO MORE THAN TEN PERCENT OF DENTAL
 PROCEDURES; AND
 (3)
 THE DENTAL PRACTICE NOTIFIES THE CITY OF ANY CHANGES
 AFFECTING THE APPLICABILITY OF THIS CERTIFICATION.
 (4)
 DISPOSAL OF HAULED WASTE FROM DENTAL FACILITIES TO THE
 SANITARY SEWER IS PROHIBITED IN ACCORDANCE WITH SECTION
 90-126(B)(8).
 (M)
 CONTROL OF DISCHARGE. IF ANY WASTES OR WASTEWATERS ARE
 DISCHARGED, OR ARE PROPOSED TO BE DISCHARGED, TO THE
 WWF WHICH CONTAIN THE SUBSTANCES OR POSSESS THE
 CHARACTERISTICS ENUMERATED IN THIS SECTION AS
 PROHIBITED BY THIS ARTICLE, DO NOT MEET APPLICABLE
 PRETREATMENT STANDARDS AND REQUIREMENTS, AND/OR WHICH
 MAY HAVE A DELETERIOUS EFFECT UPON THE WWF, ITS
 PROCESSES, EQUIPMENT, OR RECEIVING WATERS, OR WHICH
 OTHERWISE CREATE A HAZARD TO LIFE OR CONSTITUTE A
 PUBLIC NUISANCE, THE CITY MAY:
 (1)
 REJECT THE WASTES OR DENY OR CONDITION THE INTRODUCTION
 OF NEW SOURCES OF WASTEWATER TO THE WWF; OR
 (2)
 REQUIRE THE INDUSTRIAL USER TO DEMONSTRATE THAT
 IN-PLANT IMPROVEMENTS WILL MODIFY THE DISCHARGE TO SUCH
 A DEGREE AS TO BE ACCEPTABLE; AND/OR
 (3)
 REQUIRE PRETREATMENT OF THE INDUSTRIAL USER'S DISCHARGE
 TO ENSURE COMPLIANCE WITH THIS ARTICLE; AND/OR
 (4)
 REQUIRE PAYMENT OF AN INDUSTRIAL WASTE SURCHARGE TO
 COVER THE ADDED COST OF HANDLING AND TREATING EXCESS
 LOADS IMPOSED ON THE WWF BY SUCH DISCHARGE. SURCHARGE
 AMOUNTS SHALL BE ESTABLISHED BY A RESOLUTION OF THE
 CITY, TOGETHER WITH A SCHEDULE OF RATES AND FEES OF THE
 WWF. IMPOSITION OF INDUSTRIAL WASTE SURCHARGES FOR THE
 RECOVERY OF TREATMENT COSTS DOES NOT REPLACE OR
 SUPERSEDE THE REQUIREMENTS FOR PRETREATMENT FACILITIES,
 SHOULD THEY BE FOUND NECESSARY BY THE CITY.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PW PUBLIC WORKS
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2022-05-23 Time   Rev Time 0.00
Received By   Date 2022-05-23 Time   Sent To  
Notes
2022-05-23 09:52:04NO FURTHER COMMENTS.
  
 MATT HEJAZI
 DEPT. OF PUBLIC WORKS
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-10-04 Cont ID  
Sent By ccole Date 2022-10-04 Time 08:42 Rev Time 0.00
Received By ccole Date 2022-10-04 Time 08:42 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-08-02 Cont ID  
Sent By ccole Date 2022-08-02 Time 12:27 Rev Time 0.00
Received By ccole Date 2022-08-02 Time 12:27 Sent To  
Notes
2022-08-02 12:29:53SIGNATURE REVIEW
 8/2/22
 RESULTS: DENIED.
  
 1) SHEET M001 IS NOT DIGITALLY SIGNED AND SEALED BY THE
 ENGINEER OF RECORD- FL. STATUTE 471.025, AND SECTION
 61G15-23.005 FAC.
  
 SEE FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES
 FOR ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
2022-07-28 10:39:37SHEET M001 WILL REQUIRE THE DESIGNER TO ADD THEIR
 DIGITAL SIGNATURE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-03 Cont ID  
Sent By mpeterso Date 2022-06-03 Time 13:28 Rev Time 0.00
Received By mpeterso Date 2022-06-03 Time 13:27 Sent To  
Notes
2022-06-01 07:48:10DIGITAL SIGNATURE FOR MECHANICAL APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-04 Cont ID  
Sent By rmcphers Date 2022-05-04 Time 11:50 Rev Time 0.00
Received By rmcphers Date 2022-05-04 Time 11:50 Sent To  
Notes
2022-04-26 14:22:44DIGITAL SIGNATURES FOR MECHANICAL APPROVED ME

Review Stop Z ZONING
Rev No 3 Status P Date 2022-08-09 Cont ID  
Sent By asangele Date 2022-08-09 Time 09:22 Rev Time 0.00
Received By asangele Date 2022-08-09 Time 09:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2022-06-10 Cont ID  
Sent By asangele Date 2022-06-10 Time 08:34 Rev Time 0.00
Received By asangele Date 2022-06-10 Time 08:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2022-05-12 Cont ID  
Sent By asangele Date 2022-05-12 Time 09:12 Rev Time 0.00
Received By asangele Date 2022-05-12 Time 09:12 Sent To  
Notes
2022-05-12 09:21:055/12/2022
 FAIL
 PLEASE LABEL ON SURVEY THE EXTERIOR WORK BEING
 COMPLETED TO THE BUIDLING.
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved