Plan Review Details - Permit 22011153
Plan Review Stops For Permit 22011153
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-05-10 Cont ID  
Sent By cpuell Date 2022-05-10 Time 10:47 Rev Time 0.00
Received By cpuell Date 2022-05-10 Time 10:47 Sent To  
Notes
2022-05-10 10:47:53APPLICANT SENT FLOOR PLAN, UPDATED PARCEL.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-05-07 Cont ID  
Sent By cpuell Date 2022-05-07 Time 09:29 Rev Time 0.00
Received By cpuell Date 2022-05-07 Time 09:29 Sent To  
Notes
2022-05-07 09:32:26INCONSISTENCIES WITH APPLICATION DESCRIPTION AND PLANS,
 PLANS SHOW WALK IN COOLERS FOR UNITS 6 AND 7,
 APPLICATION DESCRIPTION DOES NOT MENTION UNIT 7. UNIT 6
 IS NOT A RECOGNIZED UNIT NUMBER, PLEASE PROVIDE A FLOOR
 PLAN SHOWING EVERY UNIT ON THAT FLOOR. PLEASE RESPOND
 TO [email protected] OR CALL 561-805-6659.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-06-24 Cont ID  
Sent By pvalenti Date 2022-06-24 Time 08:18 Rev Time 0.00
Received By pvalenti Date 2022-06-24 Time 07:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-28 Cont ID  
Sent By jleahy Date 2022-06-28 Time 14:19 Rev Time 0.00
Received By jleahy Date 2022-06-28 Time 14:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-05-26 Cont ID  
Sent By mpeterso Date 2022-05-26 Time 15:24 Rev Time 0.00
Received By mpeterso Date 2022-05-26 Time 15:24 Sent To  
Notes
2022-05-26 15:25:281. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE A BREAKDOWN OF ALL MATERIALS AND LABOR,
 OR, AT YOUR DISCRETION, PROVIDE A SIGNED CONTRACTOR OR
 PROVIDE A REASONABLE VALUE. WPB F.B.C. 109.3
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-06-22 Cont ID  
Sent By cwalker Date 2022-06-22 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-05-09 Cont ID  
Sent By cwalker Date 2022-05-09 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-05-09 10:44:13FIRE COMMENTS:
 PROVIDE DETAIL ON DOORS FOR EXIT CAPACITY, PROPOSED
 OCCUPANT LOAD, DOOR HARDWARE, AND TRAVEL DISTANCE TO
 COMPLY WITH NFPA 101, CHAPTER 7 AND CHAPTER 42.
 C. WALKER, SENIOR FIRE INSPECTOR
 561-804-4762
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-28 Cont ID  
Sent By jleahy Date 2022-06-28 Time 14:22 Rev Time 0.00
Received By jleahy Date 2022-06-21 Time 17:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-26 Cont ID  
Sent By mpeterso Date 2022-05-26 Time 15:25 Rev Time 0.00
Received By mpeterso Date 2022-05-06 Time 08:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-06-23 Cont ID  
Sent By medwards Date 2022-06-23 Time 12:40 Rev Time 0.00
Received By medwards Date 2022-06-23 Time 12:40 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-05-13 Cont ID  
Sent By medwards Date 2022-05-13 Time 09:53 Rev Time 0.00
Received By medwards Date 2022-05-13 Time 09:53 Sent To  
Notes
2022-05-13 09:54:051ST REVIEW FMC
 PERMIT: 22011153
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE APPLICATION IS FOR A WALK-IN COOLER UPGRADE FOR
 1109 OKEECHOBEE RD UNIT 6 WITH THE TYPE OF WORK CHECKED
 IS ALTERATION AND REPAIR. SHEET A-100 CLEARLY SHOWS
 THIS IS 2 NEW COOLERS, ONE IN UNIT6 AND ONE IN UNIT 7.
 REVISE THE PERMIT APPLICATION AND THE VALUE TO REFLECT
 THE 2 UNITS AND THE UNITS THEY WILL BE INSTALLED. FBC
 107.2.1
  
 2) PROVIDE A ROOF DRAWING SHOWING THE LOCATION OF THE
 CONDENSING UNITS AND THE ROOF ACCESS. FBC 107.2.1
  
 3) PROVIDE THE MANUFACTURER?S SPECIFICATIONS FOR THE
 COOLERS. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-06-24 Cont ID  
Sent By pvalenti Date 2022-06-24 Time 08:18 Rev Time 0.00
Received By pvalenti Date 2022-06-24 Time 08:04 Sent To  
Notes
2022-06-23 12:41:32DIGITAL SIGNATURES FOR MECHANICAL APPROVED ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-13 Cont ID  
Sent By medwards Date 2022-05-13 Time 09:54 Rev Time 0.00
Received By medwards Date 2022-05-13 Time 09:54 Sent To  
Notes
2022-05-13 09:55:08THE ARCHITECT MUST DIGITALLY SIGN THE DRAWINGS. FS
 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  