Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-03-02 Cont ID  
Sent By cpuell Date 2022-03-02 Time 13:14 Rev Time 0.00
Received By cpuell Date 2022-03-02 Time 13:14 Sent To  
Notes
2022-03-02 13:15:27WORK IS FOR THE NORTHERN UNIT OF PARCEL
 74434404340000010

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-02-22 Cont ID  
Sent By cpuell Date 2022-02-22 Time 16:47 Rev Time 0.00
Received By cpuell Date 2022-02-22 Time 16:47 Sent To  
Notes
2022-02-22 16:47:56PREVIOUS COMMENTS NOT ADDRESSED:

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-02-03 Cont ID  
Sent By cpuell Date 2022-02-03 Time 14:28 Rev Time 0.00
Received By cpuell Date 2022-02-03 Time 14:28 Sent To  
Notes
2022-02-03 14:32:58SKETCH IS SHOWING THAT THE SCOPE OF WORK IS BEING DONE
 ON TWO PARCELS, THE NORTH UNIT 5311 S DIXIE HWY HAS THE
 PCN OF 74434404340000010 AND 5311 S DIXIE HWY 2 HAS THE
 PCN OF 74434404340000020, PLEASE CONTACT [email protected]
 OR CALL 561-805-6659 TO DISCUSS THE ADDRESSING ISSUES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-02-25 Cont ID  
Sent By jbrooks Date 2022-02-25 Time 12:47 Rev Time 0.00
Received By jbrooks Date 2022-02-25 Time 11:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-02-03 Cont ID  
Sent By jbrooks Date 2022-02-03 Time 10:58 Rev Time 0.00
Received By jbrooks Date 2022-02-03 Time 07:44 Sent To  
Notes
2022-02-03 11:00:16JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL
 FL16718-R8 IS INCOMPLETE, PROVIDE THE FOLLOWING
 ADDITIONAL INFORMATION: EVALUATION REPORT PAGES 1-4 TO
 INCLUDE LIMITATIONS PAGE(S). THE EVALUATION REPORTS CAN
 BE PRINTED FROM THE SUMMARY OF PRODUCTS LOCATED AT THE
 BOTTOM OF THE COVER PAGE. PRINT PAGES 1-4 ONLY.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16718-R8 SYSTEM NO. W-93 DOES NOT MEET THE
 MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17
 FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT
 MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR
 EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED
 ENGINEERED NAILING CALCULATIONS WITH AN APPROVED
 SYSTEM.
 3. FBC EB 706.6 PROVIDE A FLASHING DETAIL DRAWING FOR
 THE EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL
 HEIGHT(S).
 4. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW
 ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF
 SLOPE(S), MEAN ROOF HEIGHT(S). LOW SLOPE ROOFS MUST
 SHOW POSITIVE DRAINAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-03-02 Cont ID  
Sent By cpuell Date 2022-03-02 Time 13:15 Rev Time 0.00
Received By cpuell Date 2022-03-02 Time 06:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-02-25 Cont ID  
Sent By jbrooks Date 2022-02-25 Time 12:47 Rev Time 0.00
Received By jbrooks Date 2022-02-18 Time 07:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-02-03 Cont ID  
Sent By cpuell Date 2022-02-03 Time 14:33 Rev Time 0.00
Received By cpuell Date 2022-02-02 Time 08:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-03-02 Cont ID  
Sent By rmcdouga Date 2022-03-02 Time 08:21 Rev Time 0.00
Received By rmcdouga Date 2022-03-02 Time 08:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-02-25 Cont ID  
Sent By jbrooks Date 2022-02-25 Time 12:47 Rev Time 0.00
Received By jbrooks Date 2022-02-25 Time 12:32 Sent To  
Notes
2022-02-25 12:47:54JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS IS A COPY OF A WET SIGNATURE. PROVIDE
 ORIGINAL DOCUMENTS.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME,
 OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND
 SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  