| Plan Review Stops For Permit 22011278 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2022-02-03 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2022-02-03 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2022-02-03 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2022-02-03 15:11:20 | PRIMARY ADDRESS OK, SUITES INDICATED ON THE DESCRIPTION |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-15 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-15 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-23 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2022-02-24 09:54:59 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-15 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-15 |
Time |
10:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-23 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2022-02-24 10:10:37 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ADDED CONVENIENCE STAIR - IS THE SLAB CUT EXISTING? | | | - PLEASE SHOW THE STRUCTURAL DETAILS FOR THE SLAB CUT | | | AND REPAIR. | | | | | | 2) CONVENIENCE STAIR - PLEASE SHOW THE RISERS TO BE | | | CLOSED OR LESS THAN 4" OPENING PER FBC 1011.5.5.3 SOLID | | | RISERS. | | | RISERS SHALL BE SOLID. | | | | | | EXCEPTIONS: (1) SOLID RISERS ARE NOT REQUIRED FOR | | | STAIRWAYS THAT ARE NOT REQUIRED TO COMPLY WITH SECTION | | | 1009, PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT | | | PERMIT THE PASSAGE OF A SPHERE WITH A DIAMETER OF 4 | | | INCHES (102 MM). | | | | | | 3) CONVENIENCE STAIR - PLEASE PROVIDE A STATEMENT ON | | | THE DRAWINGS THAT THE GLASS IN THE GUARD RAILS COMPLY | | | WITH FBC 2407.1 MATERIALS. | | | GLASS USED IN A HANDRAIL, GUARDRAIL OR GUARD SECTION | | | SHALL BE LAMINATED GLASS CONSTRUCTED OF FULLY TEMPERED | | | OR HEAT-STRENGTHENED GLASS AND SHALL COMPLY WITH | | | CATEGORY II OR CPSC 16 CFR PART 1201 OR CLASS A OF ANSI | | | Z97.1. GLAZING IN RAILING IN-FILL PANELS SHALL BE OF AN | | | APPROVED SAFETY GLAZING MATERIAL THAT CONFORMS TO THE | | | PROVISIONS OF SECTION 2406.1.1. FOR ALL GLAZING TYPES, | | | THE MINIMUM NOMINAL THICKNESS SHALL BE 1/4 INCH (6.4 | | | MM). | | | | | | 4) CONVENIENCE STAIR - PLEASE PROVIDE THE STAIR DETAILS | | | - FRAME TYPE, ATTACHMENTS TO EXISTING STRUCTURE ETC. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-17 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-17 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2022-02-17 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2022-02-17 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2022-02-17 15:40:44 | VOICE AND DATA JLEAHY |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2022-02-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2022-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2022-02-04 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-15 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-08 |
Time |
07:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-03 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2022-02-17 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2022-02-17 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-03-15 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-15 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-17 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-02-17 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-02-17 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2022-02-17 12:36:32 | 1ST REVIEW FBC-2020 MECHANICAL | | | PERMIT-22011278 | | | | | | CODES IN EFFECT: | | | | | | FBC B- FLORIDA BUILDING CODE | | | FBC M- FLORIDA MECHANICAL CODE | | | FBC EC- FLORIDA ENERGY CONSERVATION | | | FBC FG- FLORIDA FUEL GAS | | | FBC EX- FLORIDA EXISTING BUILDING CODE | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M2.01; VAV-16-12 PLEASE SHOW THE CFM?S OF | | | SUPPLY AIR AT THE GRILLES. | | | | | | 2) SHEET M2.01; VAV-16-17; THE DESIGN FLOW IS 2700 BUT | | | THE DRAWING SHOWS 2890. | | | | | | 3) SHEET M2.01; VAV-16-11; THE DESIGN FLOW IS 600 BUT | | | THE DRAWING SHOWS 700. | | | | | | 4) SHEET M2.02; VAV-16-01; THE DESIGN FLOW IS 750 BUT | | | THE DRAWING SHOWS 700. | | | | | | 5) SHEET M2.03; VAV-16-09; THE DESIGN FLOW IS 800 BUT | | | THE DRAWING SHOWS 750. | | | | | | 6) SHEET M2.09; VAV-17-10; THE DESIGN FLOW IS 1040 BUT | | | THE DRAWING SHOWS 1090. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2022-02-10 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2022-02-10 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2022-02-10 |
Time |
14:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2022-03-15 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-15 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-15 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2022-02-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-02-24 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-02-24 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|