Plan Review Details - Permit 22011240
| Plan Review Stops For Permit 22011240 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2022-03-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-31 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-31 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2022-03-31 08:20:49 | THERE IS A RE ROOFING PERMIT (21080306) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2022-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-02 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-02 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2022-03-02 16:03:41 | ROOF TOP EQUIPMENT | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ON THE PROVIDED ENGINEERING FOR THE AC STAND - | | | PLEASE CIRCLE THE STAND DESIGN TO BE USED FROM THE | | | SCHEDULES. | | | | | | 2) PLEASE SHOW THE WIDTH OF THE MECHANICAL UNIT AND THE | | | CLEARANCE FROM THE ROOF TO THE BOTTOM OF THE STAND - | | | FBC 1510.10 MECHANICAL UNITS. | | | ROOF MOUNTED MECHANICAL UNITS SHALL BE MOUNTED ON CURBS | | | RAISED A MINIMUM OF 8 INCHES (203 MM) ABOVE THE ROOF | | | SURFACE, OR WHERE ROOFING MATERIALS EXTEND BENEATH THE | | | UNIT, ON RAISED EQUIPMENT SUPPORTS PROVIDING A MINIMUM | | | CLEARANCE HEIGHT IN ACCORDANCE WITH TABLE 1510.10. | | | | | | 3) PLEASE SHOW THE HEIGHT OF THE BUILDING - NEEDED TO | | | DETERMINE THE WIND DESIGN PRESSURES. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-05 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-03-29 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2022-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-02 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-01-31 |
Time |
06:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2022-04-05 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2022-04-05 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2022-04-05 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-02-09 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-02-09 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2022-02-09 08:26:17 | PLAN DENIED | | | PROVIDE A COMPLETE SET OF CONDENSER STAND SUBMITTALS | | | WITH THE ANCHOR SCHEDULE. | | | PER SECTION 107 FBC 2020. | | | PLAN REVIEW BY HAROLD MOSER | | | HMOSER@WPB .ORG | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2022-03-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-31 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-31 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2022-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2022-03-02 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2022-03-02 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2022-03-02 16:12:05 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) ENGINEERING FROM FRANK BENNARDO P.E. DOES NOT SHOW | | | AS DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED BY THE ENGINEER OR | | | ARCHITECT TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE).- OR - IF YOUR ARCHITECT OR ENGINEER DOES | | | NOT HAVE AN ELECTRONIC OR DIGITAL SIGNATURE - YOU CAN | | | DROP OFF THE ORIGINAL SIGNED AND SEALED | | | DRAWINGS/DOCUMENTS TO THE FRONT DESK IN THE BUILDING | | | DIVISION AT THE CITY HALL. | | | | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2022-02-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2022-02-09 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2022-02-09 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
|