Plan Review Details - Permit 22020021
| Plan Review Stops For Permit 22020021 |
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2022-02-28 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-02-28 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
rrossano |
Date |
2022-02-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
rrossano |
Date |
2022-02-23 |
Time |
|
Sent To |
|
|
| Notes |
| 2022-02-23 07:05:19 | PLEASE CONFIRM THAT GREASE TRAP IS ONSITE/NOT IN RIGHT | | | OF WAY. | | | | | | THANKS, | | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | | (561) 246-9525 | | | EMAIL: [email protected] | | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | | STANDARDS-DETAILS | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2022-03-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2022-02-25 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-23 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-16 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-01 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-01 |
Time |
17:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2022-03-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-08 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-08 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-01 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-01 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2022-03-01 17:31:18 | 2ND REVIEW FBC-2020 PLUMBING | | | PERMIT- 22020021 | | | 3/1/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. FAILED CPOMMENTS FROM THE | | | 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN | | | CAPS FOR CLARIFICATION. | | | | | | 2) FAILED. SHEET P1.0 & P1.3: SHOW THE LOCATIONS OF THE | | | SAMPLING PORT ON P1.0, AND INCLUDE THE GREASE | | | INTERCEPTOR AND VENT LINE IN THE RISER DRAWING- SEC. | | | 1003.3.5 FBC P. THE MANUFACTURER RECOMMENDED SAMPLING | | | PORT HAS HAS BEEN REMOVED. PLEASE PROVIDE DATA | | | INDICATING THE REMAINING CLEANOUTS CAN BE USED FOR | | | SAMPLING THE EFFLUENT. | | | | | | 3) FAILED. SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE INTERCEPTOR AND | | | SAMPLING PORT- SEC. 1003.3.5 FBC P. PLEASE NOTE THAT | | | SCHIER RECOMMENDS REINFORCED CONCRETE SLABS FOR BELOW | | | GRADE INSTALLATIONS. THE SPECS SHEETS WERE SUBMITTED | | | BUT NOT THE INSTALLATION INSTRUCTIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2022-02-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-02-18 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-02-18 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2022-02-18 14:16:50 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 22020021 | | | 2/18/2022 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SUBMIT REVISED CIVIL PLANS FOR ENGINEERING | | | REVIEW- SEC. 107.2.1 WPB. | | | | | | 2) SHEET P1.0 & P1.3: SHOW THE LOCATIONS OF THE | | | SAMPLING PORT ON P1.0, AND INCLUDE THE GREASE | | | INTERCEPTOR AND VENT LINE IN THE RISER DRAWING- SEC. | | | 1003.3.5 FBC P. | | | | | | 3) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATION INSTRUCTIONS FOR THE INTERCEPTOR AND | | | SAMPLING PORT- SEC. 1003.3.5 FBC P. PLEASE NOTE THAT | | | SCHIER RECOMMENDS REINFORCED CONCRETE SLABS FOR BELOW | | | GRADE INSTALLATIONS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2022-03-01 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2022-03-01 |
Time |
17:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-02-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-23 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-23 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy